Impact of patient rotational errors on target and critical structure dose in IMRT: A 3D simulation study

被引:0
|
作者
Arumugam, S. [1 ]
Xing, A. [1 ]
Vial, P. [1 ]
Scotti, A. [1 ]
Stirton, R. [1 ]
Goozee, G. [1 ]
Holloway, Lois [1 ]
机构
[1] Liverpool Hosp, Liverpool Canc Therapy Ctr, Sydney, NSW, Australia
关键词
IMAGE-GUIDED RADIOTHERAPY; LIMITATIONS;
D O I
10.1088/1742-6596/444/1/012045
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The impact of 3D rotational errors in patient positioning on dose delivered target volumes and critical structures in IMRT was studied. Patient rotational errors ranging from -3 degrees to +3 degrees was introduced to IMRT treatment plans of pelvis, head and neck and brain treatment sites and the impact of rotational error on DVH metrics was assessed. The magnitude of impact of rotational error on the error in dose delivered to the target volume and critical structures depends on the location of the structures from plan isocentre. In studied plans, a maximum percentage difference of up to -9.8(1s=13.4) % in D95 to PTV was observed for head and neck treatments. Similarly, in Brain treatments a maximum difference of up to 24.0(1s=33.0) % in maximum dose of Optic chiasm was observed. The results suggest that failure to correct patient's rotational error results in under-dosage to target volumes and over-dosage to the critical structures in some specific treatment scenarios.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Patient specific 3D printed phantom for IMRT quality assurance
    Ehler, Eric D.
    Barney, Brett M.
    Higgins, Patrick D.
    Dusenbery, Kathryn E.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (19): : 5763 - 5773
  • [22] PATIENT-SPECIFIC 3D PRETREATMENT AND POTENTIAL 3D ONLINE DOSE VERIFICATION OF MONTE CARLO-CALCULATED IMRT PROSTATE TREATMENT PLANS
    Boggula, Ramesh
    Jahnke, Lennart
    Wertz, Hansjoerg
    Lohr, Frank
    Wenz, Frederik
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (04): : 1168 - 1175
  • [23] 3D simulation of the impact made by a noncentral laser pulse on a spherical tin target
    Krukovskiy A.Y.
    Novikov V.G.
    Tsygvintsev I.P.
    Mathematical Models and Computer Simulations, 2017, 9 (1) : 48 - 59
  • [24] A feasibility study to predict 3D dose delivery accuracy for IMRT using DenseNet with log files
    Huang, Ying
    Cai, Ruxin
    Pi, Yifei
    Ma, Kui
    Kong, Qing
    Zhuo, Weihai
    Kong, Yan
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2024, 32 (04) : 1199 - 1208
  • [25] 3D structure recovery and errors on the intrinsic parameters
    Boufama, BS
    1998 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN, AND CYBERNETICS, VOLS 1-5, 1998, : 4441 - 4446
  • [26] 3D dose reconstruction for clinical evaluation of IMRT pretreatment verification with an EPID
    van Zijtveld, Mathilda
    Dirkx, Maarten L. P.
    de Boer, Hans C. J.
    Heijmen, Ben J. M.
    RADIOTHERAPY AND ONCOLOGY, 2007, 82 (02) : 201 - 207
  • [27] A Novel EPID-Based 3D Dose Reconstruction for IMRT QA
    Alhazmi, A.
    Gianoli, C.
    Neppl, S.
    Veloza, S.
    Martins, J.
    Podesta, M.
    Verhaegen, F.
    Reiner, M.
    Belka, C.
    Parodi, K.
    MEDICAL PHYSICS, 2017, 44 (06) : 2887 - 2887
  • [28] A Method of 3D Dose Reconstruction Using MapCHECK Measurement for IMRT QA
    Kim, S.
    Barnett, E.
    Gallamore, M.
    Yeung, I.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [29] 3D "IN VIVO" DOSE VERIFICATION OF IMRT TREATMENTS USING A TRANSMISSION DETECTOR
    Ostinelli, A.
    Monti, A. F.
    Gelosa, S.
    Berlusconi, C.
    Scandolaro, L.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S229 - S230
  • [30] Pre-treatment QA for IMRT: comparison of planar and helical diode arrays and 3D patient dose reconstruction
    Hindmarsh, J.
    David, R.
    Zwan, B.
    Sloan, K.
    Lee, C.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S446 - S447