Compressed 3D and 2D digital images versus standard 3D slide film for the evaluation of glaucomatous optic nerve features

被引:3
|
作者
Sandhu, Simrenjeet [1 ]
Rudnisky, Chris [1 ]
Arora, Sourabh [1 ]
Kassam, Faazil [2 ]
Douglas, Gordon [2 ]
Edwards, Marianne C. [1 ]
Verstraten, Karin [2 ]
Wong, Beatrice [3 ]
Damji, Karim F. [1 ]
机构
[1] Univ Alberta, Dept Ophthalmol & Visual Sci, Edmonton, AB, Canada
[2] Univ Calgary, Div Ophthalmol, Dept Surg, Calgary, AB, Canada
[3] Loma Linda Univ, Dept Ophthalmol, Loma Linda, CA 92350 USA
关键词
Glaucoma; Telemedicine; STEREO-PHOTOGRAPHY; PREVALENCE; HEAD;
D O I
10.1136/bjophthalmol-2017-310447
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Synopsis Clinicians can feel confident compressed three-dimensional digital (3DD) and two-dimensional digital (2DD) imaging evaluating important features of glaucomatous disc damage is comparable to the previous gold standard of stereoscopic slide film photography, supporting the use of digital imaging for teleglaucoma applications. Background/aims To compare the sensitivity and specificity of 3DD and 2DD photography with stereo slide film in detecting glaucomatous optic nerve head features. Methods This prospective, multireader validation study imaged and compressed glaucomatous, suspicious or normal optic nerves using a ratio of 16:1 into 3DD and 2DD (1024x1280 pixels) and compared both to stereo slide film. The primary outcome was vertical cup-to-disc ratio (VCDR) and secondary outcomes, including disc haemorrhage and notching, were also evaluated. Each format was graded randomly by four glaucoma specialists. A protocol was implemented for harmonising data including consensus-based interpretation as needed. Results There were 192 eyes imaged with each format. The mean VCDR for slide, 3DD and 2DD was 0.590.20, 0.60 +/- 0.18 and 0.62 +/- 0.17, respectively. The agreement of VCDR for 3DD versus film was =0.781and for 2DD versus film was =0.69. Sensitivity (95.2%), specificity (95.2%) and area under the curve (AUC; 0.953) of 3DD imaging to detect notching were better (p=0.03) than for 2DD (90.5%; 88.6%; AUC=0.895). Similarly, sensitivity (77.8%), specificity (98.9%) and AUC (0.883) of 3DD to detect disc haemorrhage were better (p=0.049) than for 2DD (44.4%; 99.5%; AUC=0.72). There was no difference between 3DD and 2DD imaging in detecting disc tilt (p=0.7), peripapillary atrophy (p=0.16), grey crescent (p=0.1) or pallor (p=0.43), although 3D detected sloping better (p=0.013). Conclusions Both 3DD and 2DD imaging demonstrates excellent reproducibility in comparison to stereo slide film with experts evaluating VCDR, notching and disc haemorrhage. 3DD in this study was slightly more accurate than 2DD for evaluating disc haemorrhage, notching and sloping.
引用
收藏
页码:364 / 368
页数:5
相关论文
共 50 条
  • [1] HOLES AND GENUS OF 2D AND 3D DIGITAL IMAGES
    LEE, CN
    POSTON, T
    ROSENFELD, A
    CVGIP-GRAPHICAL MODELS AND IMAGE PROCESSING, 1993, 55 (01): : 20 - 47
  • [2] 3D IMAGES WITH 2D FOOTPRINT
    Ferre Ferri, Enrique
    REVISTA SONDA-INVESTIGACION Y DOCENCIA EN ARTES Y LETRAS, 2020, (09): : 73 - 82
  • [3] 3D from Compressed 2D Video
    Ideses, Ianir. A.
    Yaroslavsky, Leonid. P.
    Fishbain, Barak
    Vistuch, Roni
    STEREOSCOPIC DISPLAYS AND VIRTUAL REALITY SYSTEMS XIV, 2007, 6490
  • [4] 3D representation and CNC machining of 2D digital images
    Sood, Sumit
    Duvedi, Ravinder Kumar
    Bedi, Sanjeev
    Mann, Stephen
    46TH SME NORTH AMERICAN MANUFACTURING RESEARCH CONFERENCE, NAMRC 46, 2018, 26 : 10 - 20
  • [5] Comparison of 2D and 3D MRI of the optic and oculomotor nerve anatomy
    Held, P
    Nitz, W
    Seitz, J
    Fründ, R
    Müller, HM
    Haffke, T
    Hees, H
    CLINICAL IMAGING, 2000, 24 (06) : 337 - 343
  • [6] 3D versus 2D/3D shape descriptors:: A comparative study
    Zaharia, T
    Prêteux, F
    IMAGE PROCESSING: ALGORITHMS AND SYSTEMS III, 2004, 5298 : 47 - 58
  • [7] Evaluation of Uterine Anomalies: 3D FRFSE Cube Versus Standard 2D FRFSE
    Agrawal, Garima
    Riherd, Jody M.
    Busse, Reed F.
    Hinshaw, J. Louis
    Sadowski, Elizabeth A.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (06) : W558 - W562
  • [9] Evaluation of the Rotational Alignment Accuracy and Error Using 3D/3D, 2D/3D and 3D Surface Registration
    Kuo, H.
    Ballangrud, A.
    Li, G.
    Lovelock, D.
    Wolthuis, B.
    Della-Biancia, C.
    Berry, S.
    Hunt, M.
    MEDICAL PHYSICS, 2019, 46 (06) : E307 - E308
  • [10] CREATING 3D DRAWING FROM 2D DIGITAL IMAGES WITH PHOTOGRAMMETRY
    Kitagawa, E.
    Sugimachi, T.
    PROCEEDINGS OF THE FIRST INTERNATIONAL CONFERENCE ON SUSTAINABLE URBANIZATION (ICSU 2010), 2010, : 213 - 217