Study on CO2 absorption performance of lab-scale ceramic hollow fiber membrane contactor by gas/liquid flow direction and module design

被引:56
|
作者
Lee, Hong Joo [1 ]
Park, Yu Gang [1 ]
Kim, Min Kwang [1 ]
Lee, Seung Hwan [1 ]
Park, Jung Hoon [1 ]
机构
[1] Dongguk Univ, Wonheung Gwan F619,30 Pildong Ro 1gil, Seoul 100715, South Korea
关键词
Membrane contactor; Ceramic hollow fiber membrane; Membrane contactor module; Module design; Scale-up; CARBON-DIOXIDE; GAS-ABSORPTION; CAPTURE; MORPHOLOGY; SOLVENTS; REMOVAL;
D O I
10.1016/j.seppur.2019.03.011
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Membrane contactor has been actively studied in recent years, but it is difficult to modulate the ceramic hollow fiber membranes because they are extremely brittle and poor in flexibility. For this reason, research on ceramic hollow fiber membrane contactor modules has been rarely carried out. In this study, hydrophobic modified ceramic hollow fiber membranes were fabricated by phase inversion method. 1-in. unit module, a 3-parallel connection module, and a 2.5-in. advanced module with the ceramic hollow fiber membranes were developed. A membrane contactor CO2 capture system with the module was set up and characteristics of ceramic hollow fiber membrane contactor were analyzed. The highest CO2 absorption property was observed in the configuration in which the liquid flows on the shell side from the bottom to the top, and the gas and the liquid contacts in the counter-current. In addition, a lab-scale ceramic hollow fiber membrane contactor unit module was successfully developed to treat 0.175 Nm(3)/h flue gas with 90% CO2 removal efficiency. To the best of my knowledge, this is the first case of CO2 absorption experiment using hydrophobic ceramic hollow fiber membrane contactor module instead of the polymeric membrane module or single ceramic membrane. These results are expected to be very valuable as fundamental and important data for scale-up of ceramic membrane contactor process.
引用
收藏
页码:189 / 196
页数:8
相关论文
共 50 条
  • [1] Temperature and pressure dependence of the CO2 absorption through a ceramic hollow fiber membrane contactor module
    Lee, Hong Joo
    Kim, Min Kwang
    Park, Jung Hoon
    Magnone, Edoardo
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2020, 150
  • [2] Investigation on the Performance of CO2 Absorption in Ceramic Hollow-Fiber Gas/Liquid Membrane Contactors
    Ho, Chii-Dong
    Chang, Hsuan
    Chen, Yu-Han
    Chew, Thiam Leng
    Ke, Jui-Wei
    MEMBRANES, 2023, 13 (02)
  • [3] Experimental Study of CO2 Absorption in a Hollow Fiber Membrane Contactor
    Kallas, Therese
    Chabanon, Elodie
    Germain, Guillaume
    Bouallou, Chakib
    PRES'09: 12TH INTERNATIONAL CONFERENCE ON PROCESS INTEGRATION, MODELLING AND OPTIMISATION FOR ENERGY SAVING AND POLLUTION REDUCTION, PTS 1 AND 2, 2009, 18 : 267 - 272
  • [4] Effect of PVDF concentration on the morphology and performance of hollow fiber membrane employed as gas-liquid membrane contactor for CO2 absorption
    Ghasem, Nayef
    Al-Marzouqi, Mohamed
    Duidar, Ali
    SEPARATION AND PURIFICATION TECHNOLOGY, 2012, 98 : 174 - 185
  • [5] Modeling and experimental study of CO2 absorption in a hollow fiber membrane contactor
    Zhang, Hong-Yan
    Wang, Rong
    Liang, David Tee
    Tay, Joo Hwa
    JOURNAL OF MEMBRANE SCIENCE, 2006, 279 (1-2) : 301 - 310
  • [6] Modeling and experimental study of CO2 absorption in a hollow fiber membrane contactor
    School of Civil and Environmental Engineering, Nanyang Technological University, Singapore, 639798, Singapore
    不详
    J. Membr. Sci., 2006, 1-2 (301-310):
  • [7] Performance improvement of countercurrent-flow membrane gas absorption in a hollow fiber gas-liquid membrane contactor
    Ho, Chii-Dong
    Sung, Yun-Jen
    Chen, Wei-Ting
    Tsai, Feng-Chi
    MEMBRANE WATER TREATMENT, 2017, 8 (01) : 35 - 50
  • [8] Hollow fiber membrane contactors for CO2 capture: from lab-scale screening to pilot-plant module conception
    Porcheron, Fabien
    Ferre, Daniel
    Favre, Eric
    Phuc Tien Nguyen
    Lorain, Olivier
    Mercier, Regis
    Rougeau, Laurent
    10TH INTERNATIONAL CONFERENCE ON GREENHOUSE GAS CONTROL TECHNOLOGIES, 2011, 4 : 763 - 770
  • [9] PVDF/CaCO3 composite hollow fiber membrane for CO2 absorption in gas-liquid membrane contactor
    Fosi-Kofal, M.
    Mustafa, A.
    Ismail, A. F.
    Rezaei-DashtArzhandi, M.
    Matsuura, T.
    JOURNAL OF NATURAL GAS SCIENCE AND ENGINEERING, 2016, 31 : 428 - 436
  • [10] HOLLOW FIBER MEMBRANE CONTACTOR ABSORPTION OF CO2 FROM THE FLUE GAS: REVIEW AND PERSPECTIVE
    Zhang, Z. E.
    Yan, Y. F.
    Zhang, L.
    Ju, S. X.
    GLOBAL NEST JOURNAL, 2014, 16 (02): : 354 - 373