Reduction of signal suppression effects in ESI-MS using a nanosplitting device

被引:145
|
作者
Gangl, ET
Annan, M
Spooner, N
Vouros, P [1 ]
机构
[1] Northeastern Univ, Barnett Inst, Boston, MA 02115 USA
[2] Northeastern Univ, Dept Chem, Boston, MA 02115 USA
[3] GlaxoSmithKline Pharmaceut, King Of Prussia, PA 19406 USA
关键词
D O I
10.1021/ac010501i
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Electrospray ionization mass spectrometry is a valuable tool in the identification and quantification of drug metabolites in biological fluids. However, there are many instances where matrix components present in these fluids interfere with analyte detection and prevent the acquisition of accurate or complete results. In some instances, the matrix can suppress ionization to such an extent that analytes are completely undetectable by MS. In this work, we investigate how ionization and ion-transfer efficiencies are affected by drastically reducing the flow into the MS. A postcolumn concentric flow-splitting device was constructed to allow the measurement of analyte signal and ionization suppression across a range of flow rates (0.1-200 muL/min). Using this device, the effects of flow rate on signal intensity and ionization suppression were measured in analytical experiments that included flow injection analysis MS, postcolumn addition LC-MS, and on-line LC-MS analysis of metabolites generated from rat liver microsomes. The device used to deliver 0.1 muL/min flows is referred to as a nanosplitter because it achieved high split ratios (2000: 1), producing flow rates comparable to those observed in nanoelectrospray. The nanosplitter maintained chromatographic integrity with high fidelity and allowed the direct comparison of analyte signal across a range of flow rates (0.1-200 muL/min). A significant improvement in concentration and mass sensitivity as well as a reduction in signal suppression is observed when the performance at 200 versus 0.1 muL/min flow rate is compared. Using this specially designed concentric splitting device, the advantages of ultralow flow ESI were easily exploited for applications employing large bore chromatography.
引用
收藏
页码:5635 / 5644
页数:10
相关论文
共 50 条
  • [1] Major signal suppression from metal ion clusters in SFC/ESI-MS - Cause and effects
    Haglind, Alfred
    Hedeland, Mikael
    Arvidsson, Torbjorn
    Pettersson, Curt E.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2018, 1084 : 96 - 105
  • [2] Effects of valproate on acylcarnitines in children with epilepsy using ESI-MS/MS
    Werner, Tamara
    Treiss, Irmgard
    Kohlmueller, Dirk
    Mehlem, Peter
    Teich, Martin
    Longin, Elke
    Gerstner, Thorsten
    Koenig, Stephan A.
    Schulze, Andreas
    EPILEPSIA, 2007, 48 (01) : 72 - 76
  • [3] Strategies for avoiding saturation effects in ESI-MS
    Wei, Alan An Jung
    Joshi, Anuj
    Chen, Yuxuan
    McIndoe, J. Scott
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2020, 450
  • [4] A mechanistic investigation of hydrodehalogenation using ESI-MS
    Ahmadi, Zohrab
    McIndoe, J. Scott
    CHEMICAL COMMUNICATIONS, 2013, 49 (98) : 11488 - 11490
  • [5] LC/ESI-MS analysis of proteins using
    Banks, J.F.
    Quinn, J.P.
    Whitehouse, C.M.
    Analytical Chemistry, 1994, 66 (21)
  • [6] Decoding the signal response of steroids in electrospray ionization mode (ESI-MS)
    Alymatiri, Christina M.
    Kouskoura, Maria G.
    Markopoulou, Catherine K.
    ANALYTICAL METHODS, 2015, 7 (24) : 10433 - 10444
  • [7] Quantification of intact covalentlymetal labeled proteins using ESI-MS/MS
    Benda, David
    Schwarz, Gunnar
    Beck, Sebastian
    Linscheid, Michael W.
    JOURNAL OF MASS SPECTROMETRY, 2014, 49 (01): : 13 - 18
  • [8] Chlorinated vs. chloraminated drinking water: Toxicity-based identification of disinfection by-products using ESI-MS and ESI-MS/MS
    Richardson, Susan D.
    Crumley, F. Gene
    Plewa, Michael J.
    Wagner, Elizabeth D.
    Mize, Todd
    Ange, Peggi
    Orlando, Ron
    Williamson, Leah
    Bartlett, Michael G.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2007, 233 : 572 - 572
  • [9] Structure, Anion, and Solvent Effects on Cation Response in ESI-MS
    Omari, Isaac
    Randhawa, Parmissa
    Randhawa, Jaiya
    Yu, Jenny
    McIndoe, J. Scott
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2019, 30 (09) : 1750 - 1757
  • [10] Degradation study of stevioside using RP-HPLC and ESI-MS/MS
    Martono, Yohanes
    Rohman, Abdul
    Martono, Sudibyo
    Riyanto, Sugeng
    MALAYSIAN JOURNAL OF FUNDAMENTAL AND APPLIED SCIENCES, 2018, 14 : 138 - 141