Evaluation of Long-term Anatomic Changes Following Canaloplasty With Anterior Segment Spectral-domain Optical Coherence Tomography and Ultrasound Biomicroscopy

被引:13
|
作者
Kuerten, David [1 ]
Plange, Niklas [1 ]
Becker, Jakob [1 ]
Walter, Peter [1 ]
Fuest, Matthias [1 ]
机构
[1] Rhein Westfal TH Aachen, Dept Ophthalmol, Pauwelsstr 30, D-52074 Aachen, Germany
关键词
glaucoma; canaloplasty; intraocular pressure; bleb; OPEN-ANGLE GLAUCOMA; CIRCUMFERENTIAL VISCODILATION; FLEXIBLE MICROCATHETER; CATARACT-SURGERY; TRABECULECTOMY; ADULTS;
D O I
10.1097/IJG.0000000000000827
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background:To analyze long-term structural changes in conjunctiva, sclera and Schlemm canal (SC) with anterior segment optical coherence tomography (AS-OCT) and ultrasound biomicroscopy (UBM) following uncomplicated canaloplasty.Materials and Methods:Fifteen patients with planned canaloplasty and no intraoperative complications were included in this prospective study. AS-OCT images were acquired at 1, 3, 6 months and at a long-term time point (204.9mo) postsurgery. UBM images were acquired at 3, 6 months and long-term after canaloplasty. The surgical site was evaluated for the presence of SC, transscleral filtration, a scleral lake, and the visibility of intra-Schlemm sutures. The SC's height and width were measured at the 3 and 9 o'clock limbus position.Results:Following canaloplasty, the intraocular pressure was successfully reduced from 23.43 +/- 5.52 to 12.6 +/- 1.78mmHg (P<0.0001) at the final control visit. Topical medication was reduced from 2.9 +/- 1.1 to 0.4 +/- 0.6 over the same period. SC's increase in height was higher than that in width at the last visit (height: +351%, P=0.0004, width: +144%, P=0.002). With the UBM the SC was easily identifiable by the reflection of the tractions sutures in 75% of the patients at the last visit. Transscleral filtration was detectable in 42% of the patients at the last visit using AS-OCT and a scleral lake was still detectable by OCT in 25% of the patients and even in 42% of the patients by UBM.Conclusions:Persisting anatomic changes of SC, a transscleral filtration and a scleral lake can be recorded by AS-OCT and UBM long-term after successful canaloplasty.
引用
收藏
页码:87 / 93
页数:7
相关论文
共 50 条
  • [21] The use of anterior segment spectral domain Optical Coherence Tomography in evaluation of patients with anterior scleritis
    Levison, Ashleigh
    Lowder, Careen Y.
    Baynes, Kimberly
    Srivastava, Sunil K.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [22] Assessment of Anterior Segment Tumors with Ultrasound Biomicroscopy versus Anterior Segment Optical Coherence Tomography in 200 Cases
    Bianciotto, Carlos
    Shields, Carol L.
    Guzman, Juan M.
    Romanelli-Gobbi, Massi
    Mazzuca, Douglas, Jr.
    Green, W. Ross
    Shields, Jerry A.
    OPHTHALMOLOGY, 2011, 118 (07) : 1297 - 1302
  • [23] Imaging implanted keratoprostheses with anterior-segment optical coherence tomography and ultrasound biomicroscopy
    Garcia, Julian P. S., Jr.
    de la Cruz, Jose
    Rosen, Richard B.
    Buxton, Douglas E.
    CORNEA, 2008, 27 (02) : 180 - 188
  • [24] Correlation of anterior segment optical coherence tomography and ultrasound biomicroscopy in congenital corneal opacity
    Yangzes, Sonam
    Kaushik, Sushmita
    Malhotra, Chintan
    Thakur, Anchal
    Gupta, Amit
    Jain, Arun Kumar
    Jinagal, Jitender
    Pandav, Surinder Singh
    JOURNAL OF AAPOS, 2024, 28 (02):
  • [25] ANTERIOR SEGMENT SPECTRAL-DOMAIN OPTICAL COHERENCE TOMOGRAPHY (OCT) ANALYSIS OF BLEB MORPHOLOGY FOLLOWING DEEP SCLERECTOMY VERSES TRABECULECTOMY
    Lam, J.
    Clement, Colin I.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2013, 41 : 12 - 12
  • [26] Evaluation of spectrometric parameters in spectral-domain optical coherence tomography
    Xi, Peng
    Mei, Kai
    Braeuler, Tobias
    Zhou, Chuanqing
    Ren, Qiushi
    APPLIED OPTICS, 2011, 50 (03) : 366 - 372
  • [27] Comparison of measurements of anterior chamber angle via anterior segment optical coherence tomography and ultrasound biomicroscopy
    Yu, Zi-Yan
    Huang, Ting
    Lu, Lu
    Qu, Bo
    WORLD JOURNAL OF CLINICAL CASES, 2020, 8 (15) : 3249 - U143
  • [28] Comparison of anterior segment optical coherence tomography (OCT) and ultrasound biomicroscopy (UBM) in diagnosis of anterior scleritis
    Purgert, Robert
    Bessette, Angela
    Pichi, Francesco
    Lowder, Careen
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [29] Assessment of Anterior Chamber by Ultrasound Biomicroscopy and Anterior Segment Optical Coherence Tomography in Patients with Inflammatory Glaucoma
    Qian, Yiyong
    Liu, Lin
    Shi, Yuehui
    Wang, Minli
    Li, Min
    Zou, Jun
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2019, 47 (12) : 5950 - 5956
  • [30] Comparison of measurements of anterior chamber angle via anterior segment optical coherence tomography and ultrasound biomicroscopy
    Zi-Yan Yu
    Ting Huang
    Lu Lu
    Bo Qu
    World Journal of Clinical Cases, 2020, (15) : 3249 - 3258