Effect of transverse magnetic fields on dose distribution and RBE of photon beams: comparing PENELOPE and EGS4 Monte Carlo codes

被引:11
|
作者
Nettelbeck, H. [1 ]
Takacs, G. J. [1 ]
Rosenfeld, A. B. [1 ]
机构
[1] Univ Wollongong, Ctr Med Radiat Phys, Wollongong, NSW 2522, Australia
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2008年 / 53卷 / 18期
关键词
D O I
10.1088/0031-9155/53/18/018
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The application of a strong transverse magnetic field to a volume undergoing irradiation by a photon beam can produce localized regions of dose enhancement and dose reduction. This study uses the PENELOPE Monte Carlo code to investigate the effect of a slice of uniform transverse magnetic field on a photon beam using different magnetic field strengths and photon beam energies. The maximum and minimum dose yields obtained in the regions of dose enhancement and dose reduction are compared to those obtained with the EGS4 Monte Carlo code in a study by Li et al ( 2001), who investigated the effect of a slice of uniform transverse magnetic field ( 1 to 20 Tesla) applied to high-energy photon beams. PENELOPE simulations yielded maximum dose enhancements and dose reductions as much as 111% and 77%, respectively, where most results were within 6% of the EGS4 result. Further PENELOPE simulations were performed with the Sheikh-Bagheri and Rogers ( 2002) input spectra for 6, 10 and 15 MV photon beams, yielding results within 4% of those obtained with the Mohan et al ( 1985) spectra. Small discrepancies between a few of the EGS4 and PENELOPE results prompted an investigation into the influence of the PENELOPE elastic scattering parameters C1 and C2 and low-energy electron and photon transport cut-offs. Repeating the simulations with smaller scoring bins improved the resolution of the regions of dose enhancement and dose reduction, especially near the magnetic field boundaries where the dose deposition can abruptly increase or decrease. This study also investigates the effect of a magnetic field on the low-energy electron spectrum that may correspond to a change in the radiobiological effectiveness (RBE). Simulations show that the increase in dose is achieved predominantly through the lower energy electron population.
引用
收藏
页码:5123 / 5137
页数:15
相关论文
共 50 条
  • [41] Monte Carlo dose voxel kernel calculations of beta-emitting and Auger-emitting radionuclides for internal dosimetry: A comparison between EGSnrcMP and EGS4
    Strigari, Lidia
    Menghi, Enrico
    D'Andrea, Marco
    Benassi, Marcello
    MEDICAL PHYSICS, 2006, 33 (09) : 3383 - 3389
  • [42] Benchmarking a GATE/Geant4 Monte Carlo model for proton beams in magnetic fields
    Padilla-Cabal, Fatima
    Alejandro Fragoso, Jose
    Resch, Andreas Franz
    Georg, Dietmar
    Fuchs, Hermann
    MEDICAL PHYSICS, 2020, 47 (01) : 223 - 233
  • [43] Comparison of Electron Dose-Point Kernels in Water Generated by the Monte Carlo Codes, PENELOPE, GEANT4, MCNPX, and ETRAN
    Uusijarvi, Helena
    Chouin, Nicolas
    Bernhardt, Peter
    Ferrer, Ludovic
    Bardies, Manuel
    Forssell-Aronsson, Eva
    CANCER BIOTHERAPY AND RADIOPHARMACEUTICALS, 2009, 24 (04) : 461 - 467
  • [44] Stereotactic dose planning system used in Leksell Gamma Knife model-B: EGS4 Monte Carlo versus GafChromic films MD-55
    Cheung, YC
    Yu, KN
    Ho, RTK
    Yu, CP
    APPLIED RADIATION AND ISOTOPES, 2000, 53 (03) : 427 - 430
  • [45] Depth dose enhancement of electron beams subject to external uniform longitudinal magnetic fields: A Monte Carlo study
    Earl, MA
    Ma, L
    MEDICAL PHYSICS, 2002, 29 (04) : 484 - 491
  • [46] Distributions Dose Analysis for 6 MV Photon Beams Using Monte Carlo-GEANT4 Simulation
    Qomariyah, Nurul
    Wirawan, Rahadi
    Mardiana, Laili
    Al Hadi, Kasnawi
    8TH NATIONAL PHYSICS SEMINAR 2019, 2019, 2169
  • [47] Evaluation of Beam Deflection, Longitudinal Retraction and Depth-Dose Perturbation of Helium Ion Beams under Transverse Magnetic Fields: A Monte Carlo Simulation Study
    Nahid Hajiloo
    Moscow University Physics Bulletin, 2022, 77 : 868 - 877
  • [48] Evaluation of Beam Deflection, Longitudinal Retraction and Depth-Dose Perturbation of Helium Ion Beams under Transverse Magnetic Fields: A Monte Carlo Simulation Study
    Hajiloo, Nahid
    MOSCOW UNIVERSITY PHYSICS BULLETIN, 2022, 77 (06) : 868 - 877
  • [49] Monte Carlo simulation of the effect of magnetic fields on brachytherapy dose distributions in lung tissue material
    Moreno-Barbosa, Fernando
    de Celis-Alonso, Benito
    Moreno-Barbosa, Eduardo
    Hernandez-Lopez, Javier Miguel
    Geoghegan, Theodore
    Ramos-Mendez, Jose
    PLOS ONE, 2020, 15 (10):
  • [50] Dose-mean lineal energy values for electrons by different Monte Carlo codes: Consequences for estimates of radiation quality in photon beams
    Lindborg, Lennart
    Lillhok, Jan
    Kyriakou, Ioanna
    Emfietzoglou, Dimitris
    MEDICAL PHYSICS, 2022, 49 (02) : 1286 - 1296