摘要
Background: Quantitative shear wave elastography (SWE) has been developed and utilized to aid in the differentiation between benign and malignant breast lesions based on their stiffness. Objectives: The purpose of this study was to evaluate the clinical effects of the additional use of SWE to conventional ultrasound (US) according to the maximum (Emax) and mean (Emean) elasticitiy values. Patients and Methods: A total 115 patients with 133 lesions were assessed using conventional US and SWE. All patients underwent US-guided core needle biopsy or surgery, and the pathological results were used as reference standards. We compared the diagnostic values including sensitivities, specificities, positive predictive values (PPVs) and negative predictive values (NPVs) and accuracies of conventional US and SWE according to the E-max and E-mean values. Next, we obtained the optimal E-max and E-mean cutoff values for SWE. Using these cutoff values, we analyzed the clinical effects of the additional use of SWE to conventional US based on the corrected results. Results: Of the 133 breast lesions, 32 were malignant and 101 were benign. In the differentiation of benign and malignant lesions, conventional US resulted in sensitivity of 100 %, specificity of 43.0 %, PPV of 57.1 %, NPV of 36.7 %, and accuracy of 100 %. Regarding SWE, the sensitivity, specificity, PPV, NPV, and accuracy values based on E-max were 84.4 %, 89.1 %, 71.1 %, 94.7 %, and 88.0 %, respectively, and the corresponding values based on E-mean were 84.8 %, 93.0 %, 91.0 %, 80.0 %, and 94.9 %, respectively. The optimal E-max and E-mean cutoff values were 81.3 and 60.7 kPa, respectively. However, there was no significant difference between E-max and E-mean. The corrected results related to the additional use of SWE to conventional US indicated 97.0 % sensitivity, 93.0 % specificity, 82.1 % PPV, 98.9 % NPV, and 94.0 % accuracy (P < 0.0001). Conclusion: The additional use of SWE to conventional US resulted in marked improvements in specificity, PPV, and accuracy and slight diminutions in sensitivity and NPV for the differentiation benign and malignant breast lesions. Both E-max and E-mean were effective diagnostic parameters, and there was no significant difference between these two parameters.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Application of Shear Wave Elastography to Evaluate the Stiffness of Normal Testes and Inflammatory Epididymal Tail Masses
    Chen, Fei
    Mao, Lin
    Zhou, Xiaohua
    Qiao, Xueyan
    Luo, Yanhua
    Zhu, Zhimin
    Chen, Rui
    Qiu, Shaodong
    Zeng, Bidan
    ULTRASOUND QUARTERLY, 2021, 37 (02) : 161 - 167
  • [32] Shear Wave Imaging of Breast Tissue by Color Doppler Shear Wave Elastography
    Yamakoshi, Yoshiki
    Nakajima, Takahito
    Kasahara, Toshihiro
    Yamazaki, Mayuko
    Koda, Ren
    Sunaguchi, Naoki
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2017, 64 (02) : 340 - 348
  • [33] Added Value of Shear-Wave Elastography for Evaluation of Breast Masses Detected with Screening US Imaging
    Lee, Su Hyun
    Chang, Jung Min
    Kim, Won Hwa
    Bae, Min Sun
    Seo, Mirinae
    Koo, Hye Ryoung
    Chu, A. Jung
    Gweon, Hye Mi
    Cho, Nariya
    Moon, Woo Kyung
    RADIOLOGY, 2014, 273 (01) : 61 - 69
  • [34] Stiffness in breast masses with posterior acoustic shadowing: significance of ultrasound real time shear wave elastography
    Hui Luo
    Jian Li
    Yang Shi
    Xiaojun Xiao
    Yuanyang Wang
    Zhanghong Wei
    Jinfeng Xu
    BMC Medical Imaging, 22
  • [35] Diagnostic performances of shear wave elastography: which parameter to use in differential diagnosis of solid breast masses?
    Lee, Eun Jung
    Jung, Hae Kyoung
    Ko, Kyung Hee
    Lee, Jong Tae
    Yoon, Jung Hyun
    EUROPEAN RADIOLOGY, 2013, 23 (07) : 1803 - 1811
  • [36] Stiffness in breast masses with posterior acoustic shadowing: significance of ultrasound real time shear wave elastography
    Luo, Hui
    Li, Jian
    Shi, Yang
    Xiao, Xiaojun
    Wang, Yuanyang
    Wei, Zhanghong
    Xu, Jinfeng
    BMC MEDICAL IMAGING, 2022, 22 (01)
  • [37] Diagnostic performances of shear wave elastography: which parameter to use in differential diagnosis of solid breast masses?
    Eun Jung Lee
    Hae Kyoung Jung
    Kyung Hee Ko
    Jong Tae Lee
    Jung Hyun Yoon
    European Radiology, 2013, 23 : 1803 - 1811
  • [38] Differentiating solid breast masses: comparison of the diagnostic efficacy of shear wave elastography and magnetic resonance imaging
    Farghadani, Maryam
    Barikbin, Rozbeh
    Rezaei, Mostafa Haji
    Hekmatnia, Ali
    Aalinezhad, Marzieh
    Zare, Hosein
    DIAGNOSIS, 2021, 8 (03) : 382 - 387
  • [39] Diagnostic values of shear wave elastography and strain elastography for breast lesions
    Jiang, Huiwen
    Yu, Xiaodan
    Zhang, Lina
    Song, Linxiao
    Gao, Xiuhua
    REVISTA MEDICA DE CHILE, 2020, 148 (09) : 1239 - 1245
  • [40] Usability of Transthoracic Shear Wave Elastography in Differentiation of Subpleural Solid Masses
    Ozgokce, Mesut
    Yavuz, Alpaslan
    Akbudak, Ibrahim
    Durmaz, Fatma
    Uney, Ibrahim
    Aydin, Yener
    Yildiz, Hanifi
    Batur, Abdussamet
    Arslan, Harun
    Dundar, Ilyas
    ULTRASOUND QUARTERLY, 2018, 34 (04) : 233 - 237