A feasibility study to predict 3D dose delivery accuracy for IMRT using DenseNet with log files

被引:0
|
作者
Huang, Ying [1 ,2 ,3 ]
Cai, Ruxin [3 ]
Pi, Yifei [4 ]
Ma, Kui [5 ]
Kong, Qing [1 ]
Zhuo, Weihai [2 ]
Kong, Yan [6 ]
机构
[1] Fudan Univ, Inst Modern Phys, Shanghai, Peoples R China
[2] Fudan Univ, Inst Radiat Med, Shanghai 200032, Peoples R China
[3] Shanghai Jiao Tong Univ, Shanghai Chest Hosp, Sch Med, Shanghai, Peoples R China
[4] hengzhou Univ, Affiliated Hosp 1, Dept Radiat Oncol, Zhengzhou, Henan, Peoples R China
[5] Varian Med Syst, Beijing, Peoples R China
[6] Jiangnan Univ, Dept Radiat Oncol, Affiliated Hosp, Wuxi 214122, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
Three-dimensional gamma prediction; log files; patient-specific quality assurance; MLC POSITIONAL ERRORS; CLINICAL IMPLEMENTATION; QUALITY-ASSURANCE; SLIDING WINDOW; RADIOTHERAPY; VERIFICATION; EXPERIENCE;
D O I
10.3233/XST-230412
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
OBJECTIVE: This study aims to explore the feasibility of DenseNet in the establishment of a three-dimensional (3D) gamma prediction model of IMRT based on the actual parameters recorded in the log files during delivery. METHODS: A total of 55 IMRT plans (including 367 fields) were randomly selected. The gamma analysis was performed using gamma criteria of 3% /3 mm (Dose Difference/Distance to Agreement), 3% /2 mm, 2% /3 mm, and 2% /2 mm with a 10% dose threshold. In addition, the log files that recorded the gantry angle, monitor units (MU), multi-leaf collimator (MLC), and jaws position during delivery were collected. These log files were then converted to MU-weighted fluence maps as the input of DenseNet, gamma passing rates (GPRs) under four different gamma criteria as the output, and mean square errors (MSEs) as the loss function of this model. RESULTS: Under different gamma criteria, the accuracy of a 3D GPR prediction model decreased with the implementation of stricter gamma criteria. In the test set, the mean absolute error (MAE) of the prediction model under the gamma criteria of 3% /3 mm, 2% /3 mm, 3% /2 mm, and 2% /2 mm was 1.41, 1.44, 3.29, and 3.54, respectively; the root mean square error (RMSE) was 1.91, 1.85, 4.27, and 4.40, respectively; the Sr was 0.487, 0.554, 0.573, and 0.506, respectively. There was a correlation between predicted and measured GPRs (P < 0.01). Additionally, there was no significant difference in the accuracy between the validation set and the test set. The accuracy in the high GPR group was high, and the MAE in the high GPR group was smaller than that in the low GPR group under four different gamma criteria. CONCLUSIONS: In this study, a 3D GPR prediction model of patient-specific QA using DenseNet was established based on log files. As an auxiliary tool for 3D dose verification in IMRT, this model is expected to improve the accuracy and efficiency of dose validation.
引用
收藏
页码:1199 / 1208
页数:10
相关论文
共 50 条
  • [1] Comparison of 3D Dose Delivery Accuracy and Efficiency for VMAT Between 2 Linear Accelerators Using Linac Log Files
    Wijesooriya, K.
    Desai, V.
    Read, P. W.
    Larner, J. M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S722 - S722
  • [2] Using Trajectory Log Files to Evaluate Dose Delivery Accuracy for SBRT and Hyperarc
    Volk, A.
    Misa, J.
    Thayer-Freeman, C.
    Luo, W.
    MEDICAL PHYSICS, 2024, 51 (10) : 7899 - 7899
  • [3] Using MLC Log Files for Daily IMRT Delivery Verification
    Stathakis, S.
    Defoor, D.
    Linden, P.
    Kirby, N.
    Papanikolaou, N.
    MEDICAL PHYSICS, 2015, 42 (06) : 3517 - 3518
  • [4] Development of Error Estimating Program for IMRT Dose Delivery Using Dynamic MLC Log Files
    Kawakami, M.
    Sato, S.
    Miyabe, Y.
    Tanabe, K.
    Nishimura, M.
    Tsuji, M.
    Murakami, Y.
    Kawabata, H.
    Fushiki, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S866 - S867
  • [5] Monte Carlo dose calculation of segmental IMRT delivery to a moving phantom using dynamic MLC and gating log files
    Oliver, Mike
    Staruch, Robert
    Gladwish, Adam
    Craig, Jeff
    Chen, Jeff
    Wong, Eugene
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (10): : N187 - N196
  • [6] Rapid Arc Patient Specific Dose Delivery Accuracy under Extreme Mechanical Limits Using Linac Log Files
    Wijesooriya, K.
    Benedict, S.
    Read, P.
    Rich, T.
    Larner, J.
    MEDICAL PHYSICS, 2010, 37 (06) : 3401 - +
  • [7] Monte Carlo based IMRT dose verification using MLC log files and R/V outputs
    Luo, Wei
    Li, Jinsheng
    Price, Robert A., Jr.
    Chen, Lili
    Yang, Jie
    Fan, Jiajin
    Chen, Zuoqun
    McNeeley, Shawn
    Xu, Xiu
    Ma, Chang-Ming
    MEDICAL PHYSICS, 2006, 33 (07) : 2557 - 2564
  • [8] The Effects of Low Dose Regions On 3D IMRT QA Delivery Using a MatriXX 2D Array and MULTICUBE
    Fox, C.
    Sanford, R.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [9] 4D dose calculation using 3D elastic dose registration in lung IMRT
    Wu, J.
    Nazareth, D.
    Castro-Pareja, C.
    Lei, P.
    Shekhar, R.
    D'Souza, W.
    MEDICAL PHYSICS, 2006, 33 (06) : 2244 - 2244
  • [10] Dosimetric verification of IMRT and 3D conformal treatment delivery using EPID
    Nasseri, S.
    Bahreyni, M. H.
    Momennezhad, M.
    Gholamhosseinian, H.
    Shahedi, F.
    Hashemi, S. M.
    Mohammadi, M.
    APPLIED RADIATION AND ISOTOPES, 2022, 182