Characteristics and factors associated with intraocular lens tilt and decentration after cataract surgery

被引:52
|
作者
Chen, Xiaoyun [1 ]
Gu, Xiaoxun [1 ]
Wang, Wei [1 ]
Xiao, Wei [1 ]
Jin, Guangming [1 ]
Wang, Lanhua [1 ]
Dai, Ye [1 ]
Zhang, Enen [1 ]
Ruan, Xiaoting [1 ]
Liu, Zhenzhen [1 ]
Luo, Lixia [1 ]
Liu, Yizhi [1 ]
机构
[1] Sun Yat Sen Univ, Zhongshan Ophthalm Ctr, State Key Lab Ophthalmol, Guangzhou, Guangdong, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
CAPSULAR BAG PERFORMANCE; ROTATIONAL STABILITY; ABERRATION; POSITION; 1-PIECE; SIZE;
D O I
10.1097/j.jcrs.0000000000000219
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To analyze the characteristics and factors associated with intraocular lens (IOL) bit and decentration after uneventful phacoemulsification with IOL implantation. Setting: Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China. Design: Cross-sectional study. Methods: All patients underwent a general ophthalmologic examination and anterior segment photography. IOL tilt and decentration were measured with a second-generation anterior segment optical coherence tomography (Casia2). Univariate and multivariate regression analyses were performed to assess the association between IOL bit and decentration with ocular biometric and systemic parameters, and the visual acuity. Results: A total of 196 eyes of 196 patients were enrolled in this study. IOLs showed a mean tilt of 4.8 degrees toward the inferotemporal direction, and the mean decentration was 0.21 mm. Both eyes presented a mirror symmetry relationship. Twenty-two eyes (11.22%) had a tilt greater than 7 degrees, and 21 eyes (10.72%) had a decentration more than 0.4 mm. Multivariate regression analysis showed previous pars plane vitrectomy (PPV) and short axial length (AL) were associated with greater IOL tilt (P = .014 and P < .001). In addition, long AL, thicker lens, and less capsulorhexis-OL overlap were positively correlated with decentration (P < .001, P = .029, and P = .026). Corrected cstanoe visual acuity did not directly correlate with IOL tilt and decentration (P = .417 and P = .550). Conclusions: PPV history and short AL were associated with greater IOL tilt, whereas longer AL, thicker lens, and overlarge capsulorhexis contribute to greater decentration. Implantation of toric and multifocal IOLs in these patients should be cautious. Copyright (C) 2020 Published by Wolters Kluwer on behalf of ASCRS and ESCRS
引用
收藏
页码:1126 / 1131
页数:6
相关论文
共 50 条
  • [11] Effect of a capsular tension ring on prevention of intraocular lens decentration and tilt and on anterior capsule contraction after cataract surgery
    Anselm Jünemann
    Ursula Schlötzer-Schrehardt
    Gottfried O. H. Naumann
    Japanese Journal of Ophthalmology, 2009, 53 : 288 - 288
  • [12] Distributions of crystalline lens tilt and decentration and associated factors in age-related cataract
    Chen, Xiaoyun
    Gu, Xiaoxun
    Wang, Wei
    Jin, Guangming
    Wang, Lanhua
    Zhang, Enen
    Xu, Jingmin
    Liu, Zhenzhen
    Luo, Lixia
    Liu, Yizhi
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (10): : 1296 - 1301
  • [13] Intraocular lens tilt and decentration after implantation in eyes with glaucoma
    Hayashi, K
    Hayashi, H
    Nakao, F
    Hayashi, F
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1999, 25 (11): : 1515 - 1520
  • [14] Assessment of intraocular lens tilt and decentration after femtosecond laser-assisted and conventional cataract surgery at 12 months and beyond
    Kim, Bia Z.
    Lee, Hayoung
    Jeon, Yoo Young
    Eah, Kyu Sang
    Park, Nahyun
    Chung, Ho Seok
    Kim, Jae Yong
    Tchah, Hungwon
    Lee, Hun
    BMC OPHTHALMOLOGY, 2024, 24 (01)
  • [15] Impact of intraocular lens characteristics on intraocular lens dislocation after cataract surgery
    Mayer-Xanthaki, Christoph Fidel
    Pregartner, Gudrun
    Hirnschall, Nino
    Falb, Thomas
    Sommer, Michael
    Findl, Oliver
    Wedrich, Andreas
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2021, 105 (11) : 1510 - 1514
  • [16] Effect of a capsular tension ring on intraocular lens decentration and tilting after cataract surgery
    Lee, DH
    Shin, SC
    Joo, CK
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (05): : 843 - 846
  • [17] Determinants of crystalline lens tilt and decentration: Optimizing cataract surgery outcomes
    Gautam, Megha
    Singh, Priti
    Nyodu, Richa
    Sharma, Bhavana
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2023, 71 (03) : 769 - 770
  • [18] Analysis of intraocular lens tilt and decentration after cataract surgery in eyes with high myopia using the anterior segment optical coherence tomography
    Jeon, Yoo Young
    Park, Nahyun
    Lee, Hayoung
    Eah, Kyu Sang
    Han, Jeewon
    Chung, Ho Seok
    Kim, Jae Yong
    Lee, Hun
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [19] Capsular phimosis with intraocular lens tilt and decentration
    Chee, Soon-Phaik
    Dick, H. Burkhard
    Masket, Samuel
    Beltz, Jacqueline
    Vajpayee, Rasik B.
    Yeu, Elizabeth
    Zhu, Dagny
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2023, 49 (10): : 1073 - 1077
  • [20] Anterior capsule contraction and intraocular lens decentration and tilt after hydrogel lens implantation
    Hayashi, K
    Hayashi, H
    Nakao, F
    Hayashi, F
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2001, 85 (11) : 1294 - 1297