Finite element formulation and shaking table tests of direction-optimized-friction-pendulum system

被引:43
|
作者
Tsai, C. S. [1 ]
Lu, Po-Ching [2 ]
Chen, Wen-Shin [2 ]
Chiang, Tsu-Cheng [3 ]
Yang, Chen-Tsung [2 ]
Lin, Yung-Chang [2 ]
机构
[1] Feng Chia Univ, Dept Civil Engn, Taichung 40724, Taiwan
[2] Feng Chia Univ, Grad Inst Civil & Hydraul Engn, Taichung 40724, Taiwan
[3] Earthquake Proof Syst Inc, Taichung, Taiwan
关键词
structural dynamics; earthquake engineering; base isolation; isolator; friction pendulum system (FPS);
D O I
10.1016/j.engstruct.2007.12.023
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Recently, in several countries the application of base isolation technology has already been proven as the effective and economically viable method to enhance the capability of structures in seismic mitigation. In this study, an advanced base isolation system called the direction-optimized-friction-pendulum system (DO-FPS) is proposed and investigated to determine its mechanical behavior through finite element formulation and examine its efficiency in seismic mitigation by conducting the shaking table test. Based on finite element formulation, we infer that the natural period, the capacity of the bearing displacement and damping effect for a DO-FPS isolator change continually during earthquakes. Therefore, DO-FPS can avoid the resonance and provide an effective capacity for bearing displacement and damping during the earthquakes. Simultaneously, the shaking table test also illustrates that DO-FPS possesses outstanding seismic mitigation capabilities. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2321 / 2329
页数:9
相关论文
共 50 条
  • [41] Mass rig system for shaking table tests of slender columns
    Silva, Pedro F.
    Sangtarashha, Arash
    Burgueno, Rigoberto
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2015, 44 (15): : 2717 - 2736
  • [42] Shaking table tests of mock transformer-bushing system
    Zhu, R., 1600, Power System Technology Press (37):
  • [43] Tri-directional shaking table tests of vibration sensitive equipment with static dynamics interchangeable-ball pendulum system
    C.S.Tsai
    Wen-Shin Chen
    EarthquakeEngineeringandEngineeringVibration, 2010, 9 (01) : 103 - 112
  • [44] Tri-directional shaking table tests of vibration sensitive equipment with static dynamics interchangeable-ball pendulum system
    C. S. Tsai
    Yung-Chang Lin
    Wen-Shin Chen
    H. C. Su
    Earthquake Engineering and Engineering Vibration, 2010, 9 : 103 - 112
  • [45] Tri-directional shaking table tests of vibration sensitive equipment with static dynamics interchangeable-ball pendulum system
    Tsai, C. S.
    Lin, Yung-Chang
    Chen, Wen-Shin
    Su, H. C.
    EARTHQUAKE ENGINEERING AND ENGINEERING VIBRATION, 2010, 9 (01) : 103 - 112
  • [46] Seismic Experimental Assessment of Remote Terminal Unit System with Friction Pendulum under Triaxial Shake Table Tests
    Kim, Sung-Wan
    Jeon, Bub-Gyu
    Yun, Da-Woon
    Jung, Woo-Young
    Ju, Bu-Seog
    METALS, 2021, 11 (09)
  • [47] Active optimal control of SSI system based on the finite element model of SSI system and shaking table test study
    Wang, F. X.
    Ou, J. P.
    ACTIVE AND PASSIVE SMART STRUCTURES AND INTEGRATED SYSTEMS 2008, 2008, 6928
  • [48] Dry friction behaviour of a geosynthetic interface using inclined plane and shaking table tests
    Carbone, L.
    Gourc, J. P.
    Carrubba, P.
    Pavanello, P.
    Moraci, N.
    GEOTEXTILES AND GEOMEMBRANES, 2015, 43 (04) : 293 - 306
  • [49] Mathematical Formulation of Friction Pendulum System With Multiple Sliding Interfaces
    Jurcau, Stefania Camelia
    Iancu, Vasile
    Jurcau, Lazar
    ROMANIAN JOURNAL OF ACOUSTICS AND VIBRATION, 2011, 8 (01): : 41 - 46
  • [50] AN INVESTIGATION ON THE DYNAMIC RESPONSE OF THE SHAKING TABLE STEEL DECK USING FINITE ELEMENT
    Moghaddam, Hassan
    Farzanian, Khashayar
    Taheri, Ehsan
    11TH WORLD CONGRESS ON COMPUTATIONAL MECHANICS; 5TH EUROPEAN CONFERENCE ON COMPUTATIONAL MECHANICS; 6TH EUROPEAN CONFERENCE ON COMPUTATIONAL FLUID DYNAMICS, VOLS II - IV, 2014, : 1330 - 1340