Fully discharging phases - A new approach to biphasic waveforms for external defibrillation

被引:8
|
作者
Yamanouchi, Y
Brewer, JE
Olson, KF
Mowrey, KA
Mazgalev, TN
Wilkoff, BL
Tchou, PJ
机构
[1] Cleveland Clin Fdn, Dept Cardiol F15, Clin Cardiac Electrophysiol, Cleveland, OH 44195 USA
[2] SurVivaLink Corp, Minneapolis, MN USA
关键词
defibrillation; death; sudden; ventricles;
D O I
10.1161/01.CIR.100.8.826
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Phase-2 voltage and maximum pulse width are dependent on phase-1 pulse characteristics in a single-capacitor biphasic waveform. The use of 2 separate output capacitors avoids these limitations and may allow waveforms with lower defibrillation thresholds. A previous report also suggested that the optimal tilt may be >70%. This study was designed to determine an optimal biphasic waveform by use of a combination of 2 separate and fully (95% tilt) discharging capacitors. Methods and Results-We performed 2 external defibrillation studies in a pig ventricular fibrillation model. In group I, 9 waveforms from a combination of 3 phase-1 capacitor values (30, 60, and 120 mu F) and 3 phase-2 capacitor values (0=monophasic, 1/3, and 1.0 times the phase-1 capacitor) were tested. Biphasic waveforms with phase-2 capacitors of 1/3 times that of phase 1 provided the highest defibrillation efficacy (stored energy and voltage) compared with corresponding monophasic and biphasic waveforms with the same capacitors in both phases except for waveforms with. a 30-mu F phase-1 capacitor. In group 2, 10 biphasic waveforms from a combination of 2 phase-1 capacitor values (30 and 60 mu F) and 5 phase-2 capacitor values (10, 20, 30, 40, and 50 mu F) were tested. In this range, phase-2 capacitor size was more critical for the 30-mu F phase-1 than for the 60-mu F phase-1 capacitor. The optimal combinations of fully discharging capacitors for defibrillation were 60/20 and 60/30 mu F Conclusions-Phase-2 capacitor size plays an important role in reducing defibrillation energy in biphasic waveforms when 2 separate and fully discharging capacitors are used.
引用
收藏
页码:826 / 831
页数:6
相关论文
共 50 条
  • [31] Correlation of the defibrillation threshold and the upper limit of vulnerability for multipulse biphasic waveforms
    Reighard, Jennifer
    Sweeney, James
    Dosdall, Derek
    Brandon, Tedd
    2000, Am Inst Phys, Woodbury, NY, United States (28)
  • [32] A comparison of biphasic and monophasic shocks for external defibrillation of humans
    Herre, JM
    Higgins, SL
    Epstein, AE
    Greer, S
    Friedman, PL
    Gleva, MJ
    Porterfield, JG
    Chapman, FW
    Finkel, ES
    Schmitt, PW
    Nova, RC
    Greene, HL
    CIRCULATION, 1998, 98 (17) : 173 - 173
  • [33] Immediate termination of fibrillation is more likely with biphasic truncated exponential versus monophasic damped sine waveforms used for external defibrillation
    Tovar, OH
    Snyder, DE
    George, AR
    Jones, JL
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (05) : 336A - 336A
  • [34] The influence of ventricular fibrillation duration on defibrillation efficacy using biphasic waveforms in humans
    Windecker, S
    Ideker, RE
    Plumb, VJ
    Kay, GN
    Walcott, GP
    Epstein, AE
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 33 (01) : 33 - 38
  • [35] COMPARISON OF THE INTERNAL DEFIBRILLATION THRESHOLDS FOR MONOPHASIC AND DOUBLE AND SINGLE CAPACITOR BIPHASIC WAVEFORMS
    KAVANAGH, KM
    TANG, ASL
    ROLLINS, DL
    SMITH, WM
    IDEKER, RE
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (05) : 1343 - 1349
  • [36] The effects of phase duration on defibrillation success of dual time constant biphasic waveforms
    Shan, Yi
    Ristagno, Giuseppe
    Fuller, Marc
    Sun, Shijie
    Li, Yongqin
    Weil, Max Harry
    Russell, James
    Tang, Wanchun
    RESUSCITATION, 2010, 81 (02) : 236 - 241
  • [37] Effect of changing capacitors between phases of a biphasic defibrillation shock
    Walcott, GP
    Rollins, DL
    Smith, WM
    Ideker, RE
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1996, 19 (06): : 945 - 954
  • [38] Multicenter study of principles-based waveforms for external defibrillation
    Bain, AC
    Swerdlow, CD
    Love, CJ
    Ellenbogen, KA
    Deering, TF
    Brewer, JE
    Augostini, RS
    Tchou, PJ
    ANNALS OF EMERGENCY MEDICINE, 2001, 37 (01) : 5 - 12
  • [39] Effect of biphasic waveforms on transvenous defibrillation thresholds in patients with coronary artery disease
    Olsovsky, MR
    Hodgson, DM
    Shorofsky, SR
    Kavesh, NG
    Gold, MR
    AMERICAN JOURNAL OF CARDIOLOGY, 1997, 80 (08): : 1098 - &
  • [40] The influence of ventricular fibrillation duration on the defibrillation threshold using biphasic waveforms in humans
    Windecker, S
    Ideker, RE
    Kay, GN
    Plumb, VJ
    Epstein, AE
    CIRCULATION, 1997, 96 (08) : 3241 - 3241