Improved free-air ionization chamber for the measurement of x-rays

被引:8
|
作者
Chen, WL [1 ]
Su, SH [1 ]
Su, LL [1 ]
Hwang, WS [1 ]
机构
[1] Inst Nucl Energy Res, Lungtan 325, Hsiang, Taiwan
关键词
D O I
10.1088/0026-1394/36/1/4
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Based on an original design by F. H. Attix, an improved free-air ionization chamber was constructed at the National Radiation Standard Laboratory of the Institute of Nuclear Energy Research (INER, Taiwan), as the primary standard for x-rays generated at energy levels between 50 keV and 300 keV. Various improvements were made to the Attix design, including modifications of the chamber structure and the measurement technique. The changes include: (i) a three-section design with fixed central cylinder; (ii) thickening of the shielding box; (iii) a circuitous mechanism for the operational handle, to avoid unwanted scattering; (iv) a ruler mechanism to provide fine position control; and (v) increased thickness of the aluminium wall of the chamber. After initial experimental verification, a comparison with the National Institute of Standards and Technology (NIST, USA) using a transfer standard chamber yielded differences in calibration factors of less than 1%. In addition, the overall uncertainty for the x-ray measurement in terms of air kerma is less than 1% at the 95% confidence level. These results indicate that the improved free-air ionization chamber can serve as a primary standard at the NRSL.
引用
收藏
页码:19 / 24
页数:6
相关论文
共 50 条
  • [1] Measurement of supervoltage x-rays with the free-air ionization chamber
    Taylor, LS
    Singer, G
    Charlton, AL
    AMERICAN JOURNAL OF ROENTGENOLOGY AND RADIUM THERAPY, 1939, 41 : 256 - 275
  • [2] Measurement of supervoltage X-rays with the free-air ionization chamber
    Taylor, LS
    Singer, G
    Charlton, AL
    JOURNAL OF RESEARCH OF THE NATIONAL BUREAU OF STANDARDS, 1938, 21 (01): : 19 - 44
  • [3] EFFECTS OF SCATTERED X-RAYS AND FLUORESCENCES ON EXPOSURE MEASURED WITH A FREE-AIR IONIZATION-CHAMBER
    TAKATA, N
    SAKIHARA, K
    RADIATION PROTECTION DOSIMETRY, 1985, 11 (01) : 53 - 56
  • [4] The performance of the INER improved free-air ionization chamber in the comparison of air kerma calibration coefficients for medium-energy X-rays
    Lee, JH
    Kotler, LH
    Büermann, L
    Hwang, WS
    Chiu, JH
    Wang, CF
    RADIATION MEASUREMENTS, 2005, 39 (01) : 1 - 10
  • [5] THE CANADIAN STANDARD FREE-AIR CHAMBER FOR MEDIUM QUALITY X-RAYS
    HENRY, WH
    GARRETT, C
    CANADIAN JOURNAL OF PHYSICS, 1960, 38 (12) : 1677 - 1689
  • [6] Diaphragm correction factors for free-air chamber standards for air kerma in x-rays
    Burns, D. T.
    Kessler, C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (09): : 2737 - 2745
  • [7] AN AIR IONIZATION CHAMBER FOR SOFT X-RAYS
    SEEMANN, HE
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1949, 20 (12): : 903 - 907
  • [8] Characterization of a free air ionization chamber for low energy X-rays
    Silva, N. F.
    Xavier, M.
    Vivolo, V.
    Caldas, L. V. E.
    8TH BRAZILIAN CONGRESS ON METROLOGY (METROLOGIA 2015), 2016, 733
  • [9] NBS FREE-AIR CHAMBER FOR MEASUREMENT OF 10 TO 60 KV X RAYS
    LAMPERTI, PJ
    WYCKOFF, HO
    JOURNAL OF RESEARCH OF THE NATIONAL BUREAU OF STANDARDS SECTION C-ENGINEERING AND INSTRUMENTATION, 1965, C 69 (01): : 39 - +
  • [10] THE NEW NPL STANDARD FREE-AIR IONIZATION-CHAMBER FOR X-RAYS GENERATED AT UP TO 50KV
    MARSH, ARS
    PHYSICS IN MEDICINE AND BIOLOGY, 1980, 25 (05): : 949 - 949