Reduction of signal suppression effects in ESI-MS using a nanosplitting device

被引:145
|
作者
Gangl, ET
Annan, M
Spooner, N
Vouros, P [1 ]
机构
[1] Northeastern Univ, Barnett Inst, Boston, MA 02115 USA
[2] Northeastern Univ, Dept Chem, Boston, MA 02115 USA
[3] GlaxoSmithKline Pharmaceut, King Of Prussia, PA 19406 USA
关键词
D O I
10.1021/ac010501i
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Electrospray ionization mass spectrometry is a valuable tool in the identification and quantification of drug metabolites in biological fluids. However, there are many instances where matrix components present in these fluids interfere with analyte detection and prevent the acquisition of accurate or complete results. In some instances, the matrix can suppress ionization to such an extent that analytes are completely undetectable by MS. In this work, we investigate how ionization and ion-transfer efficiencies are affected by drastically reducing the flow into the MS. A postcolumn concentric flow-splitting device was constructed to allow the measurement of analyte signal and ionization suppression across a range of flow rates (0.1-200 muL/min). Using this device, the effects of flow rate on signal intensity and ionization suppression were measured in analytical experiments that included flow injection analysis MS, postcolumn addition LC-MS, and on-line LC-MS analysis of metabolites generated from rat liver microsomes. The device used to deliver 0.1 muL/min flows is referred to as a nanosplitter because it achieved high split ratios (2000: 1), producing flow rates comparable to those observed in nanoelectrospray. The nanosplitter maintained chromatographic integrity with high fidelity and allowed the direct comparison of analyte signal across a range of flow rates (0.1-200 muL/min). A significant improvement in concentration and mass sensitivity as well as a reduction in signal suppression is observed when the performance at 200 versus 0.1 muL/min flow rate is compared. Using this specially designed concentric splitting device, the advantages of ultralow flow ESI were easily exploited for applications employing large bore chromatography.
引用
收藏
页码:5635 / 5644
页数:10
相关论文
共 50 条
  • [41] Development of a precise quantitative method for monitoring sirolimus in whole blood using LC/ESI-MS/MS
    Shigeta, Kensuke
    Kikuchi, Masafumi
    Tanaka, Masaki
    Takasaki, Shinya
    Oishi, Hisashi
    Sado, Tetsu
    Matsuda, Yasushi
    Noda, Masafumi
    Okada, Yoshinori
    Mano, Nariyasu
    Yamaguchi, Hiroaki
    BIOMEDICAL CHROMATOGRAPHY, 2020, 34 (08)
  • [42] Sample optimization for rapid identification of nucleosides and bases from ascidian extracts using ESI-MS/MS
    Takeara, Renata
    Jimenez, Paula C.
    Costa-Lotufo, Leticia V.
    Lopes, Joao L. C.
    Lopes, Norberto P.
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2007, 18 (05) : 1054 - 1060
  • [43] Detection of peptides with intact phosphate groups using MALDI TOF/TOF and comparison with the ESI-MS/MS
    Jagannadham, Medicharla, V
    Kameshwari, D. B.
    Gayathri, P.
    Nagaraj, R.
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2018, 24 (02) : 231 - 242
  • [44] Analysis of gold nanoparticles using ICP-MS-based hyphenated and complementary ESI-MS techniques
    Helfrich, Andreas
    Bettmer, Joerg
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2011, 307 (1-3) : 92 - 98
  • [45] Optimization Based on ANSYS Electric Numerical Method for a Novel MEMS ESI-MS Ion Focusing Device
    Yue, Cuihong
    Zou, Helin
    MEMS/NEMS NANO TECHNOLOGY, 2011, 483 : 727 - 730
  • [46] Effects of Amino Acid Additives on Protein Stability during Electrothermal Supercharging in ESI-MS
    Javanshad, Roshan
    Panth, Rajendra
    Venter, Andre R.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2023, 35 (01) : 151 - 157
  • [47] Molecular Speciation of Isopolyoxomolybdates and Isopolyoxotungstates with Silicic Acid in Aqueous Solution Using ESI-MS
    Osuka, Yuri
    Ii, Kyota
    Tsuchiya, Kotaro
    Nemoto, Masao
    Sahoo, Yu Vin
    Takahashi, Kazuya
    Tanaka, Miho
    JOURNAL OF SOLUTION CHEMISTRY, 2024, 53 (05) : 642 - 654
  • [48] Edible oil fingerprinting using direct infusion ESI-MS and principal component analysis
    McNamara, Marisa
    Loukotkova, Lucie
    da Costa, Goncalo Gamboa
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2017, 253
  • [49] Characterization of the conformational changes in recombinant human metallothioneins using ESI-MS and molecular modeling
    Chan, Jayna
    Huang, Zuyun
    Watt, Ian
    Kille, Peter
    Stillman, Martin J.
    CANADIAN JOURNAL OF CHEMISTRY, 2007, 85 (10) : 898 - 912
  • [50] Online Coupling System and Control Software for Reaction Monitoring using Microreactors and ESI-MS
    Fleischer, Heidi
    Hoffmann, Dany
    Almahaini, Nwar
    Vinh Quang Do
    Thurow, Kerstin
    2015 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2015, : 1561 - 1566