Lateral Resistance of Unreinforced Masonry Walls Strengthened With Engineered Cementitious Composite

被引:30
|
作者
Choi, Hyun-Ki [1 ]
Bae, Baek-Il [2 ]
Choi, Chang-Sik [3 ]
机构
[1] Kyungnam Univ, Dept Fire & Disaster Prevent Engn, Chang Won 631701, Gyeongsangnam D, South Korea
[2] Hanyang Univ, Res Inst Ind Sci, 17 Haengdang Dong, Seoul 133791, South Korea
[3] Hanyang Univ, Dept Architectural Engn, 17 Haengdang Dong, Seoul 133791, South Korea
基金
新加坡国家研究基金会;
关键词
Unreinforced masonry (URM); Wall; Sprayable engineered cementitious composite (ECC); Strength enhancement;
D O I
10.1007/s40999-016-0026-1
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Replacement of existing unreinforced masonry (URM) walls, commonly used as a non-structural member in apartments, with new reinforced concrete (RC) components has been used as a reliable method when remodeling is carried out. However, special care needs to be taken when URM walls are removed not to waste construction time and materials. Therefore, retrofitting existing URM walls can be deemed a better solution rather than replacing URM walls with RC ones. Using shotcrete is one of retrofitting techniques of URM walls. However, using normal shotcrete cannot improve adequate ductility and may cause brittle failure at a wall frame or slab connection. Therefore, new materials, such as engineered cementitious composite (ECC) and ultra-high performance concrete (UHPC) have emerged to resolve the problem of normal shotcrete by increasing ductility and toughness of retrofitting materials. In this study, sprayed ECC was used to increase both strength and ductility of existing URM walls. The results of two retrofitted URM walls under lateral quasi-static loading were compared to non-retrofitted one. One strengthened wall, retrofitted masonry wall (RTM)-ECC, was just sprayed and anchored to a wall base. Another strengthened wall, RTM-ECC-WM, was the same as RTM-ECC except for addition of wire mesh. The retrofitted specimens showed significant increase of strength, ductility, and energy dissipation capacity in comparison with the control one. In addition, RTM-ECC-WM indicated higher strength degradation due to the load transferring effect of wire mesh than RTM-ECC.
引用
收藏
页码:411 / 424
页数:14
相关论文
共 50 条
  • [21] Enhancing the out-of-plane behaviour of unreinforced masonry walls under impact loading through the use of partially bonded layers of engineered cementitious composite
    Pourfalah, Saeed
    Cotsovos, Demetrios M.
    INTERNATIONAL JOURNAL OF PROTECTIVE STRUCTURES, 2020, 11 (02) : 209 - 234
  • [22] Seismic Strengthening of Unreinforced Masonry Walls using Sprayable Eco-Friendly Ductile Cementitious Composite (EDCC)
    Soleimani-Dashtaki, Salman
    Ventura, Carlos E.
    Banthia, Nemkumar
    PERFORMANCE OF MATERIALS AND STRUCTURES UNDER EXTREME CONDITIONS, 2017, 210 : 154 - 164
  • [23] Out-of-plane behavior of unreinforced masonry walls strengthened with FRP strips
    Hamed, E.
    Rabinovitch, O.
    COMPOSITES SCIENCE AND TECHNOLOGY, 2007, 67 (3-4) : 489 - 500
  • [24] Field assessment of unreinforced masonry walls strengthened with fiber reinforced polymer laminates
    Tumialan, JG
    Galati, N
    Nanni, A
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2003, 129 (08): : 1047 - 1056
  • [25] Lateral Force-Displacement Response of Unreinforced Masonry Walls with Flanges
    Russell, A. P.
    Elwood, K. J.
    Ingham, J. M.
    JOURNAL OF STRUCTURAL ENGINEERING, 2014, 140 (04)
  • [26] Determination of partial resistance factors for unreinforced masonry shear walls
    Jaeger, Wolfram
    Salehi, Hamidreza
    MAUERWERK, 2019, 23 (04) : 227 - 231
  • [27] Behaviour of masonry walls strengthened with fibre-reinforced cementitious materials
    Celano, Thomas
    Ceroni, Francesca
    Lignola, Gian Piero
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-ENGINEERING AND COMPUTATIONAL MECHANICS, 2021, 174 (04) : 193 - 214
  • [28] Out-of-Plane lateral load capacity of unreinforced masonry walls
    Hwang, S. H.
    Kim, S.
    Choi, Y. S.
    Yang, K. H.
    JOURNAL OF STRUCTURAL INTEGRITY AND MAINTENANCE, 2022, 7 (04) : 217 - 225
  • [29] Experimental in-plane cyclic response of unreinforced masonry walls versus strengthened walls using jacketing
    Hrasnica, M.
    Ademovic, N.
    Medic, S.
    Biberkic, F.
    BRICK AND BLOCK MASONRY: TRENDS, INNOVATIONS AND CHALLENGES, 2016, : 2091 - 2098
  • [30] Experimental investigation on the performance of unreinforced masonry wall, retrofitted using engineered cementitious composites
    Niasar, Alireza Namayandeh
    Alaee, Farshid Jandaghi
    Zamani, Sohail Majid
    CONSTRUCTION AND BUILDING MATERIALS, 2020, 239