Balanced SSFP Dixon imaging with banding-artifact reduction at 3 Tesla

被引:10
|
作者
Quist, Brady [1 ,2 ]
Hargreaves, Brian A. [1 ]
Daniel, Bruce L. [1 ]
Saranathan, Manojkumar [1 ]
机构
[1] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Elect Engn, Stanford, CA 94305 USA
关键词
bSSFP; SSFP; fat suppression; steady-state; fat water separation; artifact reduction; STATE FREE PRECESSION; FAT-WATER SEPARATION; STEADY-STATE; MUSCULOSKELETAL MRI; MAGNETIC-RESONANCE; RELAXATION-TIMES; IN-VIVO; 3.0; T; PHASE; ACQUISITION;
D O I
10.1002/mrm.25449
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo develop a three-dimensional (3D) balanced steady-state free-precession (bSSFP) two-point Dixon method with banding-artifact suppression to offer robust high-resolution 3D bright-fluid imaging. MethodsA complex sum reconstruction that combines phase-cycled bSSFP images acquired at specific echo times for robust fat/water separation without banding was investigated and compared with a magnitude-based method. Bloch simulations using both single-peak and multiple-peak fat models were performed to predict the performance of these methods for a wide range of echo times and repetition times. The quality and degree of fat/water separation was evaluated in both simulations and using in vivo imaging. ResultsSimulations predicted that both effective banding-artifact suppression and substantial improvements in fat/water separation are possible at echo times that are different from conventional echo times, enabling improved spatial resolution. Comparisons between various echo times and repetition times in vivo validated the improved fat/water separation and effective banding-artifact removal predicted by the simulations. ConclusionThe proposed complex sum Dixon 3D bSSFP method is able to effectively separate fat and water at different sets of echo times, while removing banding-artifacts, providing a fast, high-resolution, T-2-like sequence without blurring. Magn Reson Med 74:706-715, 2015. (c) 2014 Wiley Periodicals, Inc.
引用
收藏
页码:706 / 715
页数:10
相关论文
共 50 条
  • [21] Assessment of aortic diameter in Marfan patients: intraindividual comparison of 3D-Dixon and 2D-SSFP magnetic resonance imaging
    Felicia Wright
    Malte Warncke
    Martin Sinn
    Inka Ristow
    Alexander Lenz
    Christoph Riedel
    Bjoern P. Schoennagel
    Shuo Zhang
    Michael G. Kaul
    Gerhard Adam
    Yskert von Kodolitsch
    Susanne Sehner
    Peter Bannas
    European Radiology, 2023, 33 : 1687 - 1697
  • [22] Free-Breathing Variable Flip Angle Balanced SSFP Cardiac Cine Imaging with Reduced SAR at 3T
    Srinivasan, Subashini
    Kroeker, Randall M.
    Gabriel, Simon
    Plotnik, Adam
    Godinez, Sergio R.
    Hu, Peng
    Halnon, Nancy
    Finn, J. Paul
    Ennis, Daniel B.
    MAGNETIC RESONANCE IN MEDICINE, 2016, 76 (04) : 1210 - 1216
  • [23] 1119 Direct comparison of the signal-to-noise ratio for 3D and 2D balanced SSFP cine imaging
    Dana C Peters
    Daniel A Herzka
    Reza Nezafat
    Warren J Manning
    Journal of Cardiovascular Magnetic Resonance, 10 (Suppl 1)
  • [24] Fast 3D 1H spectroscopic imaging at 3 tesla using spectroscopic missing-pulse SSFP with 3D spatial preselection
    Schuster, Christian
    Dreher, Wolfgang
    Geppert, Christian
    Leibfritz, Dieter
    MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (01) : 82 - 89
  • [25] A 3D balanced-SSFP Dixon technique with group-encoded k-space segmentation for breath-held non-contrast-enhanced MR angiography
    Saranathan, Manojkumar
    Bayram, Ersin
    Worters, Pauline W.
    Glockner, James F.
    MAGNETIC RESONANCE IMAGING, 2012, 30 (02) : 158 - 164
  • [26] 7 Tesla (T) human cardiovascular magnetic resonance imaging using FLASH and SSFP to assess cardiac function: validation against 1.5 T and 3 T.
    Suttie, J. J.
    DelaBarre, L.
    Pitcher, A.
    van de Moortele, P. F.
    Dass, S.
    Snyder, C. J.
    Francis, J. M.
    Metzger, G. J.
    Weale, P.
    Ugurbil, K.
    Neubauer, S.
    Robson, M.
    Vaughan, T.
    NMR IN BIOMEDICINE, 2012, 25 (01) : 27 - 34
  • [27] Fast isotropic banding-free bSSFP imaging using 3D dynamically phase-cycled radial bSSFP (3D DYPR-SSFP)
    Benkert, Thomas
    Ehses, Philipp
    Blaimer, Martin
    Jakob, Peter M.
    Breuer, Felix A.
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2016, 26 (01): : 63 - 74
  • [28] Water Selective Imaging and bSSFP Banding Artifact Correction in Humans and Small Animals at 3T and 7T, Respectively
    Ribot, Emeline J.
    Wecker, Didier
    Trotier, Aurelien J.
    Dallaudiere, Benjamin
    Lefrancois, William
    Thiaudiere, Eric
    Franconi, Jean-Michel
    Miraux, Sylvain
    PLOS ONE, 2015, 10 (10):
  • [29] Cardiac Cine MR imaging: Fast high-resolution ventricular coverage using TGRAPPA cine SSFP for assessment of systolic and diastolic LV function at 3 Tesla
    Bernd J Wintersperger
    Daniel Theisen
    Torleif A Sandner
    Kerstin Bauner
    Maximilian F Reiser
    Konstantin Nikolaou
    Journal of Cardiovascular Magnetic Resonance, 12 (Suppl 1)
  • [30] Investigation of Parallel Radiofrequency Transmission for the Reduction of Heating in Long Conductive Leads in 3 Tesla Magnetic Resonance Imaging
    McElcheran, Clare E.
    Yang, Benson
    Anderson, Kevan J. T.
    Golenstani-Rad, Laleh
    Graham, Simon J.
    PLOS ONE, 2015, 10 (08):