Optimization and Validation of Real Time PCR Assays for Absolute Quantification of toxigenic Vibrio cholerae and Escherichia coli

被引:0
|
作者
Ferdous, J. [1 ,2 ]
Hossain, Z. Z. [1 ,2 ]
Tulsiani, S. [2 ,3 ]
Rashid, R. B. [1 ]
Jensen, P. K. M. [2 ,3 ]
Begum, A. [1 ]
机构
[1] Univ Dhaka, Dept Microbiol, Dhaka 1000, Bangladesh
[2] Univ Copenhagen, Inst Publ Hlth, Sect Global Hlth, Oster Farimagsgade 5a,Bldg 9, DK-1353 Copenhagen, Denmark
[3] Univ Copenhagen, Copenhagen Ctr Disaster Res, Oster Farimagsgade 5a,Bldg 24, DK-1353 Copenhagen, Denmark
关键词
QUANTITATIVE PCR; CHESAPEAKE BAY; CULTURE METHOD; WATER SAMPLES; TRANSMISSION; SEAWATER; GENE; O139;
D O I
暂无
中图分类号
R38 [医学寄生虫学]; Q [生物科学];
学科分类号
07 ; 0710 ; 09 ; 100103 ;
摘要
Quantitative real-time PCR (qPCR) is a dynamic and cogent assay for the detection and quantification of specified nucleic acid sequences and is more accurate compared to both traditional culture based techniques and 'end point' conventional PCR. Serial dilution of bacterial cell culture provides information on colony forming unit (CFU) counts. This is crucial for obtaining optimal standard curves representative of DNA concentration. This approach eliminates variation in the standard curves caused by loss of DNA by serial dilution of nucleic acid elute. In this study, an assay was developed to detect and quantify DNA by real-time PCR for two pathogenic species, Escherichia coli (E. coli) and Vibrio cholerae (V. cholerae). In order to generate a standard curve, total bacterial DNA was diluted in a 10-fold series and each sample was adjusted to an estimated cell count. The starting bacterial DNA concentration was 11ng/mu L. An individual E. coli cell has approximately 5.16 femtograms of DNA. Therefore, 11 ng/mu L of DNA would indicate 2.48x10(7) cells. Both SYBR Green and TaqMan assays were validated for uidA region in E. coli and ctxA region in V. cholerae, respectively and was based on previously published assays for this standard curve experiment. PCR efficiency for uidA gene and ctxA gene were obtained 103.8% and 99.21%, respectively. Analysis of Variance (ANOVA) and coefficient of variation (CV %) indicated that standard curve generated by genomic DNA dilution had higher repeatability. Although not statistically significant, low F ratios indicated that there was some variation in CT values when genomic DNA dilution was compared to dilution of cell suspension in media. Different water samples spiked with pure cultures of E. coli and V. cholerae were used as unknown samples. The standard curve constructed by the serial dilution of genomic DNA exhibited greater efficiency when compared to that of the standard curve obtained from serial dilution of cell suspension since in the former method DNA is not lost during extraction from culture dilutions.
引用
收藏
页码:641 / 651
页数:11
相关论文
共 50 条
  • [21] Selective media and real-time PCR assays for the effective detection of enterotoxigenic Escherichia coli in vegetables
    Ohtsuka, Kayoko
    Hoshino, Kozue
    Kadowaki, Natsuko
    Ohsaka, Misa
    Konishi, Noriko
    Obata, Hiromi
    Kai, Akemi
    Terajima, Jun
    Hara-Kudo, Yukiko
    LWT-FOOD SCIENCE AND TECHNOLOGY, 2019, 114
  • [22] Taqman Real-Time PCR Assays for Rapid Detection of Avian Pathogenic Escherichia coli Isolates
    Ikuta, Nilo
    Solla Sobral, Fabiana de Oliveira
    Moreira Lehmann, Fernanda Kieling
    da Silveira, Vinicius Proenca
    de Carli, Silvia
    Casanova, Yara Silva
    Celmer, Alvaro Jose
    Kazantzi Fonseca, Andre Salvador
    Lunge, Vagner Ricardo
    AVIAN DISEASES, 2014, 58 (04) : 628 - 631
  • [23] Real-time PCR assays for detection and quantification of sweetpotato viruses
    Kokkinos, C. D.
    Clark, C. A.
    PLANT DISEASE, 2006, 90 (06) : 783 - 788
  • [24] Detection of enteropathogenic Vibrio parahaemolyticus, Vibrio cholerae and Vibrio vulnificus: performance of real-time PCR kits in an interlaboratory study
    Erik Eschbach
    Annett Martin
    Jennifer Huhn
    Constanze Seidel
    Ralf Heuer
    Jan-Hendrik Schumacher
    Stefan Ulrich
    Jens-Oliver Axe
    Antje Konietzny
    Eckhard Strauch
    Boris Oberheitmann
    European Food Research and Technology, 2017, 243 : 1335 - 1342
  • [25] Detection of enteropathogenic Vibrio parahaemolyticus, Vibrio cholerae and Vibrio vulnificus: performance of real-time PCR kits in an interlaboratory study
    Eschbach, Erik
    Martin, Annett
    Huhn, Jennifer
    Seidel, Constanze
    Heuer, Ralf
    Schumacher, Jan-Hendrik
    Ulrich, Stefan
    Axe, Jens-Oliver
    Konietzny, Antje
    Strauch, Eckhard
    Oberheitmann, Boris
    EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2017, 243 (08) : 1335 - 1342
  • [26] Real-time PCR assays for the detection and quantification of Streptococcus pneumoniae
    Park, Hee Kuk
    Lee, Hee Jung
    Kim, Wonyong
    FEMS MICROBIOLOGY LETTERS, 2010, 310 (01) : 48 - 53
  • [27] Absolute quantification by droplet digital PCR versus analog real-time PCR
    Hindson, Christopher M.
    Chevillet, John R.
    Briggs, Hilary A.
    Gallichotte, Emily N.
    Ruf, Ingrid K.
    Hindson, Benjamin J.
    Vessella, Robert L.
    Tewari, Muneesh
    NATURE METHODS, 2013, 10 (10) : 1003 - +
  • [28] Absolute quantification by droplet digital PCR versus analog real-time PCR
    Christopher M Hindson
    John R Chevillet
    Hilary A Briggs
    Emily N Gallichotte
    Ingrid K Ruf
    Benjamin J Hindson
    Robert L Vessella
    Muneesh Tewari
    Nature Methods, 2013, 10 : 1003 - 1005
  • [29] Real-time quantitative PCR: A tool for absolute and relative quantification
    Harshitha, Ravikumar
    Arunraj, Duraipandian Rex
    BIOCHEMISTRY AND MOLECULAR BIOLOGY EDUCATION, 2021, 49 (05) : 800 - 812
  • [30] A method for the absolute quantification of cDNA using real-time PCR
    Whelan, JA
    Russell, NB
    Whelan, MA
    JOURNAL OF IMMUNOLOGICAL METHODS, 2003, 278 (1-2) : 261 - 269