Comparison of Primary Stability of Straight-Walled and Tapered Implants Using an Insertion Torque Device

被引:0
|
作者
Menicucci, Giulio [1 ]
Pachie, Emanuela
Lorenzetti, Massimo
Migliaretti, Giuseppe [2 ]
Carossa, Stefano
机构
[1] Univ Turin, Dipartimento Sci Biomed & Oncol Umana, Sez Riabilitaz Orale & Protesi Maxillofaciale, Sch Dent, I-10126 Turin, Italy
[2] Univ Turin, Dept Publ Hlth & Microbiol, Stat Unit, I-10126 Turin, Italy
关键词
RESONANCE FREQUENCY; TITANIUM IMPLANTS; BONE-DENSITY; IN-VITRO; INTEGRATION; PLACEMENT; BRANEMARK; DIAMETER; MOBILITY;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: Implant geometry has a major impact on insertion torque values and primary stability, and bone engagement during implant insertion differs according to implant morphology. Primary stability of straight-walled and tapered implants was compared using insertion torque monitoring. Materials and Methods: A total of 57 implants (36 straight-walled OSSEOTITE and 21 tapered OSSEOTITE NT) were inserted in 20 patients. Implant torque values and insertion times were recorded, and the data were processed and interpolated to determine torque as a function of time. Results: Tapered implants required less insertion time and a higher insertion torque than straight-walled implants; this provided better primary stability, although the success rate was 86% for tapered and 100% for straight-walled implants. Conclusions: Tapered implants showed better primary stability than straight-walled implants but had a lower success rate. The authors suggest that in low-density bone, in which only a thin dense cortical layer can contribute to primary stability, a higher insertion torque can lead to the destruction of pen-implant bone, compromising osseointegration. Int J Prosthodont 2012;25:465-471.
引用
收藏
页码:465 / 471
页数:7
相关论文
共 50 条
  • [41] Optimizing the primary stability of dental implants in type IV bone: in-vitro comparison of machine-driven and ratcheting insertion protocols
    Taysi, Nuri Mert
    Taysi, Aysegul Erten
    Ercal, Pinar
    Sismanoglu, Soner
    EUROPEAN ORAL RESEARCH, 2025, 59 (01) : 46 - 52
  • [42] Primary Stability of Conventionally Tapered Versus Reverse Tapered Body Shift Implants Under Varying Bone Support Conditions—An In-Vitro Study
    Jeremy Pitman
    Véronique Christiaens
    Jan Cosyn
    Maarten Glibert
    Journal of Medical and Biological Engineering, 2022, 42 : 429 - 435
  • [43] Response to letter to the editor: Re: Stability of tapered and parallel-walled dental implants: A systematic review and meta-analysis
    Atieh, Momen A.
    Alsabeeha, Nabeel H. M.
    Duncan, Warwick
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2023, 25 (06) : 988 - 989
  • [44] Insertion Torque (IT) and Implant Stability Quotient (ISQ) Assessment in Dental Implants with and without Healing Chambers: A Polyurethane In Vitro Study
    Mello, Bruno Freitas
    Formiga, Marcio De Carvalho
    Bianchini, Marco Aurelio
    Borges Jr, Ivan
    Coura, Gustavo
    Tumedei, Margherita
    Fuller, Renato
    Petrini, Morena
    Romasco, Tea
    Vaz, Paula
    Piattelli, Adriano
    Di Pietro, Natalia
    APPLIED SCIENCES-BASEL, 2023, 13 (18):
  • [45] Resonance-frequency-analysis and torque-measurement for evaluation of primary stability of dental implants.
    Al-Nawas, B
    Groetz, KA
    Brahm, R
    Wagner, W
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : B255 - B255
  • [46] Static in bone implants: standard steady-state torque and primary stability in a bioactive kinetic screw
    Andreucci, Carlos Aurelio
    Fonseca, Elza M. M.
    Jorge, Renato N.
    JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2023, 45 (12)
  • [47] Static in bone implants: standard steady-state torque and primary stability in a bioactive kinetic screw
    Carlos Aurelio Andreucci
    Elza M. M. Fonseca
    Renato N. Jorge
    Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2023, 45
  • [48] Evaluation of primary stability of cylindrical and tapered implants in different bone types by measuring implant displacement: An In vitro study
    Sugiura, Tsutomu
    Yamamoto, Kazuhiko
    Horita, Satoshi
    Murakami, Kazuhiro
    Kirita, Tadaaki
    CONTEMPORARY CLINICAL DENTISTRY, 2019, 10 (03) : 471 - 476
  • [49] Primary stability and bone deformation induced by tapered implants in different bone densities: a microtomography and resonance frequency analysis
    P. Faria
    A. Vieta
    F. A. Oliveira
    V. F. Carvalho
    S. L. S. Souza
    Mario Taba
    Periodontal and Implant Research, 9 (1)
  • [50] Primary Stability of Zirconia Dental Implants with Cylindrical and Tapered Designs Across Varying Bone Densities: An In Vitro Evaluation
    Fernandes, Diogo
    Cavaco, Francisco
    Freitas, Filipe
    Marques, Duarte
    Carames, Joao
    Moreira, Andre
    DENTISTRY JOURNAL, 2024, 12 (11)