Lateral Resistance of Unreinforced Masonry Walls Strengthened With Engineered Cementitious Composite

被引:30
|
作者
Choi, Hyun-Ki [1 ]
Bae, Baek-Il [2 ]
Choi, Chang-Sik [3 ]
机构
[1] Kyungnam Univ, Dept Fire & Disaster Prevent Engn, Chang Won 631701, Gyeongsangnam D, South Korea
[2] Hanyang Univ, Res Inst Ind Sci, 17 Haengdang Dong, Seoul 133791, South Korea
[3] Hanyang Univ, Dept Architectural Engn, 17 Haengdang Dong, Seoul 133791, South Korea
基金
新加坡国家研究基金会;
关键词
Unreinforced masonry (URM); Wall; Sprayable engineered cementitious composite (ECC); Strength enhancement;
D O I
10.1007/s40999-016-0026-1
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Replacement of existing unreinforced masonry (URM) walls, commonly used as a non-structural member in apartments, with new reinforced concrete (RC) components has been used as a reliable method when remodeling is carried out. However, special care needs to be taken when URM walls are removed not to waste construction time and materials. Therefore, retrofitting existing URM walls can be deemed a better solution rather than replacing URM walls with RC ones. Using shotcrete is one of retrofitting techniques of URM walls. However, using normal shotcrete cannot improve adequate ductility and may cause brittle failure at a wall frame or slab connection. Therefore, new materials, such as engineered cementitious composite (ECC) and ultra-high performance concrete (UHPC) have emerged to resolve the problem of normal shotcrete by increasing ductility and toughness of retrofitting materials. In this study, sprayed ECC was used to increase both strength and ductility of existing URM walls. The results of two retrofitted URM walls under lateral quasi-static loading were compared to non-retrofitted one. One strengthened wall, retrofitted masonry wall (RTM)-ECC, was just sprayed and anchored to a wall base. Another strengthened wall, RTM-ECC-WM, was the same as RTM-ECC except for addition of wire mesh. The retrofitted specimens showed significant increase of strength, ductility, and energy dissipation capacity in comparison with the control one. In addition, RTM-ECC-WM indicated higher strength degradation due to the load transferring effect of wire mesh than RTM-ECC.
引用
收藏
页码:411 / 424
页数:14
相关论文
共 50 条
  • [31] Analytical modelling of out-of-plane flexural response of unreinforced and strengthened masonry walls
    Padalu, Pravin Kumar Venkat Rao
    Singh, Yogendra
    Das, Sreekanta
    ENGINEERING STRUCTURES, 2020, 218
  • [32] Experimental study on performance of repaired and strengthened unreinforced masonry walls using polypropylene bands
    Ebrahimzadeh, S.
    Nasrollahzadeh, K.
    SCIENTIA IRANICA, 2023, 30 (03) : 918 - 935
  • [33] Unreinforced Concrete Masonry Walls Strengthened with CFRP Sheets and Strips under Pendulum Impact
    Cheng, Lijuan
    McComb, Ashley M.
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2010, 14 (06) : 775 - 783
  • [34] Out-of-plane behavior of unreinforced masonry brick walls strengthened with CFRP strips
    Anil, Ozgur
    Tatayoglu, Muhammed
    Demirhan, Murat
    CONSTRUCTION AND BUILDING MATERIALS, 2012, 35 : 614 - 624
  • [35] Impact response and endurance of unreinforced masonry walls strengthened with cement-based composites
    Leblouba, Moussa
    Altoubat, Salah
    Karzad, A. S.
    Maalej, Mohamed
    Barakat, Samer
    Metawa, Abdulrahman
    STRUCTURES, 2022, 36 : 262 - 279
  • [36] Out-of-plane Testing of Unreinforced Masonry Walls Strengthened Using ECC Shotcrete
    Lin, Y.
    Lawley, Derek
    Wotherspoon, Liam
    Ingham, Jason M.
    STRUCTURES, 2016, 7 : 33 - 42
  • [37] Cyclic loading tests of flexural-failure dominant URM walls strengthened with engineered cementitious composite
    Deng, Mingke
    Dong, Zhifang
    Ma, Ping
    ENGINEERING STRUCTURES, 2019, 194 : 173 - 182
  • [38] Cyclic Behavior of Masonry Shear Walls Retrofitted with Engineered Cementitious Composite and Pseudoelastic Shape Memory Alloy
    Tabrizikahou, Alireza
    Kuczma, Mieczyslaw
    Lasecka-Plura, Magdalena
    Noroozinejad Farsangi, Ehsan
    SENSORS, 2022, 22 (02)
  • [39] Finite element analysis on unreinforced masonry walls with openings under lateral loads
    Hou, Y. J.
    Gu, X. L.
    Li, X.
    BRICK AND BLOCK MASONRY: TRENDS, INNOVATIONS AND CHALLENGES, 2016, : 211 - 216
  • [40] Numerical simulation of soft brick unreinforced masonry walls subjected to lateral loads
    Vemuri, Jayaprakash
    Ehteshamuddin, Syed
    Kolluru, Subramaniam
    COGENT ENGINEERING, 2018, 5 (01): : 1 - 21