Effect of fiber packing density on physical CO2 absorption performance in gas-liquid membrane contactor

被引:22
|
作者
Naim, R. [1 ,2 ,3 ]
Ismail, A. F. [1 ,2 ]
机构
[1] Univ Teknol Malaysia, Adv Membrane Technol Res Ctr, Skudai 81310, Johor, Malaysia
[2] Univ Teknol Malaysia, Fac Petr & Renewable Energy Engn, Dept Gas Engn, Skudai 81310, Johor, Malaysia
[3] Univ Malaysia Pahang, Fac Chem Engn & Nat Resources, Kuantan 26300, Pahang, Malaysia
关键词
PVDF; Packing density; CO2; absorption; Membrane contactor; MASS-TRANSFER; POLYVINYLIDENE FLUORIDE; FLOW DISTRIBUTION; HOLLOW FIBERS; MODULES; COEFFICIENTS; EXTRACTION;
D O I
10.1016/j.seppur.2013.04.045
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Microporous polyvinylidene fluoride (PVDF) hollow fiber membranes were fabricated via wet-spinning process. The prepared fibers were characterized in terms of gas permeation, wetting pressure and membrane morphology. Physical absorption of CO2 from distilled water was conducted through the gas-liquid membrane contactors. The overall mass transfer resistance of the membrane system was evaluated using Wilson plot analysis. The spun membranes have good gas permeability, high wetting pressure and reasonably effective surface porosity which is appropriate for mass transfer between gas and liquid phases. It was found that by increasing the packing density of the membrane module, CO2 absorption flux decreases with reductions in liquid velocity. At increasing packing densities of up to 13%, liquid side resistance contributed to more than 90% of the overall mass transfer resistance due to 'dead zone' phenomena. The overall mass transfer coefficient of the module increased as the packing density increased from 2.6% to 13%. A clear trend of mass transfer resistance can be observed when the fiber packing density was varied accordingly in gas-liquid membrane contactor systems. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:152 / 157
页数:6
相关论文
共 50 条
  • [1] Effect of PVDF concentration on the morphology and performance of hollow fiber membrane employed as gas-liquid membrane contactor for CO2 absorption
    Ghasem, Nayef
    Al-Marzouqi, Mohamed
    Duidar, Ali
    SEPARATION AND PURIFICATION TECHNOLOGY, 2012, 98 : 174 - 185
  • [2] PVDF/CaCO3 composite hollow fiber membrane for CO2 absorption in gas-liquid membrane contactor
    Fosi-Kofal, M.
    Mustafa, A.
    Ismail, A. F.
    Rezaei-DashtArzhandi, M.
    Matsuura, T.
    JOURNAL OF NATURAL GAS SCIENCE AND ENGINEERING, 2016, 31 : 428 - 436
  • [3] Study of an innovative gas-liquid contactor for CO2 absorption
    Chabanon, E.
    Bouallou, C.
    Remigy, J. C.
    Lasseuguette, E.
    Medina, Y.
    Favre, E.
    Nguyen, P. T.
    Roizard, D.
    10TH INTERNATIONAL CONFERENCE ON GREENHOUSE GAS CONTROL TECHNOLOGIES, 2011, 4 : 1769 - 1776
  • [4] Surface modification of polypropylene hollow fiber membranes using fluorosilane for CO2 absorption in a gas-liquid membrane contactor
    Kim, Kwanghwi
    Lee, Heejun
    Park, Hyun Sic
    Song, Hojun
    Kim, Suhan
    HELIYON, 2023, 9 (09)
  • [5] CO2 REMOVAL BY HOLLOW-FIBER GAS-LIQUID CONTACTOR
    NISHIKAWA, N
    ISHIBASHI, M
    OHTA, H
    AKUTSU, N
    MATSUMOTO, H
    KAMATA, T
    KITAMURA, H
    ENERGY CONVERSION AND MANAGEMENT, 1995, 36 (6-9) : 415 - 418
  • [6] Effect of polymer extrusion temperature on poly(vinylidene fluoride) hollow fiber membranes: Properties and performance used as gas-liquid membrane contactor for CO2 absorption
    Ghasem, Nayef
    Al-Marzouqi, Mohamed
    Rahim, Nihmiya Abdul
    SEPARATION AND PURIFICATION TECHNOLOGY, 2012, 99 : 91 - 103
  • [7] Rotating liquid sheet contactor: A new gas-liquid contactor system in CO2 absorption by nanofluids
    Mehdipour, Morteza
    Keshavarz, Peyman
    Rahimpour, Mohammad Reza
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2021, 165
  • [8] Absorption of CO2 Form Natural Gas via Gas-liquid PVDF Hollow Fiber Membrane Contactor and Potassium Glycinate as Solvent
    Ghasem, Nayef
    Al-Marzouqi, Mohamed
    Rahim, Nihmiya Abdul
    JURNAL TEKNOLOGI, 2014, 69 (09):
  • [9] Performance improvement of countercurrent-flow membrane gas absorption in a hollow fiber gas-liquid membrane contactor
    Ho, Chii-Dong
    Sung, Yun-Jen
    Chen, Wei-Ting
    Tsai, Feng-Chi
    MEMBRANE WATER TREATMENT, 2017, 8 (01) : 35 - 50
  • [10] Hollow fiber membrane contactor as a gas-liquid model contactor
    Dindore, VY
    Brilman, DWF
    Versteeg, GE
    CHEMICAL ENGINEERING SCIENCE, 2005, 60 (02) : 467 - 479