Determination of air-kerma strength for the 192Ir GammaMedplus iX pulsed-dose-rate brachytherapy source

被引:3
|
作者
Riley, A. D. [1 ]
Pike, T. L. [1 ]
Micka, J. A. [1 ]
Fulkerson, R. K. [1 ]
DeWerd, L. A. [1 ]
机构
[1] Univ Wisconsin, Dept Med Phys, Madison, WI 53705 USA
关键词
Pulsed-dose-rate brachytherapy; well chamber; calibration; DOSIMETRY PARAMETERS; AAPM; CALIBRATION;
D O I
10.1118/1.4812420
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Pulsed-dose-rate (PDR) brachytherapy was originally proposed to combine the therapeutic advantages of high-dose-rate (HDR) and low-dose-rate brachytherapy. Though uncommon in the United States, several facilities employ pulsed-dose-rate brachytherapy in Europe and Canada. Currently, there is no air-kerma strength standard for PDR brachytherapy Ir-192 sources traceable to the National Institute of Standards and Technology. Discrepancies in clinical measurements of the air-kerma strength of the PDR brachytherapy sources using HDR source-calibrated well chambers warrant further investigation. Methods: In this research, the air-kerma strength for an Ir-192 PDR brachytherapy source was compared with the University of Wisconsin Accredited Dosimetry Calibration Laboratory transfer standard well chambers, the seven-distance technique [B. E. Rasmussen et al., "The air-kerma strength standard for Ir-192 HDR sources," Med. Phys. 38, 6721-6729 (2011)], and the manufacturer's stated value. Radiochromic film and Monte Carlo techniques were also employed for comparison to the results of the measurements. Results: While the measurements using the seven-distance technique were within + 0.44% from the manufacturer's determination, there was a + 3.10% difference between the transfer standard well chamber measurements and the manufacturer's stated value. Results showed that the PDR brachytherapy source has geometric and thus radiological qualities that exhibit behaviors similar to a point source model in contrast to a conventional line source model. Conclusions: The resulting effect of the pointlike characteristics of the PDR brachytherapy source likely account for the differences observed between well chamber and in-air measurements. (C) 2013 American Association of Physicists in Medicine.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] High-Dose-Rate 192Ir Brachytherapy Dose Verification: A Phantom Study
    Nikoofar, Alireza
    Hoseinpour, Zohreh
    Mahdavi, Seied Rabi
    Hasanzadeh, Hadi
    Tavirani, Mostafa Rezaei
    IRANIAN JOURNAL OF CANCER PREVENTION, 2015, 8 (03)
  • [42] An EGSnrc investigation of the air-kerma strength, dose rate constant, and radial dose function of 125I brachytherapy sources
    Sahoo S.
    Palani Selvam T.
    Radiological Physics and Technology, 2009, 2 (2) : 198 - 204
  • [43] Comparison BIPM.RI(I)-K8 of high dose rate 192Ir brachytherapy standards for reference air kerma rate of the NFL and the BIPM
    Alvarez, J. T.
    Sander, T.
    de Pooter, J. A.
    Allisy-Roberts, P. J.
    Kessler, C.
    METROLOGIA, 2014, 51
  • [44] Air-Kerma Strength and Dose Rate Constant by the Full Monte Carlo Simulations
    Tsuji, S.
    Oita, M.
    Narihiro, N.
    MEDICAL PHYSICS, 2016, 43 (06) : 3469 - 3469
  • [45] Air-kerma strength determination of a new directional 103Pd source
    Aima, Manik
    Reed, Joshua L.
    DeWerd, Larry A.
    Culberson, Wesley S.
    MEDICAL PHYSICS, 2015, 42 (12) : 7144 - 7152
  • [46] Dosimetric investigation of a new high dose rate 192Ir brachytherapy source, IRAsource, by Monte Carlo method
    Rostami, Atefeh
    Hoseini, Mahdi
    Ghorbani, Mahdi
    Knaup, Courtney
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2020, 25 (01) : 139 - 145
  • [47] Comparison BIPM.RI(I)-K8 of high dose-rate 192Ir brachytherapy standards for reference air kerma rate of the PTB and the BIPM
    Kessler, C.
    Behrens, R.
    Kasper, A.
    Grote, F.
    Metrologia, 2024, 61 (1 A)
  • [48] EVALUATION OF SCATTER CONTRIBUTION AND DISTANCE ERROR BY ITERATIVE METHODS FOR STRENGTH DETERMINATION OF HDR 192IR BRACHYTHERAPY SOURCE
    Kumar, Sudhir
    Srinivasan, Panchapakesan
    Sharma, Sunil D.
    Subbaiah, Kamatam V.
    Mayya, Yelia S.
    MEDICAL DOSIMETRY, 2010, 35 (03) : 230 - 237
  • [49] First experience of 192Ir source stuck event during high-dose-rate brachytherapy in Japan
    Kumagai, Shinobu
    Arai, Norikazu
    Takata, Takeshi
    Kon, Daisuke
    Saitoh, Toshiya
    Oba, Hiroshi
    Furui, Shigeru
    Kotoku, Jun'ichi
    Shiraishi, Kenshiro
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2020, 12 (01) : 53 - 60
  • [50] Monte Carlo angular dose distribution of the microselectron HDR 192Ir brachytherapy source
    Wallace, S.
    Wong, T.
    Fernando, W.
    Australasian Physical and Engineering Sciences in Medicine, 1999, 22 (01): : 1 - 7