Optimization and Validation of Real Time PCR Assays for Absolute Quantification of toxigenic Vibrio cholerae and Escherichia coli

被引:0
|
作者
Ferdous, J. [1 ,2 ]
Hossain, Z. Z. [1 ,2 ]
Tulsiani, S. [2 ,3 ]
Rashid, R. B. [1 ]
Jensen, P. K. M. [2 ,3 ]
Begum, A. [1 ]
机构
[1] Univ Dhaka, Dept Microbiol, Dhaka 1000, Bangladesh
[2] Univ Copenhagen, Inst Publ Hlth, Sect Global Hlth, Oster Farimagsgade 5a,Bldg 9, DK-1353 Copenhagen, Denmark
[3] Univ Copenhagen, Copenhagen Ctr Disaster Res, Oster Farimagsgade 5a,Bldg 24, DK-1353 Copenhagen, Denmark
关键词
QUANTITATIVE PCR; CHESAPEAKE BAY; CULTURE METHOD; WATER SAMPLES; TRANSMISSION; SEAWATER; GENE; O139;
D O I
暂无
中图分类号
R38 [医学寄生虫学]; Q [生物科学];
学科分类号
07 ; 0710 ; 09 ; 100103 ;
摘要
Quantitative real-time PCR (qPCR) is a dynamic and cogent assay for the detection and quantification of specified nucleic acid sequences and is more accurate compared to both traditional culture based techniques and 'end point' conventional PCR. Serial dilution of bacterial cell culture provides information on colony forming unit (CFU) counts. This is crucial for obtaining optimal standard curves representative of DNA concentration. This approach eliminates variation in the standard curves caused by loss of DNA by serial dilution of nucleic acid elute. In this study, an assay was developed to detect and quantify DNA by real-time PCR for two pathogenic species, Escherichia coli (E. coli) and Vibrio cholerae (V. cholerae). In order to generate a standard curve, total bacterial DNA was diluted in a 10-fold series and each sample was adjusted to an estimated cell count. The starting bacterial DNA concentration was 11ng/mu L. An individual E. coli cell has approximately 5.16 femtograms of DNA. Therefore, 11 ng/mu L of DNA would indicate 2.48x10(7) cells. Both SYBR Green and TaqMan assays were validated for uidA region in E. coli and ctxA region in V. cholerae, respectively and was based on previously published assays for this standard curve experiment. PCR efficiency for uidA gene and ctxA gene were obtained 103.8% and 99.21%, respectively. Analysis of Variance (ANOVA) and coefficient of variation (CV %) indicated that standard curve generated by genomic DNA dilution had higher repeatability. Although not statistically significant, low F ratios indicated that there was some variation in CT values when genomic DNA dilution was compared to dilution of cell suspension in media. Different water samples spiked with pure cultures of E. coli and V. cholerae were used as unknown samples. The standard curve constructed by the serial dilution of genomic DNA exhibited greater efficiency when compared to that of the standard curve obtained from serial dilution of cell suspension since in the former method DNA is not lost during extraction from culture dilutions.
引用
收藏
页码:641 / 651
页数:11
相关论文
共 50 条
  • [31] Evaluation of real time PCR assays for the detection and enumeration of enterohemorrhagic Escherichia coli directly from cattle feces
    Luedtke, Brandon E.
    Bono, James L.
    Bosilevac, Joseph M.
    JOURNAL OF MICROBIOLOGICAL METHODS, 2014, 105 : 72 - 79
  • [32] QUANTIFICATION OF HAEMATOPOIETIC CHIMERISM BY REAL TIME PCR ASSAY VALIDATION
    Kooloos, K.
    CYTOTHERAPY, 2013, 15 (04) : S23 - S23
  • [33] Absolute quantification of viable Vibrio cholerae in seawater samples using multiplex droplet digital PCR combined with propidium monoazide
    Yang, Jinsong
    Xu, Haibin
    Ke, Zili
    Kan, Naipeng
    Zheng, Enhui
    Qiu, Yufeng
    Huang, Mengying
    FRONTIERS IN MICROBIOLOGY, 2023, 14
  • [34] Absolute Quantification of Viable but Nonculturable Vibrio cholerae Using Droplet Digital PCR with Oil-Enveloped Bacterial Cells
    Zhao, Shuo
    Lu, Xin
    Zhang, JingYun
    Kan, Biao
    MICROBIOLOGY SPECTRUM, 2022, 10 (04):
  • [35] Determination of Temperature Sensitive Plasmid Copy Number in Escherichia coli by Absolute and Relative Real Time Quantitation PCR
    Jiang, Xianzhang
    Liu, Hongjiao
    Niu, Yongchao
    Hu, Meirong
    Qi, Feng
    Zhang, Mingliang
    Huang, Jianzhong
    Tao, Yong
    JUNDISHAPUR JOURNAL OF MICROBIOLOGY, 2017, 10 (07)
  • [36] PCR detection of Vibrio cholerae, Escherichia coli, and Salmonella sp. from bottled drinking water in Iran
    Bonyadian, Mojtaba
    Moshtghi, Hamdallah
    Nadi, Hanie
    JOURNAL OF INFECTION IN DEVELOPING COUNTRIES, 2018, 12 (09): : 700 - 705
  • [37] Quadruplex Real-Time PCR Assay for Detection and Identification of Vibrio cholerae O1 and O139 Strains and Determination of Their Toxigenic Potential
    Huang, Jianwei
    Zhu, Yumei
    Wen, Huixin
    Zhang, Jiafeng
    Huang, Shijie
    Niu, Jianjun
    Li, Qingge
    APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2009, 75 (22) : 6981 - 6985
  • [38] Real-time PCR and NASBA for rapid and sensitive detection of Vibrio cholerae in ballast water
    Fykse, Else M.
    Nilsen, Trine
    Nielsen, Agnete Dessen
    Tryland, Ingun
    Delacroix, Stephanie
    Blatny, Janet M.
    MARINE POLLUTION BULLETIN, 2012, 64 (02) : 200 - 206
  • [39] Molecular-beacon multiplex real-time PCR assay for detection of Vibrio cholerae
    Gubala, Aneta J.
    Proll, David F.
    APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2006, 72 (09) : 6424 - 6428
  • [40] Validation of real-time PCR assays for transgenic grapevine analysis
    Savazzini, E.
    Ciabatti, I.
    Paterno, A.
    Marchesi, U.
    Amaddeo, D.
    Martinelli, L.
    IN VITRO CELLULAR & DEVELOPMENTAL BIOLOGY-ANIMAL, 2005, 41 : 50A - 50A