Experimental investigation on water quality standard of Yangtze River water source heat pump

被引:3
|
作者
Qin, Zenghu [1 ]
Tong, Mingwei [1 ]
Kun, Lin [2 ]
机构
[1] Chongqing Univ, Minist Educ, Key Lab Low Grade Energy Utilizat Technol & Syst, Chongqing 400030, Peoples R China
[2] Guangdong Chigo Air Conditioner Co Ltd, Guangzhou 528244, Guangdong, Peoples R China
关键词
coefficient of performance; fouling resistance; heat capacity; water quality; Yangtze River water heat pump; AIR-CONDITIONING SYSTEM; INDEX;
D O I
10.2166/wst.2012.294
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Due to the surface water in the upper reaches of Yangtze River in China containing large amounts of silt and algae, high content of microorganisms and suspended solids, the water in Yangtze River cannot be used for cooling a heat pump directly. In this paper, the possibility of using Yangtze River, which goes through Chongqing, a city in southwest China, as a heat source-sink was investigated. Water temperature and quality of the Yangtze River in the Chongqing area were analyzed and the performance of water source heat pump units in different sediment concentrations, turbidity and algae material conditions were tested experimentally, and the water quality standards, in particular surface water conditions, in the Yangtze River region that adapt to energy-efficient heat pumps were also proposed. The experimental results show that the coefficient of performance heat pump falls by 3.73% to the greatest extent, and the fouling resistance of cooling water in the heat exchanger increases up to 25.6% in different water conditions. When the sediment concentration and the turbidity in the river water are no more than 100 g/m(3) and 50 NTU respectively, the performance of the heat pump is better, which can be used as a suitable river water quality standard for river water source heat pumps.
引用
收藏
页码:1103 / 1109
页数:7
相关论文
共 50 条
  • [41] Experimental study on CO 2 air source heat pump water heater
    Chen Q.
    Tong Y.
    Zhu Z.-J.
    Tang L.-M.
    Chen G.-M.
    Li J.-J.
    Chen, G.-M. (gmchen@zju.edu.cn), 1600, Zhejiang University (46): : 610 - 615
  • [42] System optimization and experimental research on air source heat pump water heater
    Zhang, J.
    Wang, R. Z.
    Wu, J. Y.
    APPLIED THERMAL ENGINEERING, 2007, 27 (5-6) : 1029 - 1035
  • [43] Study on the Effects of Cold Discharge of Lake Water Source Heat Pump Systems on Lake Water Quality
    Huang, Xiang-Yang
    Zhou, Jian
    ICEET: 2009 INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENT TECHNOLOGY, VOL 2, PROCEEDINGS, 2009, : 791 - 794
  • [44] Experimental Investigation of A Heat Storage Solar Water Heater-Water/Air Source Heat Pump Double Stage Coupling Capillary Network Heating System
    Zhang Hongchen
    Xu Enjiang
    ENERGY ENGINEERING AND ENVIRONMENTAL ENGINEERING, PTS 1AND 2, 2013, 316-317 : 80 - +
  • [45] A Water-to-Water Heat Pump Model with Experimental Validation
    Viviescas, Geoffrey
    Bernier, Michel
    ENERGIES, 2024, 17 (08)
  • [46] Experimental Research on a Heat Pump Water Heater Using Low Pressure Steam as Heat Source
    Fan, Jun
    Sun, Fengzhong
    Gao, Ming
    ENERGY AND POWER TECHNOLOGY, PTS 1 AND 2, 2013, 805-806 : 637 - 644
  • [47] Experimental investigation on air-source transcritical CO2 heat pump water heater system at a fixed water inlet temperature
    Wang, Shouguo
    Tuo, Hanfei
    Cao, Feng
    Xing, Ziwen
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2013, 36 (03): : 701 - 716
  • [48] Application of mine water for water-source heat pump system
    Du, Hongpu
    Dou, Yuanming
    Qi, Chengying
    ADVANCES IN ENERGY SCIENCE AND TECHNOLOGY, PTS 1-4, 2013, 291-294 : 1701 - +
  • [49] Optimal supply water temperature control of water source heat pump
    Palahanska-Mavrov, M.
    Wang, G.
    Liu, M.
    Solar Engineering 2005, 2006, : 317 - 323
  • [50] Simulation on Temperature Variation of Underground Water in Water Source Heat Pump
    Huang Tao
    Yuan Dongli
    2012 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2012,