Seismic Experimental Assessment of Remote Terminal Unit System with Friction Pendulum under Triaxial Shake Table Tests

被引:4
|
作者
Kim, Sung-Wan [1 ]
Jeon, Bub-Gyu [1 ]
Yun, Da-Woon [1 ]
Jung, Woo-Young [2 ]
Ju, Bu-Seog [3 ]
机构
[1] Pusan Natl Univ, Seism Res & Test Ctr, Yangsan Si 50612, South Korea
[2] Gangneung Wonju Natl Univ, Dept Civil Engn, Gangneung Si 25457, South Korea
[3] Kyung Hee Univ, Dept Civil Engn, Yongin 17104, South Korea
关键词
electrical cabinet; triaxial shake table; friction pendulum; seismic isolated device; ELECTRICAL CABINET; PERFORMANCE;
D O I
10.3390/met11091428
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In recent years, earthquakes have caused more damage to nonstructural components, such as mechanical and electrical equipment and piping systems, than to structural components. In particular, among the nonstructural components, the electrical cabinet is an essential piece of equipment used to maintain the functionality of critical facilities such as nuclear and non-nuclear power plants. Therefore, damage to the electrical cabinet associated with the safety of the facility can lead to severe accidents related to loss-of-life and property damage. Consequently, the electrical cabinet system must be protected against strong ground motion. This paper presents an exploratory study of dynamic characteristics of seismically isolated remote terminal unit (RTU) cabinet system subjected to tri-axial shaking table, and also the shaking table test of the non-seismically isolated cabinet system was conducted to compare the vibration characteristics with the cabinet system installed with friction pendulum isolator device. In addition, for the shaking table test, two recorded earthquakes obtained from Korea and artificial earthquakes based on the common application of building seismic-resistant design standards as an input ground motions were applied. The experimental assessment showed that the various damage modes such as door opening, the fall of the wire mold, and damage to door lock occurred in the RTU panel fixed on the concrete foundation by a set anchor, but the damage occurred only at the seismic isolator in the seismically isolated RTU panel system. Furthermore, it was considered that the application of the seismic isolator can effectively mitigate the impact and amplification of seismic force to the RTU panel system during and after strong ground motions in this study.
引用
收藏
页数:26
相关论文
共 50 条
  • [1] Shake table tests for seismic assessment of suspended continuous ceilings
    Magliulo, Gennaro
    Pentangelo, Vincenzo
    Maddaloni, Giuseppe
    Capozzi, Vittorio
    Petrone, Crescenzo
    Lopez, Pauline
    Talamonti, Renato
    Manfredi, Gaetano
    BULLETIN OF EARTHQUAKE ENGINEERING, 2012, 10 (06) : 1819 - 1832
  • [2] Shake table tests for seismic assessment of suspended continuous ceilings
    Gennaro Magliulo
    Vincenzo Pentangelo
    Giuseppe Maddaloni
    Vittorio Capozzi
    Crescenzo Petrone
    Pauline Lopez
    Renato Talamonti
    Gaetano Manfredi
    Bulletin of Earthquake Engineering, 2012, 10 : 1819 - 1832
  • [3] SHAKE TABLE TESTS TO EXAMINE THE SEISMIC PERFORMANCE OF STEEL UNIT HOUSES
    Matsuda R.
    Okazaki T.
    Nagae T.
    Matsumiya T.
    Kanzaki Y.
    Fukui T.
    Iijima T.
    Kiriyama Y.
    Kajiwara K.
    AIJ Journal of Technology and Design, 2022, 28 (68) : 209 - 214
  • [4] Shake table testing on restoring capability of double concave friction pendulum seismic isolation systems
    Ponzo, Felice Carlo
    Di Cesare, Antonio
    Leccese, Gianmarco
    Nigro, Domenico
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2017, 46 (14): : 2337 - 2353
  • [5] Experimental Investigation of Seismic Uncertainty Propagation through Shake Table Tests
    Deng, Peng
    Pei, Shiling
    van de Lindt, John W.
    Zhang, Chao
    JOURNAL OF STRUCTURAL ENGINEERING, 2018, 144 (03)
  • [6] Shake Table Tests to Examine the Seismic Performance of Prefabricated Steel Unit Houses
    Matsuda, Ryosuke
    Okazaki, Taichiro
    Nagae, Takuya
    Matsumiya, Tomohiro
    Kanzaki, Yoshikazu
    Fukui, Takahiro
    Iijima, Toshihiko
    Kiriyama, Yoshiro
    Kajiwara, Koichi
    Lecture Notes in Civil Engineering, 2022, 262 LNCE : 1116 - 1123
  • [7] Shake Table Tests to Examine the Seismic Performance of Prefabricated Steel Unit Houses
    Matsuda, Ryosuke
    Okazaki, Taichiro
    Nagae, Takuya
    Matsumiya, Tomohiro
    Kanzaki, Yoshikazu
    Fukui, Takahiro
    Iijima, Toshihiko
    Kiriyama, Yoshiro
    Kajiwara, Koichi
    PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON BEHAVIOUR OF STEEL STRUCTURES IN SEISMIC AREAS, STESSA 2022, 2022, 262 : 1116 - 1123
  • [8] Shake table tests for the seismic assessment of hollow brick internal partitions
    Petrone, Crescenzo
    Magliulo, Gennaro
    Manfredi, Giuseppe
    ENGINEERING STRUCTURES, 2014, 72 : 203 - 214
  • [9] Seismic evaluation of two-elevation ceiling system by shake table tests
    Qi, Liangjie
    Kurata, Masahiro
    Ikeda, Yoshiki
    Kunitomo, Keiichiro
    Takaoka, Masashi
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2021, 50 (04): : 1147 - 1166
  • [10] Experimental assessment of the seismic performance of hospital cabinets using shake table testing
    Di Sarno, Luigi
    Magliulo, Gennaro
    D'Angela, Danilo
    Cosenza, Edoardo
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2019, 48 (01): : 103 - 123