Study on CO2 absorption performance of lab-scale ceramic hollow fiber membrane contactor by gas/liquid flow direction and module design

被引:56
|
作者
Lee, Hong Joo [1 ]
Park, Yu Gang [1 ]
Kim, Min Kwang [1 ]
Lee, Seung Hwan [1 ]
Park, Jung Hoon [1 ]
机构
[1] Dongguk Univ, Wonheung Gwan F619,30 Pildong Ro 1gil, Seoul 100715, South Korea
关键词
Membrane contactor; Ceramic hollow fiber membrane; Membrane contactor module; Module design; Scale-up; CARBON-DIOXIDE; GAS-ABSORPTION; CAPTURE; MORPHOLOGY; SOLVENTS; REMOVAL;
D O I
10.1016/j.seppur.2019.03.011
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Membrane contactor has been actively studied in recent years, but it is difficult to modulate the ceramic hollow fiber membranes because they are extremely brittle and poor in flexibility. For this reason, research on ceramic hollow fiber membrane contactor modules has been rarely carried out. In this study, hydrophobic modified ceramic hollow fiber membranes were fabricated by phase inversion method. 1-in. unit module, a 3-parallel connection module, and a 2.5-in. advanced module with the ceramic hollow fiber membranes were developed. A membrane contactor CO2 capture system with the module was set up and characteristics of ceramic hollow fiber membrane contactor were analyzed. The highest CO2 absorption property was observed in the configuration in which the liquid flows on the shell side from the bottom to the top, and the gas and the liquid contacts in the counter-current. In addition, a lab-scale ceramic hollow fiber membrane contactor unit module was successfully developed to treat 0.175 Nm(3)/h flue gas with 90% CO2 removal efficiency. To the best of my knowledge, this is the first case of CO2 absorption experiment using hydrophobic ceramic hollow fiber membrane contactor module instead of the polymeric membrane module or single ceramic membrane. These results are expected to be very valuable as fundamental and important data for scale-up of ceramic membrane contactor process.
引用
收藏
页码:189 / 196
页数:8
相关论文
共 50 条
  • [11] Simulation of CO2 absorption into aqueous DEA using a hollow fiber membrane contactor: Evaluation of contactor performance
    Delgado, José A.
    Uguina, María A.
    Sotelo, José L.
    Águeda, Vicente I.
    Sanz, Abel
    Chemical Engineering Journal, 2009, 152 (2-3): : 396 - 405
  • [12] Simulation of CO2 absorption into aqueous DEA using a hollow fiber membrane contactor: Evaluation of contactor performance
    Delgado, Jose A.
    Uguina, Maria A.
    Sotelo, Jose L.
    Agueda, Vicente I.
    Sanz, Abel
    CHEMICAL ENGINEERING JOURNAL, 2009, 152 (2-3) : 396 - 405
  • [13] Effect of Feed Gas Flow Rate on CO2 Absorption through Super Hydrophobic Hollow Fiber membrane Contactor
    Kartohardjono, Sutrasno
    Alexander, Kevin
    Larasati, Annisa
    Sihombing, Ivander Christian
    QUALITY IN RESEARCH: INTERNATIONAL SYMPOSIUM ON MATERIALS, METALLURGY, AND CHEMICAL ENGINEERING, 2018, 316
  • [14] Mathematical modeling and cascade design of hollow fiber membrane contactor for CO2 absorption by monoethanolamine
    Boributh, Somnuk
    Rongwong, Wichitpan
    Assabumrungrat, Suttichai
    Laosiripojana, Navadol
    Jiraratananon, Ratana
    JOURNAL OF MEMBRANE SCIENCE, 2012, 401 : 175 - 189
  • [15] Effect of fiber packing density on physical CO2 absorption performance in gas-liquid membrane contactor
    Naim, R.
    Ismail, A. F.
    SEPARATION AND PURIFICATION TECHNOLOGY, 2013, 115 : 152 - 157
  • [16] Experimental studies on CO2 absorption in immersed hollow fiber membrane contactor
    Wu, Xiaona
    Wang, Liang
    Zhang, Zhaohui
    Li, Wenyang
    Guo, Xingfei
    SUSTAINABLE CITIES DEVELOPMENT AND ENVIRONMENT, PTS 1-3, 2012, 209-211 : 1571 - 1575
  • [17] CO2 absorption at elevated pressures using a hollow fiber membrane contactor
    Dindore, VY
    Brilman, DWF
    Feron, PHM
    Versteeg, GF
    JOURNAL OF MEMBRANE SCIENCE, 2004, 235 (1-2) : 99 - 109
  • [18] Development of asymmetric polysulfone hollow fiber membrane contactor for CO2 absorption
    Rahbari-Sisakht, M.
    Ismail, A. F.
    Matsuura, T.
    SEPARATION AND PURIFICATION TECHNOLOGY, 2012, 86 : 215 - 220
  • [19] An analytical study of laminar concurrent flow membrane absorption through a hollow fiber gas-liquid membrane contactor
    Ho, Chii-Dong
    Sung, Yun-Jen
    Chuang, Yu-Chuan
    JOURNAL OF MEMBRANE SCIENCE, 2013, 428 : 232 - 240
  • [20] Experimental study of CO2 absorption/stripping via PVDF hollow fiber membrane contactor
    Mansourizadeh, Amir
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2012, 90 (04): : 555 - 562