A numerical study on the effect of column layout on air distribution and performance of column attachment ventilation

被引:28
|
作者
Yin, Haiguo [1 ]
Li, Linna [1 ]
Wu, Rui [1 ]
Wang, Yuanyuan [1 ]
Li, Angui [1 ]
机构
[1] Xian Univ Architecture & Technol, Sch Bldg Serv Sci & Engn, Xian 710055, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
column attachment ventilation; air distribution; column layout; performance evaluation; large space buildings; IMPINGING JET VENTILATION; STRATUM VENTILATION; DISPLACEMENT VENTILATION; THERMAL ENVIRONMENT; COOLING SYSTEM; DESIGN; FLOW;
D O I
10.1007/s12273-020-0699-x
中图分类号
O414.1 [热力学];
学科分类号
摘要
Based on the structural characteristics of existing buildings and the disadvantages of current mixed ventilation mode in the application to large space buildings, an original column attachment ventilation (CAV) has been proposed. In this study, the experiment utilized a room space with four columns uniformly distributed in the space to visualize the movement of attached airflow along the cylinder surface and the floor, the numerical technique was employed to study the effects of the column layout (i.e., uniform, centralized, dispersed, and crossed distribution) on the air distribution of CAV mode in a standard four-column full scale model of a shopping mall. Seven indices, including airflow pattern, air diffusion performance index (ADPI), air temperature distribution, heat removal effectiveness, draught rate (DR), predicted mean vote (PMV), and carbon dioxide (CO2) concentration, were used to assess the ventilation performance. In the CAV mode with a uniform column layout scheme, the experimental results indicated that the air supply flows downward along the wall surface, forming a secondary attachment with the ground and spreading along the floor in a fan radiation flow mode. Further, an "air lake"-like speed and temperature distribution similar to displacement ventilation (DV) was formed in the occupied zone. In all simulation cases, it was found that the average air velocity was less than 0.25 m/s in occupied zone, the effectiveness for heat removal was more significant than 1.0, DR value was less than 20%, the PMV level can also satisfy most people. The average CO(2)concentration was around 470 ppm in the occupied breathing zone. These results indicated that the CAV mode could be an efficient air distribution method. They demonstrated the technical feasibility of applying the CAV in the space under different column layout schemes.
引用
收藏
页码:1095 / 1108
页数:14
相关论文
共 50 条
  • [21] Numerical simulation of thermal performance of a square column
    Tang, MF
    Chen, QG
    BUILDING AND ENVIRONMENT, 1997, 32 (05) : 411 - 415
  • [22] Study on Ventilation Effectiveness of Circular Column Attached Displacement Ventilation Mode
    Yin, Haiguo
    Wu, Rui
    Chen, Ting
    Sun, Yixiang
    Li, Angui
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 3511 - 3518
  • [23] The impact of flow distribution on column performance: A computational fluid dynamics study
    Smits, Wim
    Deridder, Sander
    Desmet, Gert
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1369 : 125 - 130
  • [24] A column study of effect of filter media on the performance of sand filter
    Kim, Tae-hoon
    Oh, Heekyong
    Eom, Jungyeol
    Park, ChulHwi
    MEMBRANE AND WATER TREATMENT, 2020, 11 (04): : 247 - 255
  • [25] A study of ventilation performance of an underfloor and overhead air distribution system
    Chang, Jae D.
    FIRST INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT, PROCEEDINGS VOLS 1-3, 2008, : 1202 - 1209
  • [26] Numerical study on ventilation duct layout in subway stations for smoke control performance optimization
    Chen, Junfeng
    Dong, Yang
    Zhong, Maohua
    Hua, Fucai
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2025, 258
  • [27] Numerical study of the air-flow in an oscillating water column wave energy converter
    Conde, J. M. Paixao
    Gato, L. M. C.
    RENEWABLE ENERGY, 2008, 33 (12) : 2637 - 2644
  • [28] Numerical Analysis to Compare the Performance of an Oscillating Water Column Device with Different Air Chamber Geometry
    Raghavendra, S.
    Marulasiddappa, Sreedhara B.
    Manoj, A.
    Praveen, K. M.
    JOURNAL OF WATERWAY PORT COASTAL AND OCEAN ENGINEERING, 2025, 151 (03)
  • [29] Numerical study of a planar shock interacting with a cylindrical water column embedded with an air cavity
    Xiang, Gaoming
    Wang, Bing
    JOURNAL OF FLUID MECHANICS, 2017, 825 : 825 - 852
  • [30] Effect of air capacity and air resistance on measurement of instantaneous pressure drop of column weight in pulsed extraction column
    Zeng, Xin
    Li, Shao-Wei
    Jing, Shan
    Liu, Ji-Lian
    Wu, Qiu-Lin
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2015, 49 (06): : 997 - 1004