Method for Cleaning Back-Produced Water from Polymer Flooding Operations to Determine Polymer Molar Mass Using Size-Exclusion Chromatography

被引:3
|
作者
Carvalho, Suzanny P. [1 ]
Dip, M. M. [1 ]
Lucas, Elizabete F. [1 ,2 ]
机构
[1] Univ Fed Rio de Janeiro UFRJ, Lab Adit Polimer Prod Petr, Inst Alberto Luiz Coimbra Posgrad & Pesquisa Engn, Programa Posgrad Engn Met & Mat COPPE PEMM, BR-21941594 Rio De Janeiro, RJ, Brazil
[2] Univ Fed Rio de Janeiro UFRJ, Inst Macromol, Lab Macromol & Coloides Ind Petr, BR-21941598 Rio De Janeiro, RJ, Brazil
关键词
polymer flooding; polyacrylamide degradation; methodology for water treatment; size-exclusion chromatography; ENHANCED OIL-RECOVERY; FIELD; POLYACRYLAMIDE;
D O I
10.21577/0103-5053.20200138
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
One of the methods used by the oil industry to increase production is to inject water, containing polymer, into the reservoir. The viscosity of the aqueous solution is primarily responsible for the efficiency of this method, and is achieved using polymers with high molar mass. However, polymer degradation can occur during pumping and fluid displacement in the porous medium, reducing the efficiency of the polymer flooding method. Therefore, it is important to monitor the molar mass of the polymer in the produced water. Size-exclusion chromatography (SEC) is a powerful method for determining average molar mass of polymers, but the impurities present in the produced water, such as salts and residual oil, can significantly affect the analysis. There is no method described in the literature for pretreating produced water before injecting it into the chromatograph. Therefore, the purpose of this work was to develop a reliable method for this pretreatment, without affecting the molar mass of the polymer. The results showed that an efficient method, which does not cause polymer degradation, must contain four steps: (i) heating, (ii) regular filtration, (iii) elution in poly(divinylbenzene) resin, and (iv) dialysis.
引用
收藏
页码:2583 / 2589
页数:7
相关论文
共 47 条
  • [21] Estimation of band broadening in size-exclusion chromatography. I. A method based on analyzing narrow standards with a molar mass-sensitive detector
    Yossen, Mariana M.
    Vega, Jorge R.
    Meira, Gregorio R.
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1128 (1-2) : 171 - 180
  • [22] Comparison of Molar Mass Determination of Poly(dimethylsiloxanes) by Size Exclusion Chromatography and High-Resolution Polymer High Performance Liquid Chromatography Based on a Sawtooth Gradient
    Durner, Bernhard
    Scherer, Beate
    Ehmann, Thomas
    Matysik, Frank-Michael
    ACS APPLIED POLYMER MATERIALS, 2019, 1 (09): : 2388 - 2397
  • [23] Improvements in polymer characterization by size-exclusion chromatography and liquid chromatography at the critical condition by using enhanced-fluidity liquid mobile phases with packed capillary columns
    Yun, H
    Olesik, SV
    Marti, EH
    ANALYTICAL CHEMISTRY, 1998, 70 (15) : 3298 - 3303
  • [24] Determination of modifier contents in polymer-modified bitumens and in samples collected from the roads using high-performance gel permeation/size-exclusion chromatography
    Kosinska, Judyta
    Boczkaj, Grzegorz
    Galezowska, Grazyna
    Podwysocka, Joanna
    Przyjazny, Andrzej
    Kaminski, Marian
    ROAD MATERIALS AND PAVEMENT DESIGN, 2016, 17 (03) : 547 - 562
  • [25] Statistical Modelling of Oil Removal from Surfactant/Polymer Flooding Produced Water by Using Flotation Column
    Hani, Ku Esyra
    Ayoub, Mohammed Abdalla
    INDONESIAN JOURNAL OF CHEMISTRY, 2020, 20 (02) : 360 - 367
  • [26] Validation of a high-performance size-exclusion chromatography method to determine and characterize β-glucans in beer wort using a triple-detector array
    Tomasi, Ivan
    Marconi, Ombretta
    Sileoni, Valeria
    Perretti, Giuseppe
    FOOD CHEMISTRY, 2017, 214 : 176 - 182
  • [27] A Non-Centrifugation Method to Concentrate and Purify Extracellular Vesicles Using Superabsorbent Polymer Followed by Size Exclusion Chromatography
    Bergqvist, Markus
    Lasser, Cecilia
    Crescitelli, Rossella
    Park, Kyong-Su
    Lotvall, Jan
    JOURNAL OF EXTRACELLULAR VESICLES, 2025, 14 (01)
  • [28] Characterization of water-soluble brown carbon chromophores from wildfire plumes in the western USA using size-exclusion chromatography
    Azzarello, Lisa
    Washenfelder, Rebecca A.
    Robinson, Michael A.
    Franchin, Alessandro
    Womack, Caroline C.
    Holmes, Christopher D.
    Brown, Steven S.
    Middlebrook, Ann
    Newberger, Tim
    Sweeney, Colm
    Young, Cora J.
    ATMOSPHERIC CHEMISTRY AND PHYSICS, 2023, 23 (24) : 15643 - 15654
  • [29] Polymer characterization using packed capillary size exclusion and critical adsorption chromatography combined with MALDI-TOF mass spectrometry
    Yun, Hao
    Olesik, Susan V.
    Marti, Edward H.
    Journal of Microcolumn Separations, 11 (01): : 53 - 61
  • [30] Polymer characterization using packed capillary size exclusion and critical adsorption chromatography combined with MALDI-TOF mass spectrometry
    Yun, H
    Olesik, SV
    Marti, EH
    JOURNAL OF MICROCOLUMN SEPARATIONS, 1999, 11 (01) : 53 - 61