Development and evaluation of a new assistive device for low back load reduction in caregivers: an experimental study

被引:4
|
作者
Omura, Yuka [1 ,2 ]
Hirata, Masayuki [3 ,4 ]
Yoshimine, Toshiki [4 ,5 ]
Nakatani, Eiji [6 ,7 ]
Inoue, Tomoko [1 ]
机构
[1] Osaka Univ, Div Hlth Sci, Grad Sch Med, Osaka, Japan
[2] Osaka Univ, Global Ctr Med Engn & Informat, Osaka, Japan
[3] Osaka Univ, Dept Neurol Diag & Restorat, Grad Sch Med, Osaka, Japan
[4] Osaka Univ, Global Ctr Med Engn & Informat, Endowed Res Dept Clin Neuroengn, Osaka, Japan
[5] Iseikai Med Corp, Osaka, Japan
[6] Shizuoka Grad Univ Publ Hlth, Grad Sch Publ Hlth Med Stat, Shizuoka, Japan
[7] Shizuoka Prefectural Gen Hosp, Res Support Ctr, Div Clin Biostat, Shizuoka, Japan
关键词
HEART-RATE RECOVERY; PHYSICAL-ACTIVITY; BIOMECHANICAL EVALUATION; NURSING PERSONNEL; PATIENT; FATIGUE; POSTURE; TRUNK; PAIN; DISORDERS;
D O I
10.1038/s41598-022-21800-5
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Low back pain among healthcare professionals is associated with the manual handling of patients. Some bed features for turning and repositioning have been developed; however, the load during patient care remains heavy. We developed a device to reduce low back load in caregivers during patient bedside care and evaluated it objectively and subjectively from a caregiver's perspective using a randomised crossover study. Overall, 28 clinical nurses and care workers were randomly assigned to two interventional groups: administering care with (Device method) and without (Manual method) the device in an experimental room. We measured the caregiver's trunk flexion angle using inertial measurement units and video recording during care and then defined a trunk flexion angle of > 45 degrees as the threshold; the variables were analysed using linear mixed models. Subsequently, participants responded to a survey regarding the usability of the device. Trunk flexion time and percentage of time were 26.5 s (95% confidence interval: 14.1 s, 38.9 s) (p < 0.001) and 23.0% (95% confidence interval: 16.4%, 29.6%) (p < 0.001) lower, respectively, in the Device group than in the Manual group. Furthermore, caregivers evaluated the care they could administer with the device as being better than that associated with manual care.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Cumulative Low Back Load at Work as a Risk Factor of Low Back Pain: A Prospective Cohort Study
    Pieter Coenen
    Idsart Kingma
    Cécile R. L. Boot
    Jos W. R. Twisk
    Paulien M. Bongers
    Jaap H. van Dieën
    Journal of Occupational Rehabilitation, 2013, 23 : 11 - 18
  • [32] Experimental Study on Rocket Nozzle Side Load Reduction
    Stark, Ralf H.
    Genin, Chloe
    JOURNAL OF PROPULSION AND POWER, 2012, 28 (02) : 307 - 311
  • [33] Cumulative Low Back Load at Work as a Risk Factor of Low Back Pain: A Prospective Cohort Study
    Coenen, Pieter
    Kingma, Idsart
    Boot, Cecile R. L.
    Twisk, Jos W. R.
    Bongers, Paulien M.
    van Dieen, Jaap H.
    JOURNAL OF OCCUPATIONAL REHABILITATION, 2013, 23 (01) : 11 - 18
  • [34] MODEL DEVELOPMENT, REDUCTION, AND EXPERIMENTAL EVALUATION FOR AN EVAPORATOR
    NEWELL, RB
    FISHER, DG
    INDUSTRIAL & ENGINEERING CHEMISTRY PROCESS DESIGN AND DEVELOPMENT, 1972, 11 (02): : 213 - +
  • [35] Work load reduction through a new roll container traction device
    Plantenga, RA
    Voorbij, AIM
    Snijders, CJ
    Voorbach, H
    DISABILITY AND REHABILITATION, 2003, 25 (4-5) : 242 - 246
  • [36] Development of new endoscopic irreversible electroporation ablation device: Animal experimental study
    Woojung, Kim
    Geeho, Min
    Ji, Choi Seong
    Yup, Lee Sang
    Jai, Chun Hoon
    Min, Lee Jung
    Kyung, Yoo In
    Min, Lee Jae
    Han, Kim Seung
    Soon, Choi Hyuk
    Sun, Kim Eun
    Bora, Keum
    Tae, Jeen Yoon
    Sik, Lee Hong
    Duck, Kim Chang
    ANNALS OF ONCOLOGY, 2017, 28
  • [37] Development of an Imaging Evaluation System for Low Back Pain
    Ping-En Sun
    Bing-Shiang Yang
    Journal of Medical and Biological Engineering, 2021, 41 : 92 - 98
  • [38] Development of Experimental Device for Compression Load Deflection of Car Door Seals
    赵建才
    朱训生
    万德安
    Journal of DongHua University, 2003, (02) : 116 - 121
  • [39] Development of an Imaging Evaluation System for Low Back Pain
    Sun, Ping-En
    Yang, Bing-Shiang
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2021, 41 (01) : 92 - 98
  • [40] An experimental study to inform adoption of mindfulness-based stress reduction in chronic low back pain
    Jones, Salene M. W.
    Sherman, Karen J.
    Bermet, Zoe
    Palazzo, Lorella G.
    Lewis, Cara C.
    IMPLEMENTATION SCIENCE COMMUNICATIONS, 2022, 3 (01):