Reduction of signal suppression effects in ESI-MS using a nanosplitting device

被引:145
|
作者
Gangl, ET
Annan, M
Spooner, N
Vouros, P [1 ]
机构
[1] Northeastern Univ, Barnett Inst, Boston, MA 02115 USA
[2] Northeastern Univ, Dept Chem, Boston, MA 02115 USA
[3] GlaxoSmithKline Pharmaceut, King Of Prussia, PA 19406 USA
关键词
D O I
10.1021/ac010501i
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Electrospray ionization mass spectrometry is a valuable tool in the identification and quantification of drug metabolites in biological fluids. However, there are many instances where matrix components present in these fluids interfere with analyte detection and prevent the acquisition of accurate or complete results. In some instances, the matrix can suppress ionization to such an extent that analytes are completely undetectable by MS. In this work, we investigate how ionization and ion-transfer efficiencies are affected by drastically reducing the flow into the MS. A postcolumn concentric flow-splitting device was constructed to allow the measurement of analyte signal and ionization suppression across a range of flow rates (0.1-200 muL/min). Using this device, the effects of flow rate on signal intensity and ionization suppression were measured in analytical experiments that included flow injection analysis MS, postcolumn addition LC-MS, and on-line LC-MS analysis of metabolites generated from rat liver microsomes. The device used to deliver 0.1 muL/min flows is referred to as a nanosplitter because it achieved high split ratios (2000: 1), producing flow rates comparable to those observed in nanoelectrospray. The nanosplitter maintained chromatographic integrity with high fidelity and allowed the direct comparison of analyte signal across a range of flow rates (0.1-200 muL/min). A significant improvement in concentration and mass sensitivity as well as a reduction in signal suppression is observed when the performance at 200 versus 0.1 muL/min flow rate is compared. Using this specially designed concentric splitting device, the advantages of ultralow flow ESI were easily exploited for applications employing large bore chromatography.
引用
收藏
页码:5635 / 5644
页数:10
相关论文
共 50 条
  • [11] Analysis of Clarithromycin and Its Impurities KL and KO Using ESI-MS/MS
    Jiang K.-Z.
    Jin Y.
    Wang Z.-G.
    Fu J.-P.
    Qin X.-R.
    Hou Z.-K.
    Pan Y.-J.
    Journal of Chinese Mass Spectrometry Society, 2021, 42 (01) : 8 - 15
  • [12] The analysis of antimony species by using ESI-MS and HPLC-ICP-MS
    Lintschinger, J
    Schramel, O
    Kettrup, A
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 361 (02): : 96 - 102
  • [13] The analysis of antimony species by using ESI-MS and HPLC-ICP-MS
    J. Lintschinger
    O. Schramel
    A. Kettrup
    Fresenius' Journal of Analytical Chemistry, 1998, 361 : 96 - 102
  • [14] Determination of multipeptide mixture by using CZE coupled with ESI-MS
    Liang, Z
    Zhang, WB
    Zhang, YK
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2004, 25 (03): : 448 - 450
  • [15] Identification and elimination of ion suppression in the quantitative analysis of sirolimus in human blood by LC/ESI-MS/MS
    Mano, Nariyasu
    Nozawa, Marina
    Sato, Mayumi
    Mori, Masaru
    Yamaguchi, Hiroaki
    Kanda, Katsuhiro
    Nogami, Makoto
    Goto, Junichi
    Shimada, Miki
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (13-14): : 968 - 974
  • [16] MS/MS study of deoxydinucleotides bound with alkali-metal ions using ESI-MS
    Abliz, Z
    Takayama, M
    Xiang, Y
    Li, JL
    CHINESE CHEMICAL LETTERS, 2003, 14 (05) : 499 - 502
  • [17] MS/MS Study of Deoxydinucleotides Bound with Alkali-metal Ions Using ESI-MS
    Zeper ABLIZ1*
    Chinese Chemical Letters, 2003, (05) : 499 - 502
  • [18] Capillary-LC-μESI-MS/MS and nano-LC-nano ESI-MS/MS analysis using a single binary pump capillary LC system:: Applications in proteomics
    Song, L
    Choi, KS
    Park, YM
    Kazim, AL
    Marlar, K
    Kong, ES
    Park, EM
    Kim, YH
    Koo, KH
    Chae, HZ
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2005, 28 (09) : 1271 - 1289
  • [19] Isolation and characterization of process related impurities of olanzapine using HPLC and ESI-MS/MS
    Rao, Ramisetti Nageswara
    Raju, Ale Narasa
    Narsimha, Ramaram
    Babu, Ganduri Raveendra
    JOURNAL OF SEPARATION SCIENCE, 2008, 31 (01) : 107 - 118
  • [20] Characterization of plasma acylcarnitines in patients under valproate monotherapy using ESI-MS/MS
    Silva, MFB
    Selhorst, J
    Overmars, H
    van Gennip, AH
    Maya, M
    Wanders, RJA
    de Almeida, IT
    Duran, M
    CLINICAL BIOCHEMISTRY, 2001, 34 (08) : 635 - 638