Method for Cleaning Back-Produced Water from Polymer Flooding Operations to Determine Polymer Molar Mass Using Size-Exclusion Chromatography

被引:3
|
作者
Carvalho, Suzanny P. [1 ]
Dip, M. M. [1 ]
Lucas, Elizabete F. [1 ,2 ]
机构
[1] Univ Fed Rio de Janeiro UFRJ, Lab Adit Polimer Prod Petr, Inst Alberto Luiz Coimbra Posgrad & Pesquisa Engn, Programa Posgrad Engn Met & Mat COPPE PEMM, BR-21941594 Rio De Janeiro, RJ, Brazil
[2] Univ Fed Rio de Janeiro UFRJ, Inst Macromol, Lab Macromol & Coloides Ind Petr, BR-21941598 Rio De Janeiro, RJ, Brazil
关键词
polymer flooding; polyacrylamide degradation; methodology for water treatment; size-exclusion chromatography; ENHANCED OIL-RECOVERY; FIELD; POLYACRYLAMIDE;
D O I
10.21577/0103-5053.20200138
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
One of the methods used by the oil industry to increase production is to inject water, containing polymer, into the reservoir. The viscosity of the aqueous solution is primarily responsible for the efficiency of this method, and is achieved using polymers with high molar mass. However, polymer degradation can occur during pumping and fluid displacement in the porous medium, reducing the efficiency of the polymer flooding method. Therefore, it is important to monitor the molar mass of the polymer in the produced water. Size-exclusion chromatography (SEC) is a powerful method for determining average molar mass of polymers, but the impurities present in the produced water, such as salts and residual oil, can significantly affect the analysis. There is no method described in the literature for pretreating produced water before injecting it into the chromatograph. Therefore, the purpose of this work was to develop a reliable method for this pretreatment, without affecting the molar mass of the polymer. The results showed that an efficient method, which does not cause polymer degradation, must contain four steps: (i) heating, (ii) regular filtration, (iii) elution in poly(divinylbenzene) resin, and (iv) dialysis.
引用
收藏
页码:2583 / 2589
页数:7