Compressed 3D and 2D digital images versus standard 3D slide film for the evaluation of glaucomatous optic nerve features

被引:3
|
作者
Sandhu, Simrenjeet [1 ]
Rudnisky, Chris [1 ]
Arora, Sourabh [1 ]
Kassam, Faazil [2 ]
Douglas, Gordon [2 ]
Edwards, Marianne C. [1 ]
Verstraten, Karin [2 ]
Wong, Beatrice [3 ]
Damji, Karim F. [1 ]
机构
[1] Univ Alberta, Dept Ophthalmol & Visual Sci, Edmonton, AB, Canada
[2] Univ Calgary, Div Ophthalmol, Dept Surg, Calgary, AB, Canada
[3] Loma Linda Univ, Dept Ophthalmol, Loma Linda, CA 92350 USA
关键词
Glaucoma; Telemedicine; STEREO-PHOTOGRAPHY; PREVALENCE; HEAD;
D O I
10.1136/bjophthalmol-2017-310447
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Synopsis Clinicians can feel confident compressed three-dimensional digital (3DD) and two-dimensional digital (2DD) imaging evaluating important features of glaucomatous disc damage is comparable to the previous gold standard of stereoscopic slide film photography, supporting the use of digital imaging for teleglaucoma applications. Background/aims To compare the sensitivity and specificity of 3DD and 2DD photography with stereo slide film in detecting glaucomatous optic nerve head features. Methods This prospective, multireader validation study imaged and compressed glaucomatous, suspicious or normal optic nerves using a ratio of 16:1 into 3DD and 2DD (1024x1280 pixels) and compared both to stereo slide film. The primary outcome was vertical cup-to-disc ratio (VCDR) and secondary outcomes, including disc haemorrhage and notching, were also evaluated. Each format was graded randomly by four glaucoma specialists. A protocol was implemented for harmonising data including consensus-based interpretation as needed. Results There were 192 eyes imaged with each format. The mean VCDR for slide, 3DD and 2DD was 0.590.20, 0.60 +/- 0.18 and 0.62 +/- 0.17, respectively. The agreement of VCDR for 3DD versus film was =0.781and for 2DD versus film was =0.69. Sensitivity (95.2%), specificity (95.2%) and area under the curve (AUC; 0.953) of 3DD imaging to detect notching were better (p=0.03) than for 2DD (90.5%; 88.6%; AUC=0.895). Similarly, sensitivity (77.8%), specificity (98.9%) and AUC (0.883) of 3DD to detect disc haemorrhage were better (p=0.049) than for 2DD (44.4%; 99.5%; AUC=0.72). There was no difference between 3DD and 2DD imaging in detecting disc tilt (p=0.7), peripapillary atrophy (p=0.16), grey crescent (p=0.1) or pallor (p=0.43), although 3D detected sloping better (p=0.013). Conclusions Both 3DD and 2DD imaging demonstrates excellent reproducibility in comparison to stereo slide film with experts evaluating VCDR, notching and disc haemorrhage. 3DD in this study was slightly more accurate than 2DD for evaluating disc haemorrhage, notching and sloping.
引用
收藏
页码:364 / 368
页数:5
相关论文
共 50 条
  • [31] 3D object understanding from 2D images
    Wang, PSP
    INTERNATIONAL SYMPOSIUM ON MULTISPECTRAL IMAGE PROCESSING, 1998, 3545 : 33 - 43
  • [32] Simple points in 2D and 3D binary images
    Klette, G
    COMPUTER ANALYSIS OF IMAGES AND PATTERNS, PROCEEDINGS, 2003, 2756 : 57 - 64
  • [33] Face recognition from 2D and 3D images
    Wang, YJ
    Chua, CS
    Ho, YK
    AUDIO- AND VIDEO-BASED BIOMETRIC PERSON AUTHENTICATION, PROCEEDINGS, 2001, 2091 : 26 - 31
  • [34] Integrated 2D and 3D images for face recognition
    Wang, YJ
    Chua, CS
    Ho, YK
    Ren, Y
    11TH INTERNATIONAL CONFERENCE ON IMAGE ANALYSIS AND PROCESSING, PROCEEDINGS, 2001, : 48 - 53
  • [35] Comparison of 2D and 3D images of fractures in a Vertisol
    Moreau, E
    Velde, B
    Terribile, F
    GEODERMA, 1999, 92 (1-2) : 55 - 72
  • [36] Alignment of multimodality, 2D and 3D breast images
    Grevera, GJ
    Udupa, JK
    MEDICAL IMAGING 2003: IMAGE PROCESSING, PTS 1-3, 2003, 5032 : 1135 - 1143
  • [37] 3D shape reconstruction from 2D images
    Hirano, Daisuke
    Funayama, Yusuke
    Maekawa, Takashi
    Computer-Aided Design and Applications, 2009, 6 (05): : 701 - 710
  • [38] 3D reconstruction of 2D ICT images by Matlab
    Wei Dongbo
    Li Dan
    Tang Qibo
    Xu Haijun
    ISTM/2007: 7TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-7, CONFERENCE PROCEEDINGS, 2007, : 3949 - 3952
  • [39] Research on ERP signal for 2D and 3D images
    Shen, L.-L. (sll@tju.edu.cn), 1600, Editorial Board of Jilin University (43):
  • [40] 2D/3D registration of neonatal brain images
    Vansteenkiste, Ewout
    Vandemeulebroucke, Jef
    Philips, Wilfried
    BIOMEDICAL IMAGE REGISTRATION, PROCEEDINGS, 2006, 4057 : 272 - 279