Ultra-high-resolution CT urography: Importance of matrix size and reconstruction technique on image quality

被引:2
|
作者
Nakamoto, Atsushi [1 ]
Hori, Masatoshi [1 ]
Onishi, Hiromitsu [1 ]
Ota, Takashi [1 ]
Fukui, Hideyuki [1 ]
Ogawa, Kazuya [1 ]
Yano, Keigo [1 ]
Tatsumi, Mitsuaki [1 ]
Tomiyama, Noriyuki [1 ]
机构
[1] Osaka Univ, Grad Sch Med, Dept Diagnost & Intervent Radiol, 2-2,Yamadaoka, Suita, Osaka 5650871, Japan
关键词
High-resolution computed tomography; Iterative reconstruction; CT urography; Urinary tract; RADIATION-DOSE REDUCTION; ITERATIVE RECONSTRUCTION; ANGIOGRAPHY; ARTERY;
D O I
10.1016/j.ejrad.2020.109148
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the image quality of CT urography (CTU) obtained with ultra-high-resolution CT (U-HRCT) reconstructed with hybrid iterative reconstruction (IR) and model-based IR algorithms. Method: Forty-eight patients who underwent CTU using the U-HRCT system were enrolled in this retrospective study. Excretory phase images were reconstructed with three protocols: Protocol A: 1024-matrix, 0.25 mm-thickness, and model-based IR; Protocol B: 1024-matrix, 0.25 mm-thickness, and hybrid IR; Protocol C: 512matrix, 0.5 mm-thickness, and model-based IR. Objective image noise and contrast-to-noise ratio (CNR) of the renal pelvis were compared among the protocols. Three-dimensional maximum intensity projection CTU images were generated from each image data set, and image quality was evaluated by two radiologists. Results: Protocol C yielded the lowest objective image noise and highest CNR, whereas Protocol A had highest image noise and lowest CNR (P < 0.01). Regarding the detailed delineation of urinary tract structures on the images, the mean visual score was significantly higher for Protocol A than for Protocols B and C (P < 0.001), and the mean score for subjective image noise was significantly lower for Protocol A than for Protocols B and C (P < 0.001). Conclusions: CTU with a 1024-matrix and model-based IR depicted the structures of the urinary system in the most detail.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] The Importance of Temporal Resolution for Ultra-High-Resolution Coronary Angiography: Evidence From Photon-Counting Detector CT
    Mergen, Victor
    Sartoretti, Thomas
    Cundari, Giulia
    Serifovic, Medina
    Higashigaito, Kai
    Allmendinger, Thomas
    Schmidt, Bernhard
    Flohr, Thomas
    Manka, Robert
    Eberhard, Matthias
    Alkadhi, Hatem
    INVESTIGATIVE RADIOLOGY, 2023, 58 (11) : 767 - 774
  • [32] Diagnostic value of deep learning reconstruction for radiation dose reduction at abdominal ultra-high-resolution CT
    Nakamura, Yuko
    Narita, Keigo
    Higaki, Toru
    Akagi, Motonori
    Honda, Yukiko
    Awai, Kazuo
    EUROPEAN RADIOLOGY, 2021, 31 (07) : 4700 - 4709
  • [33] Diagnostic value of deep learning reconstruction for radiation dose reduction at abdominal ultra-high-resolution CT
    Yuko Nakamura
    Keigo Narita
    Toru Higaki
    Motonori Akagi
    Yukiko Honda
    Kazuo Awai
    European Radiology, 2021, 31 : 4700 - 4709
  • [34] Recent Advances in X-Ray CT - From Ultra-High-Resolution Imaging to AI Reconstruction
    Zbijewski, Wojciech
    MEDICAL PHYSICS, 2021, 48 (06)
  • [35] In vitro evaluation of normal and abnormal lungs with ultra-high-resolution CT
    Ikura, H
    Shimizu, K
    Ikezoe, J
    Nagareda, T
    Yagi, N
    JOURNAL OF THORACIC IMAGING, 2004, 19 (01) : 8 - 15
  • [36] Ultra-high-resolution CT angiography of the artery of Adamkiewicz: a feasibility study
    Yoshioka, Kunihiro
    Tanaka, Ryoichi
    Takagi, Hidenobu
    Ueyama, Yuta
    Kikuchi, Kei
    Chiba, Takuya
    Arakita, Kazumasa
    Schuijf, Joanne D.
    Saito, Yasuo
    NEURORADIOLOGY, 2018, 60 (01) : 109 - 115
  • [37] Ultra-high-resolution CT angiography of the artery of Adamkiewicz: a feasibility study
    Kunihiro Yoshioka
    Ryoichi Tanaka
    Hidenobu Takagi
    Yuta Ueyama
    Kei Kikuchi
    Takuya Chiba
    Kazumasa Arakita
    Joanne D. Schuijf
    Yasuo Saito
    Neuroradiology, 2018, 60 : 109 - 115
  • [38] Ultra-high-resolution photon-counting CT: "Plus Ultra" in lung imaging?
    Milos, Ruxandra-Iulia
    EUROPEAN RADIOLOGY, 2024, 34 (03) : 1893 - 1894
  • [39] Ultra-high-resolution photon-counting CT: “Plus Ultra” in lung imaging?
    Ruxandra-Iulia Milos
    European Radiology, 2024, 34 : 1893 - 1894
  • [40] Importance of the heart rate in ultra-high-resolution coronary CT angiography with 0.35 s gantry rotation time
    Tsukasa Kojima
    Takashi Shirasaka
    Yuzo Yamasaki
    Masatoshi Kondo
    Hiroshi Hamasaki
    Ryoji Mikayama
    Yuki Sakai
    Toyoyuki Kato
    Akihiro Nishie
    Kousei Ishigami
    Hidetake Yabuuchi
    Japanese Journal of Radiology, 2022, 40 : 781 - 790