Seismic Experimental Assessment of Remote Terminal Unit System with Friction Pendulum under Triaxial Shake Table Tests

被引:4
|
作者
Kim, Sung-Wan [1 ]
Jeon, Bub-Gyu [1 ]
Yun, Da-Woon [1 ]
Jung, Woo-Young [2 ]
Ju, Bu-Seog [3 ]
机构
[1] Pusan Natl Univ, Seism Res & Test Ctr, Yangsan Si 50612, South Korea
[2] Gangneung Wonju Natl Univ, Dept Civil Engn, Gangneung Si 25457, South Korea
[3] Kyung Hee Univ, Dept Civil Engn, Yongin 17104, South Korea
关键词
electrical cabinet; triaxial shake table; friction pendulum; seismic isolated device; ELECTRICAL CABINET; PERFORMANCE;
D O I
10.3390/met11091428
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In recent years, earthquakes have caused more damage to nonstructural components, such as mechanical and electrical equipment and piping systems, than to structural components. In particular, among the nonstructural components, the electrical cabinet is an essential piece of equipment used to maintain the functionality of critical facilities such as nuclear and non-nuclear power plants. Therefore, damage to the electrical cabinet associated with the safety of the facility can lead to severe accidents related to loss-of-life and property damage. Consequently, the electrical cabinet system must be protected against strong ground motion. This paper presents an exploratory study of dynamic characteristics of seismically isolated remote terminal unit (RTU) cabinet system subjected to tri-axial shaking table, and also the shaking table test of the non-seismically isolated cabinet system was conducted to compare the vibration characteristics with the cabinet system installed with friction pendulum isolator device. In addition, for the shaking table test, two recorded earthquakes obtained from Korea and artificial earthquakes based on the common application of building seismic-resistant design standards as an input ground motions were applied. The experimental assessment showed that the various damage modes such as door opening, the fall of the wire mold, and damage to door lock occurred in the RTU panel fixed on the concrete foundation by a set anchor, but the damage occurred only at the seismic isolator in the seismically isolated RTU panel system. Furthermore, it was considered that the application of the seismic isolator can effectively mitigate the impact and amplification of seismic force to the RTU panel system during and after strong ground motions in this study.
引用
收藏
页数:26
相关论文
共 50 条
  • [21] First Trial of a Mechanical System for Experimental Shake Table Dynamic Tests on Real Scale Structures
    Dacarro, Filippo
    Peloso, Simone
    Bolognini, Davide
    Furinghetti, Marco
    Calvi, Gian Michele
    JOURNAL OF EARTHQUAKE ENGINEERING, 2024, 28 (01) : 85 - 111
  • [22] Characterization and shaking table tests of multiple trench friction pendulum system with numerous intermediate sliding plates
    Tsai, C. S.
    Lin, Yung-Chang
    STRUCTURAL ENGINEERING AND MECHANICS, 2011, 40 (02) : 167 - 190
  • [23] Shaking table test to investigate the size effect on the seismic response of a low-cost friction pendulum system
    Firdaus, Putri S.
    Akiyama, Mitsuyoshi
    Kashiyama, Hiroki
    Brito, Miguel B.
    Takahashi, Hirokazu
    Ishigaki, Naomitsu
    Honda, Riki
    STRUCTURE AND INFRASTRUCTURE ENGINEERING, 2023,
  • [24] Performance Evaluation of Negative Stiffness Devices for Seismic Response Control of Bridge Structures via Experimental Shake Table Tests
    Attary, N.
    Symans, M.
    Nagarajaiah, S.
    Reinhorn, A. M.
    Constantinou, M. C.
    Sarlis, A. A.
    Pasala, D. T. R.
    Taylor, D.
    JOURNAL OF EARTHQUAKE ENGINEERING, 2015, 19 (02) : 249 - 276
  • [25] Damage Assessment of a Full-Scale Six-Story Wood-Frame Building Following Triaxial Shake Table Tests
    van de Lindt, John W.
    Gupta, Rakesh
    Pei, Shiling
    Tachibana, Kazuki
    Araki, Yasuhiro
    Rammer, Douglas
    Isoda, Hiroshi
    JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES, 2012, 26 (01) : 17 - 25
  • [26] Shake table tests for the seismic performance assessment of desktop medical laboratory equipment considering the effect of adjacent walls and restrainers
    Yu, Peng
    Zhai, Changhai
    Liu, Jin
    Wang, Xiaoting
    STRUCTURES, 2023, 50 : 1922 - 1933
  • [27] SEISMIC MITIGATION ASSESSMENT OF BUILDING USING MULTIPLE DIRECTION OPTIMIZED-FRICTION PENDULUM SYSTEM
    Tsai, C. S.
    Chen, Wen-Shin
    Lin, Yung-Chang
    Lin, Chi-Lu
    PROCEEDINGS OF THE ASME PRESSURE VESSELS AND PIPING CONFERENCE, VOL 8: SEISMIC ENGINEERING, 2009, : 149 - 158
  • [28] Shake table tests of a new steel-asphalt composite layer system for the seismic base isolation of housing units
    Yao, Fei
    Shang, Shouping
    Liu, Ke
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2014, 59 : 1 - 7
  • [29] Mitigation of liquefaction-induced hazard using geosynthetics: An experimental study using cyclic triaxial and large-scale shake table tests
    Rajiv Chauhan
    Satyendra Mittal
    Vaibhav Sharma
    Innovative Infrastructure Solutions, 2022, 7
  • [30] Mitigation of liquefaction-induced hazard using geosynthetics: An experimental study using cyclic triaxial and large-scale shake table tests
    Chauhan, Rajiv
    Mittal, Satyendra
    Sharma, Vaibhav
    INNOVATIVE INFRASTRUCTURE SOLUTIONS, 2022, 7 (06)