Development and evaluation of a new assistive device for low back load reduction in caregivers: an experimental study

被引:4
|
作者
Omura, Yuka [1 ,2 ]
Hirata, Masayuki [3 ,4 ]
Yoshimine, Toshiki [4 ,5 ]
Nakatani, Eiji [6 ,7 ]
Inoue, Tomoko [1 ]
机构
[1] Osaka Univ, Div Hlth Sci, Grad Sch Med, Osaka, Japan
[2] Osaka Univ, Global Ctr Med Engn & Informat, Osaka, Japan
[3] Osaka Univ, Dept Neurol Diag & Restorat, Grad Sch Med, Osaka, Japan
[4] Osaka Univ, Global Ctr Med Engn & Informat, Endowed Res Dept Clin Neuroengn, Osaka, Japan
[5] Iseikai Med Corp, Osaka, Japan
[6] Shizuoka Grad Univ Publ Hlth, Grad Sch Publ Hlth Med Stat, Shizuoka, Japan
[7] Shizuoka Prefectural Gen Hosp, Res Support Ctr, Div Clin Biostat, Shizuoka, Japan
关键词
HEART-RATE RECOVERY; PHYSICAL-ACTIVITY; BIOMECHANICAL EVALUATION; NURSING PERSONNEL; PATIENT; FATIGUE; POSTURE; TRUNK; PAIN; DISORDERS;
D O I
10.1038/s41598-022-21800-5
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Low back pain among healthcare professionals is associated with the manual handling of patients. Some bed features for turning and repositioning have been developed; however, the load during patient care remains heavy. We developed a device to reduce low back load in caregivers during patient bedside care and evaluated it objectively and subjectively from a caregiver's perspective using a randomised crossover study. Overall, 28 clinical nurses and care workers were randomly assigned to two interventional groups: administering care with (Device method) and without (Manual method) the device in an experimental room. We measured the caregiver's trunk flexion angle using inertial measurement units and video recording during care and then defined a trunk flexion angle of > 45 degrees as the threshold; the variables were analysed using linear mixed models. Subsequently, participants responded to a survey regarding the usability of the device. Trunk flexion time and percentage of time were 26.5 s (95% confidence interval: 14.1 s, 38.9 s) (p < 0.001) and 23.0% (95% confidence interval: 16.4%, 29.6%) (p < 0.001) lower, respectively, in the Device group than in the Manual group. Furthermore, caregivers evaluated the care they could administer with the device as being better than that associated with manual care.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Development of Mechanical Load Adjusting Device with Motion Measurement Interface for Robotic Assistive Rehabilitation System
    Tsumugiwa, Toru
    Watanabe, Yuki
    Yokogawa, Ryuichi
    2009 IEEE 11TH INTERNATIONAL CONFERENCE ON REHABILITATION ROBOTICS, VOLS 1 AND 2, 2009, : 141 - +
  • [22] Wearable Assistive Device for Physical Load Reduction of Caregiver - Adaptive to Caregiver's Motion during Transferring Support
    Hasegawa, Yasuhisa
    Hoshino, Takashi
    Tsukahara, Atsushi
    2016 WORLD AUTOMATION CONGRESS (WAC), 2016,
  • [23] Development and experimental study on transfusion device
    Duan, Zeyu
    Liu, Guangjun
    Wang, Fang
    Sun, Chuanxing
    2020 5TH INTERNATIONAL CONFERENCE ON MECHANICAL, CONTROL AND COMPUTER ENGINEERING (ICMCCE 2020), 2020, : 373 - 377
  • [24] Design and Development of Low-Cost Assistive Device for Lower Limb Exoskeleton Robot
    Sanngoen, Wanayuth
    Nillnawarad, Setawichock
    Patchim, Sema
    2017 10TH INTERNATIONAL CONFERENCE ON HUMAN SYSTEM INTERACTIONS (HSI), 2017, : 148 - 153
  • [25] Development and Evaluation of Shoe-type Walking Assistive Device for Visually Impaired Person
    Yang, Chang-Min
    Jung, Ji-Yong
    Kim, Jung-Ja
    SENSORS AND MATERIALS, 2018, 30 (08) : 1869 - 1876
  • [26] Preliminary development and evaluation of a mechanical handwriting assistive device to support individuals with movement disorders
    Lemire, Gabrielle
    Laliberte, Thierry
    Turcot, Katia
    Flamand, Veronique H.
    Campeau-Lecours, Alexandre
    FRONTIERS IN REHABILITATION SCIENCES, 2025, 5
  • [27] Development and Performance Evaluation of Parallel Link Type Human Ankle Rehabilitation Assistive Device
    Yonezawa, Teru
    Nomura, Kenta
    Onodera, Takayuki
    Ding, Ming
    Mizoguchi, Hiroshi
    Takemura, Hiroshi
    2014 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND BIOMIMETICS IEEE-ROBIO 2014, 2014, : 802 - 807
  • [28] Development and Evaluation of a Wearable Upper Limb Assistive Device with a Remote Center of Motion Mechanism
    Nakamura, Seishiro
    Sun, Yi
    Osawa, Keisuke
    Tanaka, Eiichiro
    JOURNAL OF ROBOTICS AND MECHATRONICS, 2024, 36 (05) : 1191 - 1207
  • [29] Study of Current Emotion and Muscle Fatigue Evaluation Method for a Walking Assistive Device
    Yang, Jun Yan
    Zhuang, Jyun Rong
    Wu, Guan Yu
    Tanaka, Eiichiro
    2020 IEEE/ASME INTERNATIONAL CONFERENCE ON ADVANCED INTELLIGENT MECHATRONICS (AIM), 2020, : 1884 - 1889
  • [30] Acceleration-based Assistive Strategy to Control a Back-support Exoskeleton for Load Handling: Preliminary Evaluation
    Lazzaroni, Maria
    Toxiri, Stefano
    Caldwell, Darwin G.
    Anastasi, Sara
    Monica, Luigi
    De Momi, Elena
    Ortiz, Jesus
    2019 IEEE 16TH INTERNATIONAL CONFERENCE ON REHABILITATION ROBOTICS (ICORR), 2019, : 625 - 630