Effect of fiber packing density on physical CO2 absorption performance in gas-liquid membrane contactor

被引:22
|
作者
Naim, R. [1 ,2 ,3 ]
Ismail, A. F. [1 ,2 ]
机构
[1] Univ Teknol Malaysia, Adv Membrane Technol Res Ctr, Skudai 81310, Johor, Malaysia
[2] Univ Teknol Malaysia, Fac Petr & Renewable Energy Engn, Dept Gas Engn, Skudai 81310, Johor, Malaysia
[3] Univ Malaysia Pahang, Fac Chem Engn & Nat Resources, Kuantan 26300, Pahang, Malaysia
关键词
PVDF; Packing density; CO2; absorption; Membrane contactor; MASS-TRANSFER; POLYVINYLIDENE FLUORIDE; FLOW DISTRIBUTION; HOLLOW FIBERS; MODULES; COEFFICIENTS; EXTRACTION;
D O I
10.1016/j.seppur.2013.04.045
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Microporous polyvinylidene fluoride (PVDF) hollow fiber membranes were fabricated via wet-spinning process. The prepared fibers were characterized in terms of gas permeation, wetting pressure and membrane morphology. Physical absorption of CO2 from distilled water was conducted through the gas-liquid membrane contactors. The overall mass transfer resistance of the membrane system was evaluated using Wilson plot analysis. The spun membranes have good gas permeability, high wetting pressure and reasonably effective surface porosity which is appropriate for mass transfer between gas and liquid phases. It was found that by increasing the packing density of the membrane module, CO2 absorption flux decreases with reductions in liquid velocity. At increasing packing densities of up to 13%, liquid side resistance contributed to more than 90% of the overall mass transfer resistance due to 'dead zone' phenomena. The overall mass transfer coefficient of the module increased as the packing density increased from 2.6% to 13%. A clear trend of mass transfer resistance can be observed when the fiber packing density was varied accordingly in gas-liquid membrane contactor systems. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:152 / 157
页数:6
相关论文
共 50 条
  • [31] Experimental Study of CO2 Absorption in a Hollow Fiber Membrane Contactor
    Kallas, Therese
    Chabanon, Elodie
    Germain, Guillaume
    Bouallou, Chakib
    PRES'09: 12TH INTERNATIONAL CONFERENCE ON PROCESS INTEGRATION, MODELLING AND OPTIMISATION FOR ENERGY SAVING AND POLLUTION REDUCTION, PTS 1 AND 2, 2009, 18 : 267 - 272
  • [32] An analytical study of laminar concurrent flow membrane absorption through a hollow fiber gas-liquid membrane contactor
    Ho, Chii-Dong
    Sung, Yun-Jen
    Chuang, Yu-Chuan
    JOURNAL OF MEMBRANE SCIENCE, 2013, 428 : 232 - 240
  • [33] Effect of Feed Gas Flow Rate on CO2 Absorption through Super Hydrophobic Hollow Fiber membrane Contactor
    Kartohardjono, Sutrasno
    Alexander, Kevin
    Larasati, Annisa
    Sihombing, Ivander Christian
    QUALITY IN RESEARCH: INTERNATIONAL SYMPOSIUM ON MATERIALS, METALLURGY, AND CHEMICAL ENGINEERING, 2018, 316
  • [34] Preparation of nanoparticles with a continuous gas-liquid membrane contactor: Absorption process
    Jia, Zhiqian
    Chang, Qing
    Qin, Jin
    Sun, Huijie
    JOURNAL OF MEMBRANE SCIENCE, 2010, 352 (1-2) : 50 - 54
  • [35] Study on CO2 absorption performance of lab-scale ceramic hollow fiber membrane contactor by gas/liquid flow direction and module design
    Lee, Hong Joo
    Park, Yu Gang
    Kim, Min Kwang
    Lee, Seung Hwan
    Park, Jung Hoon
    SEPARATION AND PURIFICATION TECHNOLOGY, 2019, 220 : 189 - 196
  • [36] An electrolytic bubble column with an external hollow fiber membrane gas-liquid contactor for effective microbial electrosynthesis of acetate from CO2
    Cui, Kai
    Guo, Kun
    Carvajal-Arroyo, Jose M.
    Arends, Jan
    Rabaey, Korneel
    CHEMICAL ENGINEERING JOURNAL, 2023, 471
  • [37] Experimental and theoretical analyses of effects of membrane properties on CO2 absorption performance of a hollow fiber membrane contactor
    Takahashi, Nobuhide
    Mano, Hiroshi
    Okabe, Kazuhiro
    Nakamura, Miho
    Fujioka, Yuichi
    Mimura, Tomio
    Yagi, Yasuyuki
    KAGAKU KOGAKU RONBUNSHU, 2008, 34 (01) : 76 - 84
  • [38] Gas-liquid membrane contactors for CO2 removal
    Simons, Katja
    Nijmeijer, Kitty
    Wessling, Matthias
    JOURNAL OF MEMBRANE SCIENCE, 2009, 340 (1-2) : 214 - 220
  • [39] Effect of SMM concentration on morphology and performance of surface modified PVDF hollow fiber membrane contactor for CO2 absorption
    Rahbari-Sisakht, M.
    Ismail, A. F.
    Rana, D.
    Matsuura, T.
    Emadzadeh, D.
    SEPARATION AND PURIFICATION TECHNOLOGY, 2013, 116 : 67 - 72
  • [40] Effect of bore fluid composition on structure and performance of asymmetric polysulfone hollow fiber membrane contactor for CO2 absorption
    Rahbari-sisakht, M.
    Ismail, A. F.
    Matsuura, T.
    SEPARATION AND PURIFICATION TECHNOLOGY, 2012, 88 : 99 - 106