摘要
Background-Phase-2 voltage and maximum pulse width are dependent on phase-1 pulse characteristics in a single-capacitor biphasic waveform. The use of 2 separate output capacitors avoids these limitations and may allow waveforms with lower defibrillation thresholds. A previous report also suggested that the optimal tilt may be >70%. This study was designed to determine an optimal biphasic waveform by use of a combination of 2 separate and fully (95% tilt) discharging capacitors. Methods and Results-We performed 2 external defibrillation studies in a pig ventricular fibrillation model. In group I, 9 waveforms from a combination of 3 phase-1 capacitor values (30, 60, and 120 mu F) and 3 phase-2 capacitor values (0=monophasic, 1/3, and 1.0 times the phase-1 capacitor) were tested. Biphasic waveforms with phase-2 capacitors of 1/3 times that of phase 1 provided the highest defibrillation efficacy (stored energy and voltage) compared with corresponding monophasic and biphasic waveforms with the same capacitors in both phases except for waveforms with. a 30-mu F phase-1 capacitor. In group 2, 10 biphasic waveforms from a combination of 2 phase-1 capacitor values (30 and 60 mu F) and 5 phase-2 capacitor values (10, 20, 30, 40, and 50 mu F) were tested. In this range, phase-2 capacitor size was more critical for the 30-mu F phase-1 than for the 60-mu F phase-1 capacitor. The optimal combinations of fully discharging capacitors for defibrillation were 60/20 and 60/30 mu F Conclusions-Phase-2 capacitor size plays an important role in reducing defibrillation energy in biphasic waveforms when 2 separate and fully discharging capacitors are used.
引用
收藏
页码:826 / 831
页数:6
相关论文
共 50 条
  • [21] Biphasic waveforms prevent the chronic rise of transvenous defibrillation thresholds
    Gold, MR
    Kavesh, NG
    Peters, RW
    Shorofsky, SR
    CIRCULATION, 1996, 94 (08) : 1869 - 1869
  • [22] Porcine defibrillation thresholds with chopped biphasic truncated exponential waveforms
    Sullivan, Joseph L.
    Melnick, Sharon B.
    Chapman, Fred W.
    Walcott, Gregory P.
    RESUSCITATION, 2007, 74 (02) : 325 - 331
  • [23] HUMAN DEFIBRILLATION THRESHOLDS WITH BIPHASIC WAVEFORMS AND CONTOURED EPICARDIAL PATCHES
    BARIN, ES
    ELSTOB, JE
    HAKIM, MG
    REES, GM
    CALFEE, RV
    EDMONDSON, SJ
    NATHAN, AW
    BRITISH HEART JOURNAL, 1988, 59 (05): : 623 - 623
  • [24] Surgical open-chest ventricular defibrillation: Triphasic waveforms are superior to biphasic waveforms
    Zhang, Y
    Boddicker, KA
    Davies, LR
    Jones, JL
    Kerber, RE
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2004, 27 (07): : 941 - 948
  • [25] Comparison of monophasic and truncated exponential biphasic waveforms for external defibrillation following short and long durations of ventricular fibrillation
    Walcott, GP
    Elabbady, T
    Chapman, F
    Jones, J
    Johnson, JA
    Spruell, R
    Ideker, RE
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 403A - 403A
  • [26] Internal atrial defibrillation by using a new single atrial lead system and evaluation of two new biphasic waveforms
    Heisel, A
    Jung, J
    Schubert, B
    Kollner, V
    Michel, U
    PACEMAKER LEADS 1997, 1997, : 567 - 572
  • [27] DEFIBRILLATION THRESHOLDS USING BIPHASIC WAVEFORMS AND CONTOURED EPICARDIAL PATCHES IN MAN
    NATHAN, AW
    BARIN, ES
    ELSTOB, JE
    HAKIM, MG
    REES, GM
    CALFEE, RV
    EDMONDSON, SJ
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (04): : 498 - 498
  • [28] Pediatric transthoracic defibrillation: biphasic versus monophasic waveforms in an experimental model
    Clark, CB
    Zhang, Y
    Davies, LR
    Karlsson, G
    Kerber, RE
    RESUSCITATION, 2001, 51 (02) : 159 - 163
  • [29] Pediatric defibrillation: Biphasic vs. monophasic waveforms in an experimental model
    Clark, CB
    Davies, LR
    Kerber, RE
    CIRCULATION, 1999, 100 (18) : 90 - 90
  • [30] Comparison of three biphasic defibrillation waveforms: Gurvich waveform is more efficient
    Qu, F
    Nikolski, VP
    Wollenzier, BR
    Efimov, IR
    SECOND JOINT EMBS-BMES CONFERENCE 2002, VOLS 1-3, CONFERENCE PROCEEDINGS: BIOENGINEERING - INTEGRATIVE METHODOLOGIES, NEW TECHNOLOGIES, 2002, : 1439 - 1440