AAPM TG-43 formalism for brachytherapy dose calculation of a 137Cs tube source

被引:3
|
作者
Zhang, PP [1 ]
Beddar, AS
Sibata, CH
机构
[1] Columbia Univ, Dept Radiat Oncol, New York, NY 10032 USA
[2] Univ Texas, MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[3] E Carolina Univ, Dept Radiat Oncol, Greenville, NC 27858 USA
关键词
dosimetry; brachytherapy; TG-43; formalism; Monte Carlo calculations; 137Cs;
D O I
10.1118/1.1650564
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We present a development of the use of the AAPM TG-43 dose formalism applied to Cs-137 gynecological implant sources. The geometry factor, radial dose function, and anisotropy function of a Cs-137 source modeled after the Nuclear Associates 67-809 series stainless steel jacketed tube source were derived following the AAPM TG-43 formalism. The dose rate distribution through the center of the source using the AAPM TG-43 dose formalism is calculated and compared with the calculations obtained using the Sievert summation and Monte Carlo simulation. The three methods resulted in an agreement within less than 5%, or an isodose rate line agreement within 2 mm. We demonstrate that the AAPM TG-43 formalism can be applied to Cs-137 linear sources and is capable of serving as a Cs-137 dose calculation algorithm that can be used for treatment planning purpose. (C) 2004 American Association of Physicists in Medicine.
引用
收藏
页码:755 / 759
页数:5
相关论文
共 50 条
  • [41] Developing a Treatment Planning Software Based on TG-43U1 Formalism for Cs-137 LDR Brachytherapy
    Sina, Sedigheh
    Faghihi, Reza
    Meigooni, Ali Soleimani
    Siavashpour, Zahra
    Mosleh-Shirazi, Mohammad Amin
    IRANIAN RED CRESCENT MEDICAL JOURNAL, 2013, 15 (08) : 712 - 717
  • [42] The TG-43 dosimetric characteristics of the IsoAid ADVANTAGE I-125 brachytherapy source
    Hayes, JL
    Zhang, H
    Miller, J
    Sowards, K
    Meigooni, A
    MEDICAL PHYSICS, 2002, 29 (06) : 1220 - 1220
  • [43] Determination of task group 43 dosimetric parameters for CSM40 137Cs source for use in brachytherapy
    Firoozabadi M.M.
    Jimabadi E.
    Ghorbani M.
    Behmadi M.
    Radiological Physics and Technology, 2018, 11 (1) : 82 - 90
  • [44] Comparison of TG-43 and TG-186 in breast irradiation using a low energy electronic brachytherapy source
    White, Shane A.
    Landry, Guillaume
    Fonseca, Gabriel Paiva
    Holt, Randy
    Rusch, Thomas
    Beaulieu, Luc
    Verhaegen, Frank
    Reniers, Brigitte
    MEDICAL PHYSICS, 2014, 41 (06)
  • [45] Technical Note: Monte Carlo calculations of the AAPM TG-43 brachytherapy dosimetry parameters for a new titanium-encapsulated Yb-169 source
    Reynoso, Francisco J.
    Munro, John J., III
    Cho, Sang Hyun
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2017, 18 (04): : 193 - 199
  • [46] Monte Carlo Determination of Dosimetric Parameters of a New 125I Brachytherapy Source According to AAPM TG-43 (U1) Protocol
    Baghani, Hamid Reza
    Lohrabian, Vahid
    Aghamiri, Mahmoud Reza
    Robatjazi, Mostafa
    ARCHIVES OF IRANIAN MEDICINE, 2016, 19 (03) : 186 - 191
  • [47] Evaluating AAPM TG-43 In-Water HDR 192Ir Brachytherapy Reference Dosimetry: A Comparison Study
    Sarfehnia, A.
    Kawrakow, I.
    Seuntjens, J.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [48] Experimental Determination of Modified TG-43 Dosimetry Parameters for the Xoft Axxent® Electronic Brachytherapy Source
    Simiele, S.
    Palmer, B.
    DeWerd, L.
    MEDICAL PHYSICS, 2016, 43 (06) : 3625 - 3625
  • [49] Monte Carlo calculation of the TG-43 dosimetry parameters for the INTRABEAM source with spherical applicators
    Alvarez, David Santiago Ayala
    Watson, Peter G. F.
    Popovic, Marija
    Heng, Veng Jean
    Evans, Michael D. C.
    Seuntjens, Jan
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (21):
  • [50] Improvement of LDR Brachytherapy TG-43 Dose Calculations with a GPU-Accelerated Raytracing Algorithm
    Bourque, A.
    Ganiepy, J.
    Mathieu, D.
    Hissoiny, S.
    Beaulieu, L.
    Despres, P.
    MEDICAL PHYSICS, 2011, 38 (06)