Determination of air-kerma strength for the 192Ir GammaMedplus iX pulsed-dose-rate brachytherapy source

被引:3
|
作者
Riley, A. D. [1 ]
Pike, T. L. [1 ]
Micka, J. A. [1 ]
Fulkerson, R. K. [1 ]
DeWerd, L. A. [1 ]
机构
[1] Univ Wisconsin, Dept Med Phys, Madison, WI 53705 USA
关键词
Pulsed-dose-rate brachytherapy; well chamber; calibration; DOSIMETRY PARAMETERS; AAPM; CALIBRATION;
D O I
10.1118/1.4812420
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Pulsed-dose-rate (PDR) brachytherapy was originally proposed to combine the therapeutic advantages of high-dose-rate (HDR) and low-dose-rate brachytherapy. Though uncommon in the United States, several facilities employ pulsed-dose-rate brachytherapy in Europe and Canada. Currently, there is no air-kerma strength standard for PDR brachytherapy Ir-192 sources traceable to the National Institute of Standards and Technology. Discrepancies in clinical measurements of the air-kerma strength of the PDR brachytherapy sources using HDR source-calibrated well chambers warrant further investigation. Methods: In this research, the air-kerma strength for an Ir-192 PDR brachytherapy source was compared with the University of Wisconsin Accredited Dosimetry Calibration Laboratory transfer standard well chambers, the seven-distance technique [B. E. Rasmussen et al., "The air-kerma strength standard for Ir-192 HDR sources," Med. Phys. 38, 6721-6729 (2011)], and the manufacturer's stated value. Radiochromic film and Monte Carlo techniques were also employed for comparison to the results of the measurements. Results: While the measurements using the seven-distance technique were within + 0.44% from the manufacturer's determination, there was a + 3.10% difference between the transfer standard well chamber measurements and the manufacturer's stated value. Results showed that the PDR brachytherapy source has geometric and thus radiological qualities that exhibit behaviors similar to a point source model in contrast to a conventional line source model. Conclusions: The resulting effect of the pointlike characteristics of the PDR brachytherapy source likely account for the differences observed between well chamber and in-air measurements. (C) 2013 American Association of Physicists in Medicine.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] Erratum to: Monte Carlo dosimetry of the IRAsource high dose rate 192Ir brachytherapy source
    Akbar Sarabiasl
    Navid Ayoobian
    Hossein Poorbaygi
    Iraj Jabbari
    Mohammad Reza Javanshir
    Australasian Physical & Engineering Sciences in Medicine, 2016, 39 : 591 - 591
  • [32] Design of a phantom for the quality control of high dose rate 192Ir source used in brachytherapy
    Ochoa, Ricardo
    Gomez, Fredy
    Ferreira, Ivaldo H.
    Gutt, Federico
    de Almeida, Carlos E.
    RADIOTHERAPY AND ONCOLOGY, 2007, 82 (02) : 222 - 228
  • [33] Monte Carlo and TLD dosimetry of an 192Ir high dose-rate brachytherapy source
    Karaiskos, P
    Angelopoulos, A
    Sakelliou, L
    Sandilos, P
    Antypas, C
    Vlachos, L
    Koutsouveli, E
    MEDICAL PHYSICS, 1998, 25 (10) : 1975 - 1984
  • [34] Dosimetry Parameters of the IRH10 192Ir High Dose Rate Brachytherapy Source
    Yi, Chul-Young
    Chun, Kook Jin
    Hah, Suck-Ho
    Kim, Hyun-Moon
    Lim, Chunil
    JOURNAL OF RADIATION RESEARCH, 2010, 51 (04) : 485 - 492
  • [35] High dose rate 192Ir afterloading brachytherapy for cancer of the vagina
    Kushner, DM
    Fleming, PA
    Kennedy, AW
    Wilkinson, DA
    Lee, E
    Saffle, PA
    BRITISH JOURNAL OF RADIOLOGY, 2003, 76 (910): : 719 - 725
  • [36] Quality control of 192Ir High Dose Rate Brachytherapy sources
    Pereira, A
    Pirraco, R
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S136 - S137
  • [37] Determination of transit dose profile for a 192Ir HDR source
    Fonseca, G. P.
    Rubo, R. A.
    Minamisawa, R. A.
    dos Santos, G. R.
    Antunes, P. C. G.
    Yoriyaz, H.
    MEDICAL PHYSICS, 2013, 40 (05)
  • [38] Reference air kerma rate calibration system for high dose rate Ir-192 brachytherapy sources in Taiwan
    Chu, Wei-Han
    Yuan, Ming-Chen
    Lee, Jeng-Hung
    Lin, Yi-Chun
    RADIATION PHYSICS AND CHEMISTRY, 2017, 140 : 361 - 364
  • [39] A Monte Carlo investigation of the dosimetric characteristics of the VariSource 192Ir high dose rate brachytherapy source
    Karaiskos, P
    Angelopoulos, A
    Baras, P
    Sakelliou, L
    Sandilos, P
    Dardoufas, K
    Vlachos, L
    MEDICAL PHYSICS, 1999, 26 (08) : 1498 - 1502
  • [40] A system for localization of high dose rate 192Ir source during brachytherapy treatment with silicon detectors
    Batic, Matej
    Burger, Janez
    Cindro, Vladimir
    Kramberger, Gregor
    Mandic, Igor
    Mikuz, Marko
    Studen, Andrej
    Zavrtanik, Marko
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3794 - +