Comparison of Primary Stability of Straight-Walled and Tapered Implants Using an Insertion Torque Device

被引:0
|
作者
Menicucci, Giulio [1 ]
Pachie, Emanuela
Lorenzetti, Massimo
Migliaretti, Giuseppe [2 ]
Carossa, Stefano
机构
[1] Univ Turin, Dipartimento Sci Biomed & Oncol Umana, Sez Riabilitaz Orale & Protesi Maxillofaciale, Sch Dent, I-10126 Turin, Italy
[2] Univ Turin, Dept Publ Hlth & Microbiol, Stat Unit, I-10126 Turin, Italy
关键词
RESONANCE FREQUENCY; TITANIUM IMPLANTS; BONE-DENSITY; IN-VITRO; INTEGRATION; PLACEMENT; BRANEMARK; DIAMETER; MOBILITY;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: Implant geometry has a major impact on insertion torque values and primary stability, and bone engagement during implant insertion differs according to implant morphology. Primary stability of straight-walled and tapered implants was compared using insertion torque monitoring. Materials and Methods: A total of 57 implants (36 straight-walled OSSEOTITE and 21 tapered OSSEOTITE NT) were inserted in 20 patients. Implant torque values and insertion times were recorded, and the data were processed and interpolated to determine torque as a function of time. Results: Tapered implants required less insertion time and a higher insertion torque than straight-walled implants; this provided better primary stability, although the success rate was 86% for tapered and 100% for straight-walled implants. Conclusions: Tapered implants showed better primary stability than straight-walled implants but had a lower success rate. The authors suggest that in low-density bone, in which only a thin dense cortical layer can contribute to primary stability, a higher insertion torque can lead to the destruction of pen-implant bone, compromising osseointegration. Int J Prosthodont 2012;25:465-471.
引用
收藏
页码:465 / 471
页数:7
相关论文
共 50 条
  • [31] Primary Stability of a Hybrid Implant Compared with Tapered and Cylindrical Implants in an Ex Vivo Model
    Toyoshima, Takeshi
    Tanaka, Hideaki
    Ayukawa, Yasunori
    Howashi, Miori
    Masuzaki, Tomohiro
    Kiyosue, Takahiro
    Koyano, Kiyoshi
    Nakamura, Seiji
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2015, 17 (05) : 950 - 956
  • [32] Primary Stability of Short Implants Inserted Using Piezoelectric or Drilling Systems: An In Vitro Comparison
    Stacchi, Claudio
    De Biasi, Matteo
    Torelli, Lucio
    Robiony, Massimo
    Di Lenarda, Roberto
    Angerame, Daniele
    JOURNAL OF ORAL IMPLANTOLOGY, 2019, 45 (04) : 259 - 266
  • [33] An In Vitro Analysis on Polyurethane Foam Blocks of the Insertion Torque (IT) Values, Removal Torque Values (RTVs), and Resonance Frequency Analysis (RFA) Values in Tapered and Cylindrical Implants
    Comuzzi, Luca
    Tumedei, Margherita
    D'Arcangelo, Camillo
    Piattelli, Adriano
    Iezzi, Giovanna
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (17)
  • [34] Dental Implants With Immediate Loading Using Insertion Torque of 30 Ncm: A Systematic Review
    Douglas de Oliveira, Dhelfeson Willya
    Lages, Frederico Santos
    Lanza, Leonardo Avellar
    Gomes, Alex Martins
    Queiroz, Thallita Pereira
    Costa, Fernando de Oliveira
    IMPLANT DENTISTRY, 2016, 25 (05) : 675 - 683
  • [35] Clinical study on the insertion torque and wireless resonance frequency analysis in the assessment of torque capacity and stability of self-tapping dental implants
    Kahraman, S.
    Bal, B. T.
    Asar, N. V.
    Turkyilmaz, I.
    Tozum, T. F.
    JOURNAL OF ORAL REHABILITATION, 2009, 36 (10) : 755 - 761
  • [36] A comparison between cutting torque and resonance frequency in the assessment of primary stability and final torque capacity of standard and TiUnite single tooth implants under immediate loading
    da Cunha, HA
    Francischone, CE
    Nary, H
    de Oliveira, RCG
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2004, 19 (04) : 578 - 585
  • [37] Impact of Insertion Depth and Predrilling Diameter on Primary Stability of Orthodontic Mini-implants
    Wilmes, Benedict
    Drescher, Dieter
    ANGLE ORTHODONTIST, 2009, 79 (04) : 609 - 614
  • [38] Correlation between ISQ and Insertion Torque values using double acid-etched implants
    Gallardo, Sebastian
    Constanza Ibanez, Maria
    Carlos Ibanez, Juan
    JOURNAL OF OSSEOINTEGRATION, 2016, 8 (03) : 29 - 36
  • [39] An In Vitro Comparison of the Primary Stability of 2 Tapered Fluted Femoral Stem Designs
    Vanhegan, Ivor S.
    Coathup, Melanie J.
    McCarthy, Ian
    Meswania, Jay
    Blunn, Gordon W.
    Haddad, Fares S.
    JOURNAL OF ARTHROPLASTY, 2016, 31 (02): : 517 - 523
  • [40] A Novel Technique for Osteotome Internal Sinus Lifts With Simultaneous Placement of Tapered Implants to Improve Primary Stability
    Petrov, Sofia D.
    Xing, Yi
    Khandelwal, Namita
    Drew, Howard J.
    JOURNAL OF ORAL IMPLANTOLOGY, 2014, 40 (05) : 607 - 614