Effect of transverse magnetic fields on dose distribution and RBE of photon beams: comparing PENELOPE and EGS4 Monte Carlo codes

被引:11
|
作者
Nettelbeck, H. [1 ]
Takacs, G. J. [1 ]
Rosenfeld, A. B. [1 ]
机构
[1] Univ Wollongong, Ctr Med Radiat Phys, Wollongong, NSW 2522, Australia
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2008年 / 53卷 / 18期
关键词
D O I
10.1088/0031-9155/53/18/018
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The application of a strong transverse magnetic field to a volume undergoing irradiation by a photon beam can produce localized regions of dose enhancement and dose reduction. This study uses the PENELOPE Monte Carlo code to investigate the effect of a slice of uniform transverse magnetic field on a photon beam using different magnetic field strengths and photon beam energies. The maximum and minimum dose yields obtained in the regions of dose enhancement and dose reduction are compared to those obtained with the EGS4 Monte Carlo code in a study by Li et al ( 2001), who investigated the effect of a slice of uniform transverse magnetic field ( 1 to 20 Tesla) applied to high-energy photon beams. PENELOPE simulations yielded maximum dose enhancements and dose reductions as much as 111% and 77%, respectively, where most results were within 6% of the EGS4 result. Further PENELOPE simulations were performed with the Sheikh-Bagheri and Rogers ( 2002) input spectra for 6, 10 and 15 MV photon beams, yielding results within 4% of those obtained with the Mohan et al ( 1985) spectra. Small discrepancies between a few of the EGS4 and PENELOPE results prompted an investigation into the influence of the PENELOPE elastic scattering parameters C1 and C2 and low-energy electron and photon transport cut-offs. Repeating the simulations with smaller scoring bins improved the resolution of the regions of dose enhancement and dose reduction, especially near the magnetic field boundaries where the dose deposition can abruptly increase or decrease. This study also investigates the effect of a magnetic field on the low-energy electron spectrum that may correspond to a change in the radiobiological effectiveness (RBE). Simulations show that the increase in dose is achieved predominantly through the lower energy electron population.
引用
收藏
页码:5123 / 5137
页数:15
相关论文
共 50 条
  • [1] GENERATION OF PHOTON DOSE SPREAD ARRAYS USING THE EGS4 MONTE-CARLO CODE
    MACKIE, TR
    BLAIR, A
    BIELAJEW, AF
    ROGERS, DWO
    BATTISTA, JJ
    MEDICAL PHYSICS, 1985, 12 (04) : 515 - 515
  • [2] EGS4 Monte Carlo pencil beam dose calculation for IMRT optimization
    Earl, MA
    Li, XA
    Shepard, D
    Yu, CX
    MEDICAL PHYSICS, 2002, 29 (06) : 1256 - 1256
  • [3] The dose distribution close to an Ir-192 wire source: EGS4 Monte Carlo calculations
    Cheung, YC
    Yu, PKN
    Young, ECM
    Chan, CL
    Ng, MF
    Tang, F
    PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (02): : 401 - 406
  • [4] Comparison of synchrotron radiation calculations between analytical codes (STAC8, PHOTON) and Monte Carlo codes (FLUKA, EGS4)
    Liu, JC
    Fasso, A
    Prinz, A
    Rokni, S
    Asano, Y
    RADIATION PROTECTION DOSIMETRY, 2005, 116 (1-4) : 658 - 661
  • [5] MONTE CARLO CALCULATION ON THE DOSE MODULATION EFFECT USING DYNAMIC MAGNETIC FIELDS IN PHOTON BEAMS
    Cho, M. J.
    Kim, K. Hwan
    Oh, Y. Kee
    Shin, K. Chul
    Kim, J. Kee
    Jeong, D. Hyeok
    Kim, J. Kee
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S410 - S410
  • [6] EGS4 MONTE-CARLO DETERMINATION OF THE BETA-DOSE KERNEL IN WATER
    SIMPKIN, DJ
    MACKIE, TR
    MEDICAL PHYSICS, 1990, 17 (02) : 179 - 186
  • [7] Comparison of EGS4 and MCNP Monte Carlo codes when calculating radiotherapy depth doses
    Love, PA
    Lewis, DG
    Al-Affan, IAM
    Smith, CW
    PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (05): : 1351 - 1357
  • [8] Benchmark of PENELOPE code for low-energy photon transport: dose comparisons with MCNP4 and EGS4
    Ye, SJ
    Brezovich, IA
    Pareek, P
    Naqvi, SA
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (03): : 387 - 397
  • [9] Comparison of EGS4 and MCNP4b Monte Carlo codes for generation of photon phase space distributions for a Varian 2100C
    Siebers, JV
    Keall, PJ
    Libby, B
    Mohan, R
    PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (12): : 3009 - 3026
  • [10] Dosimetric comparison of Monte Carlo codes (EGS4, MCNP, MCNPX) considering external and internal exposures of the Zubal phantom to electron and photon sources
    Chiavassa, S
    Lemosquet, A
    Aubineau-Lanièce, I
    de Carlan, L
    Clairand, I
    Ferrer, L
    Bardiès, M
    Franck, D
    Zankl, M
    RADIATION PROTECTION DOSIMETRY, 2005, 116 (1-4) : 631 - 635