Optimization and Validation of Real Time PCR Assays for Absolute Quantification of toxigenic Vibrio cholerae and Escherichia coli

被引:0
|
作者
Ferdous, J. [1 ,2 ]
Hossain, Z. Z. [1 ,2 ]
Tulsiani, S. [2 ,3 ]
Rashid, R. B. [1 ]
Jensen, P. K. M. [2 ,3 ]
Begum, A. [1 ]
机构
[1] Univ Dhaka, Dept Microbiol, Dhaka 1000, Bangladesh
[2] Univ Copenhagen, Inst Publ Hlth, Sect Global Hlth, Oster Farimagsgade 5a,Bldg 9, DK-1353 Copenhagen, Denmark
[3] Univ Copenhagen, Copenhagen Ctr Disaster Res, Oster Farimagsgade 5a,Bldg 24, DK-1353 Copenhagen, Denmark
关键词
QUANTITATIVE PCR; CHESAPEAKE BAY; CULTURE METHOD; WATER SAMPLES; TRANSMISSION; SEAWATER; GENE; O139;
D O I
暂无
中图分类号
R38 [医学寄生虫学]; Q [生物科学];
学科分类号
07 ; 0710 ; 09 ; 100103 ;
摘要
Quantitative real-time PCR (qPCR) is a dynamic and cogent assay for the detection and quantification of specified nucleic acid sequences and is more accurate compared to both traditional culture based techniques and 'end point' conventional PCR. Serial dilution of bacterial cell culture provides information on colony forming unit (CFU) counts. This is crucial for obtaining optimal standard curves representative of DNA concentration. This approach eliminates variation in the standard curves caused by loss of DNA by serial dilution of nucleic acid elute. In this study, an assay was developed to detect and quantify DNA by real-time PCR for two pathogenic species, Escherichia coli (E. coli) and Vibrio cholerae (V. cholerae). In order to generate a standard curve, total bacterial DNA was diluted in a 10-fold series and each sample was adjusted to an estimated cell count. The starting bacterial DNA concentration was 11ng/mu L. An individual E. coli cell has approximately 5.16 femtograms of DNA. Therefore, 11 ng/mu L of DNA would indicate 2.48x10(7) cells. Both SYBR Green and TaqMan assays were validated for uidA region in E. coli and ctxA region in V. cholerae, respectively and was based on previously published assays for this standard curve experiment. PCR efficiency for uidA gene and ctxA gene were obtained 103.8% and 99.21%, respectively. Analysis of Variance (ANOVA) and coefficient of variation (CV %) indicated that standard curve generated by genomic DNA dilution had higher repeatability. Although not statistically significant, low F ratios indicated that there was some variation in CT values when genomic DNA dilution was compared to dilution of cell suspension in media. Different water samples spiked with pure cultures of E. coli and V. cholerae were used as unknown samples. The standard curve constructed by the serial dilution of genomic DNA exhibited greater efficiency when compared to that of the standard curve obtained from serial dilution of cell suspension since in the former method DNA is not lost during extraction from culture dilutions.
引用
收藏
页码:641 / 651
页数:11
相关论文
共 50 条
  • [1] Real-time PCR determination of rRNA gene copy number: absolute and relative quantification assays with Escherichia coli
    Changsoo Lee
    Seungyong Lee
    Seung Gu Shin
    Seokhwan Hwang
    Applied Microbiology and Biotechnology, 2008, 78 : 371 - 376
  • [2] Real-time PCR determination of rRNA gene copy number:: absolute and relative quantification assays with Escherichia coli
    Lee, Changsoo
    Lee, Seungyong
    Shin, Seung Gu
    Hwang, Seokhwan
    APPLIED MICROBIOLOGY AND BIOTECHNOLOGY, 2008, 78 (02) : 371 - 376
  • [3] Development and Validation of a Novel Real-Time Assay for the Detection and Quantification of Vibrio cholerae
    Bin Rashid, Ridwan
    Ferdous, Jannatul
    Tulsiani, Suhella
    Jensen, Peter Kjaer Mackie
    Begum, Anowara
    FRONTIERS IN PUBLIC HEALTH, 2017, 5
  • [4] Checklist for Optimization and Validation of Real-Time PCR Assays
    Raymaekers, Marijke
    Smets, Rita
    Maes, Brigitte
    Cartuyvels, Reinoud
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2009, 23 (03) : 145 - 151
  • [5] A Novel Triplex Quantitative PCR Strategy for Quantification of Toxigenic and Nontoxigenic Vibrio cholerae in Aquatic Environments
    Bliem, Rupert
    Schauer, Sonja
    Plicka, Helga
    Obwaller, Adelheid
    Sommer, Regina
    Steinrigl, Adolf
    Alam, Munirul
    Reischer, Georg H.
    Farnleitner, Andreas H.
    Kirschner, Alexander
    APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2015, 81 (09) : 3077 - 3085
  • [6] Multiplex real-time PCR detection of Vibrio cholerae
    Gubala, Aneta J.
    JOURNAL OF MICROBIOLOGICAL METHODS, 2006, 65 (02) : 278 - 293
  • [7] Real-time PCR assays for quantification and differentiation of Vibrio vulnificus strains in oysters and water
    Gordon, Katrina V.
    Vickery, Michael C.
    DePaola, Angelo
    Staley, Christopher
    Harwood, Valerie J.
    APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2008, 74 (06) : 1704 - 1709
  • [8] Application of SYBR Green Real-Time PCR for Detection of Toxigenic Vibrio cholerae O1 in the Aquatic Environment
    Tirapattanun, Aschana
    Chomvarin, Chariya
    Wongboot, Warawan
    Kanoktippornchai, Boonnapa
    CHIANG MAI JOURNAL OF SCIENCE, 2015, 42 (03): : 588 - 598
  • [9] Validation of real-time RT-PCR assays for mRNA quantification in baboons
    Overbergh, L
    Kyama, CM
    Valckx, D
    Debrock, S
    Mwenda, JM
    Mathieu, C
    D'Hooghe, T
    CYTOKINE, 2005, 31 (06) : 454 - 458
  • [10] Development of Real-Time PCR Assay for Detection of Vibrio cholerae
    Bielawska-Drozd, Agata
    Mirski, Tomasz
    Bartoszcze, Michal
    Cieslik, Piotr
    Roszkowiak, Anna
    Michalski, Aleksander
    POLISH JOURNAL OF ENVIRONMENTAL STUDIES, 2012, 21 (02): : 279 - 288