Compressed 3D and 2D digital images versus standard 3D slide film for the evaluation of glaucomatous optic nerve features

被引:3
|
作者
Sandhu, Simrenjeet [1 ]
Rudnisky, Chris [1 ]
Arora, Sourabh [1 ]
Kassam, Faazil [2 ]
Douglas, Gordon [2 ]
Edwards, Marianne C. [1 ]
Verstraten, Karin [2 ]
Wong, Beatrice [3 ]
Damji, Karim F. [1 ]
机构
[1] Univ Alberta, Dept Ophthalmol & Visual Sci, Edmonton, AB, Canada
[2] Univ Calgary, Div Ophthalmol, Dept Surg, Calgary, AB, Canada
[3] Loma Linda Univ, Dept Ophthalmol, Loma Linda, CA 92350 USA
关键词
Glaucoma; Telemedicine; STEREO-PHOTOGRAPHY; PREVALENCE; HEAD;
D O I
10.1136/bjophthalmol-2017-310447
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Synopsis Clinicians can feel confident compressed three-dimensional digital (3DD) and two-dimensional digital (2DD) imaging evaluating important features of glaucomatous disc damage is comparable to the previous gold standard of stereoscopic slide film photography, supporting the use of digital imaging for teleglaucoma applications. Background/aims To compare the sensitivity and specificity of 3DD and 2DD photography with stereo slide film in detecting glaucomatous optic nerve head features. Methods This prospective, multireader validation study imaged and compressed glaucomatous, suspicious or normal optic nerves using a ratio of 16:1 into 3DD and 2DD (1024x1280 pixels) and compared both to stereo slide film. The primary outcome was vertical cup-to-disc ratio (VCDR) and secondary outcomes, including disc haemorrhage and notching, were also evaluated. Each format was graded randomly by four glaucoma specialists. A protocol was implemented for harmonising data including consensus-based interpretation as needed. Results There were 192 eyes imaged with each format. The mean VCDR for slide, 3DD and 2DD was 0.590.20, 0.60 +/- 0.18 and 0.62 +/- 0.17, respectively. The agreement of VCDR for 3DD versus film was =0.781and for 2DD versus film was =0.69. Sensitivity (95.2%), specificity (95.2%) and area under the curve (AUC; 0.953) of 3DD imaging to detect notching were better (p=0.03) than for 2DD (90.5%; 88.6%; AUC=0.895). Similarly, sensitivity (77.8%), specificity (98.9%) and AUC (0.883) of 3DD to detect disc haemorrhage were better (p=0.049) than for 2DD (44.4%; 99.5%; AUC=0.72). There was no difference between 3DD and 2DD imaging in detecting disc tilt (p=0.7), peripapillary atrophy (p=0.16), grey crescent (p=0.1) or pallor (p=0.43), although 3D detected sloping better (p=0.013). Conclusions Both 3DD and 2DD imaging demonstrates excellent reproducibility in comparison to stereo slide film with experts evaluating VCDR, notching and disc haemorrhage. 3DD in this study was slightly more accurate than 2DD for evaluating disc haemorrhage, notching and sloping.
引用
收藏
页码:364 / 368
页数:5
相关论文
共 50 条
  • [41] Capturing 3D macromolecule structure in 2D images
    Kim, Jeong Joo
    TRENDS IN BIOCHEMICAL SCIENCES, 2023, 48 (03) : 305 - 306
  • [42] 3D images created on 2D nanostructured surface
    Pylant, Autum C.
    PHOTONICS SPECTRA, 2017, 51 (09) : 18 - 18
  • [43] From 2D images to 3D face geometry
    Lengagne, R
    Tarel, JP
    Monga, O
    PROCEEDINGS OF THE SECOND INTERNATIONAL CONFERENCE ON AUTOMATIC FACE AND GESTURE RECOGNITION, 1996, : 301 - 306
  • [44] A survey of 2D to 3D conversion technology for film
    Liu, W. (wliu@nlpr.ia.ac.cn), 1600, Institute of Computing Technology (24):
  • [45] Manufacturing of 2D/3D features on NIL Masters
    Rolff, H.
    Sczyrba, M.
    Kristlib, M.
    39TH EUROPEAN MASK AND LITHOGRAPHY CONFERENCE, EMLC 2024, 2024, 13273
  • [46] Face recognition based on 2D and 3D features
    Arca, Stefano
    Lanzarotti, Raffaella
    Lipori, Giuseppe
    KNOWLEDGE-BASED INTELLIGENT INFORMATION AND ENGINEERING SYSTEMS: KES 2007 - WIRN 2007, PT I, PROCEEDINGS, 2007, 4692 : 455 - +
  • [47] VIEWING 3D IMAGES IN 3D
    MAHONEY, DP
    COMPUTER GRAPHICS WORLD, 1995, 18 (03) : 19 - 20
  • [48] 3D mammograms: Are they superior to 2D digital mammograms?
    Cox, Drew
    Nakonechnaya, Kristina
    Otondi, Chrispin
    Wright, Alene
    ANNALS OF SURGICAL ONCOLOGY, 2022, 29 (SUPPL 1) : 156 - 157
  • [49] 2D Versus 3D Total Variation Minimization in Digital Breast Tomosynthesis
    Ertas, Metin
    Akan, Aydin
    Yildirim, Isa
    Dinler, Ali
    Kamasak, Mustafa
    2015 IEEE INTERNATIONAL CONFERENCE ON IMAGING SYSTEMS AND TECHNIQUES (IST) PROCEEDINGS, 2015, : 297 - 300
  • [50] The Mona Lisa effect: 2D versus 3D
    Boyarskaya, E.
    Hecht, H.
    PERCEPTION, 2010, 39 : 176 - 176