Chemiluminescence immunoassay for a nonionic surfactant using a compact disc-type microfluidic platform

被引:3
|
作者
Guo, Shuai [1 ]
Nakano, Koji [1 ]
Nakajima, Hizuru [2 ]
Uchiyama, Katsumi [2 ]
Hemmi, Akihide [3 ]
Yamasaki, Yoshikazu [4 ]
Morooka, Shigeharu [4 ]
Ishimatsu, Ryoichi [1 ]
Imato, Toshihiko [1 ]
机构
[1] Kyushu Univ, Grad Sch Engn, Dept Appl Chem, Fukuoka 8190395, Japan
[2] Tokyo Metropolitan Univ, Grad Sch Engn, Dept Appl Chem, Tokyo 1920397, Japan
[3] Mebius Adv Technol Ltd, Tokyo 1670042, Japan
[4] Fukuoka Univ, Fac Engn, Dept Chem Engn, Fukuoka 8140180, Japan
关键词
bioanalytical methods; binding constants; chemiluminescence immunoassay; compact disc (CD)-type microfluidic platform; enzyme chemistry; green chemistry; magnetic microbeads; optical emission spectroscopy; PERFORMANCE LIQUID-CHROMATOGRAPHY; LINKED-IMMUNOSORBENT-ASSAY; WASTE-WATER TREATMENT; ALKYLPHENOL POLYETHOXYLATES; MASS SPECTROMETRY; DEGRADATION-PRODUCTS; LINEAR ALKYLBENZENESULFONATES; WHOLE-BLOOD; NONYLPHENOL; EXTRACTION;
D O I
10.1351/PAC-CON-11-10-10
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A simple and pump-free chemiluminescence immunoassay based on a compact disc (CD)-type microfluidic platform for the determination of alkylphenol polyethoxylates (APnEOs) is described. The method is based on a competitive immunoreaction of the anti-APnEOs antibody immobilized on the magnetic microbeads between APnEOs and horseradish peroxidase (HRP)-labeled APnEOs in the sample solution. The luminol solution containing H2O2 and enhancer is caused to flow from one reservoir in the platform to another by appropriate adjustment of the speed of the rotation of the disc. The detection limit was similar to that reported in our previous paper, i.e., 10 ppb according to IC80.
引用
收藏
页码:2027 / 2043
页数:17
相关论文
共 50 条
  • [31] Ultrasensitive detection of porcine circovirus type 2 using gold(III) enhanced chemiluminescence immunoassay
    Zhang, Huimin
    Li, Wentao
    Sheng, Zonghai
    Han, Heyou
    He, Qigai
    ANALYST, 2010, 135 (07) : 1680 - 1685
  • [32] N-Glycan profile analysis of transferrin using a microfluidic compact disc and MALDI-MS
    Alessandro Quaranta
    Anna Sroka-Bartnicka
    Erik Tengstrand
    Gunnar Thorsén
    Analytical and Bioanalytical Chemistry, 2016, 408 : 4765 - 4776
  • [33] N-Glycan profile analysis of transferrin using a microfluidic compact disc and MALDI-MS
    Quaranta, Alessandro
    Sroka-Bartnicka, Anna
    Tengstrand, Erik
    Thorsen, Gunnar
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (17) : 4765 - 4776
  • [34] Analysis of Spoof Surface Plasmon Polaritons in a Metal Disc-Type Splitter Using the Cylindrical HIE-FDTD Method
    Shibayama, Jun
    Ito, Masato
    Yamauchi, Junji
    Nakano, Hisamatsu
    2018 IEEE MTT-S INTERNATIONAL CONFERENCE ON NUMERICAL ELECTROMAGNETIC AND MULTIPHYSICS MODELING AND OPTIMIZATION (NEMO), 2018,
  • [35] An automatic and smart platform for rapid detection of cadmium and lead simultaneously in rice using triple-amplified chemiluminescence immunoassay
    Tian, Wei
    Wang, Songxue
    Li, Xiaomeng
    Zhou, Minghui
    Wu, Yanxiang
    Zhang, Jieqiong
    Chen, Xi
    FOOD CHEMISTRY, 2024, 437
  • [36] Evaluation of analytical performance of a chemiluminescence enzyme immunoassay (CLEIA) for cTnI using the automated AIA-CL2400 platform
    Masotti, Silvia
    Musetti, Veronica
    Prontera, Concetta
    Storti, Simona
    Passino, Claudio
    Zucchelli, Giancarlo
    Clerico, Aldo
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2018, 56 (07) : E174 - E176
  • [37] An automatic and smart platform for rapid detection of cadmium and lead simultaneously in rice using triple-amplified chemiluminescence immunoassay
    Tian, Wei
    Wang, Songxue
    Li, Xiaomeng
    Zhou, Minghui
    Wu, Yanxiang
    Zhang, Jieqiong
    Chen, Xi
    Food Chemistry, 2024, 437
  • [38] Identification of Novel Multiple Biomarkers for the Early Diagnosis of Ovarian Serous Carcinoma Using a Microfluidic Immunoassay Platform.
    Han, Chanhee
    Bellone, Stefania
    Altwerger, Gary
    Menderes, Gulden
    Santin, Alessandro D.
    Siegel, Eric
    REPRODUCTIVE SCIENCES, 2018, 25 : 285A - 285A
  • [39] Measurement of rock fracture toughness under modes I and II and mixed-mode conditions by using disc-type specimens
    Chang, SH
    Lee, CI
    Jeon, S
    ENGINEERING GEOLOGY, 2002, 66 (1-2) : 79 - 97
  • [40] A compact multifunctional microfluidic platform for exploring cellular dynamics in real-time using electrochemical detection
    Zor, K.
    Heiskanen, A.
    Caviglia, C.
    Vergani, M.
    Landini, E.
    Shah, F.
    Carminati, M.
    Martinez-Serrano, A.
    Ramos Moreno, T.
    Kokaia, M.
    Benayahu, D.
    Keresztes, Zs.
    Papkovsky, D.
    Wollenberger, U.
    Svendsen, W. E.
    Dimaki, M.
    Ferrari, G.
    Raiteri, R.
    Sampietro, M.
    Dufva, M.
    Emneus, J.
    RSC ADVANCES, 2014, 4 (109) : 63761 - 63771