Chemiluminescence immunoassay for a nonionic surfactant using a compact disc-type microfluidic platform

被引:3
|
作者
Guo, Shuai [1 ]
Nakano, Koji [1 ]
Nakajima, Hizuru [2 ]
Uchiyama, Katsumi [2 ]
Hemmi, Akihide [3 ]
Yamasaki, Yoshikazu [4 ]
Morooka, Shigeharu [4 ]
Ishimatsu, Ryoichi [1 ]
Imato, Toshihiko [1 ]
机构
[1] Kyushu Univ, Grad Sch Engn, Dept Appl Chem, Fukuoka 8190395, Japan
[2] Tokyo Metropolitan Univ, Grad Sch Engn, Dept Appl Chem, Tokyo 1920397, Japan
[3] Mebius Adv Technol Ltd, Tokyo 1670042, Japan
[4] Fukuoka Univ, Fac Engn, Dept Chem Engn, Fukuoka 8140180, Japan
关键词
bioanalytical methods; binding constants; chemiluminescence immunoassay; compact disc (CD)-type microfluidic platform; enzyme chemistry; green chemistry; magnetic microbeads; optical emission spectroscopy; PERFORMANCE LIQUID-CHROMATOGRAPHY; LINKED-IMMUNOSORBENT-ASSAY; WASTE-WATER TREATMENT; ALKYLPHENOL POLYETHOXYLATES; MASS SPECTROMETRY; DEGRADATION-PRODUCTS; LINEAR ALKYLBENZENESULFONATES; WHOLE-BLOOD; NONYLPHENOL; EXTRACTION;
D O I
10.1351/PAC-CON-11-10-10
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A simple and pump-free chemiluminescence immunoassay based on a compact disc (CD)-type microfluidic platform for the determination of alkylphenol polyethoxylates (APnEOs) is described. The method is based on a competitive immunoreaction of the anti-APnEOs antibody immobilized on the magnetic microbeads between APnEOs and horseradish peroxidase (HRP)-labeled APnEOs in the sample solution. The luminol solution containing H2O2 and enhancer is caused to flow from one reservoir in the platform to another by appropriate adjustment of the speed of the rotation of the disc. The detection limit was similar to that reported in our previous paper, i.e., 10 ppb according to IC80.
引用
收藏
页码:2027 / 2043
页数:17
相关论文
共 50 条
  • [41] Simple, rapid, and accurate malaria diagnostic platform using microfluidic-based immunoassay of Plasmodium falciparum lactate dehydrogenase
    Lee, Wang Sik
    Kang, Taejoon
    Kwak, Kyung Jin
    Park, Kyoungsook
    Yi, So Yeon
    Lee, Ui Jin
    Shin, Yong Beom
    Jeong, Jinyoung
    NANO CONVERGENCE, 2020, 7 (01)
  • [42] Simple, rapid, and accurate malaria diagnostic platform using microfluidic-based immunoassay of Plasmodium falciparum lactate dehydrogenase
    Wang Sik Lee
    Taejoon Kang
    Kyung Jin Kwak
    Kyoungsook Park
    So Yeon Yi
    Ui Jin Lee
    Yong Beom Shin
    Jinyoung Jeong
    Nano Convergence, 7
  • [43] A compact microfluidic laser-induced fluorescence immunoassay system using avalanche photodiode for rapid detection of alpha-fetoprotein
    Zheng, Chaowen
    Dai, Peng
    You, Hui
    Xian, Zhaokun
    Su, Wenyun
    Wu, Shixiong
    Xing, Dong
    Sun, Cuimin
    ANALYTICAL SCIENCES, 2024, 40 (07) : 1239 - 1248
  • [44] Evaluation of Coconut Oil-based Emulsion Stability Using Tween-Span Type Nonionic Mixed Surfactant
    Hong, Seheum
    Zhu, Kaiyang
    Zuo, Chengliang
    Lee, Seung Bum
    APPLIED CHEMISTRY FOR ENGINEERING, 2019, 30 (04): : 453 - 459
  • [45] Evaluation of 99th percentile value of a chemiluminescence enzyme immunoassay (CLEIA) for cTnI using the automated AIA-CL2400 platform
    Masotti, Silvia
    Musetti, Veronica
    Aloe, Rosalia
    Rizzardi, Sara
    Dittadi, Ruggero
    Carrozza, Cinzia
    Perrone, Marco
    Fasano, Tommaso
    de Santis, Antonio
    Prontera, Concetta
    Guiotto, Cristina
    Clerico, Aldo
    CLINICA CHIMICA ACTA, 2019, 496 : 45 - 47
  • [46] Highly sensitive chemiluminescence immunoassay on chitosan membrane modified paper platform using TiO2 nanoparticles/multiwalled carbon nanotubes as label
    Li, Weiping
    Ge, Shenguang
    Wang, Shoumei
    Yan, Mei
    Ge, Lei
    Yu, Jinghua
    LUMINESCENCE, 2013, 28 (04) : 496 - 502
  • [47] Finite element method-based modelling of flow rate and temperature distribution in an oil-filled disc-type winding transformer using COMSOL multiphysics
    Das, Anu Kumar
    Chatterjee, Saibal
    IET ELECTRIC POWER APPLICATIONS, 2017, 11 (04) : 664 - 673
  • [48] A STUDY OF THE AQUEOUS DEGREASING OF AUSTRALIAN WOOLLY SHEEPSKINS USING NONIONIC SURFACTANTS .1. EFFECT OF SURFACTANT TYPE AND TREATMENT CONDITIONS
    WATERS, PJ
    PRICE, SM
    JOURNAL OF THE SOCIETY OF LEATHER TECHNOLOGISTS AND CHEMISTS, 1991, 75 (06): : 197 - 202
  • [49] Evaluation of an antibody avidity index method for detecting recent human immunodeficiency virus type 1 infection using an automated chemiluminescence immunoassay
    Fernandez, Gema
    Manzardo, Christian
    Montoliu, Alexandra
    Campbell, Colin
    Fernandez, Gregorio
    Casabona, Jordi
    Miro, Jose Maria
    Matas, Lurdes
    Rivaya, Belen
    Gonzalez, Victoria
    ENFERMEDADES INFECCIOSAS Y MICROBIOLOGIA CLINICA, 2015, 33 (04): : 238 - 242
  • [50] OPTICAL PICKUP FOR COMPACT DISC PLAYER USING COMPUTER-GENERATED HOLOGRAM AND REFLECTION-TYPE GRATING
    LEE, CW
    CHUNG, CS
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 1993, 32 (11B): : 5451 - 5452