BIOMECHANICAL STRESS ANALYSIS OF BONE-IMPLANT INTERFACE

被引:0
|
作者
Fanali, S. [1 ]
Tramonte, S. U. [1 ]
Brunelli, G. [2 ]
Carinci, F. [3 ]
机构
[1] Univ G dAnnunzio, Dept Oral Sci Nano & Biotechnol, Chieti, Italy
[2] Don Orione Inst, Dept Dent & Maxillofacial Surg, Bergamo, Italy
[3] Univ Ferrara, Sect Maxillofacial Surg, Dept DMCCC, I-44100 Ferrara, Italy
关键词
D O I
暂无
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Over the last decade immediate load protocol has been revalued in the field of oral implantology with a view to achieve a simpler implantation protocol. This would lead to relevant advantages, such as a lower invasive impact of implantation and a shorter timing of treatment, with the patient regaining total masticatory functionality within the immediate post operative stage. In order to optimize the immediate load protocol and to foster implant osseointegration, the Italian Implantology School has developed soldering techniques by welding one or more stabilizing bars. Welding techniques allow obtaining a better primary stability in the early post-operatory period in comparison with non-supported implants, as micromovements are reduced and stress/strain distribution at bone-implant interface is more balanced. The present essay "Biomechanical stress analysis of bone-implant interface" is intended to study the distribution of stress/strain exerted by masticatory loads onto the pen-implant bone, with a view to decide whether the bar may be removed by completion of the healing process without relevant impact on bone strain. Secondly, it will be estimated whether the use of two bars undersized in diameter and symmetric to the implant can be compared with the application of one bar only. Finite Element analysis was performed. The results demonstrated that the use of a stiff definitive prosthesis (metal-porcelain) allows to remove the bar after 90 days' recovery, thus avoiding any cosmetic, hygienic and prosthetic contraindication.
引用
收藏
页码:25 / 31
页数:7
相关论文
共 50 条
  • [31] Modeling of ingrowth into implant cavities along the bone-implant interface
    Cowin, SC
    Luo, GM
    OSSEOINTEGRATION IN SKELETAL RECONSTRUCTION AND JOINT REPLACEMENT, 1997, : 57 - 72
  • [32] Efficacy of Resonance Frequency Analysis in the Diagnosis of Compromised Bone-Implant Interface
    Cavusoglu, Yeliz
    Sahin, Erdal
    Akca, Kivanc
    IMPLANT DENTISTRY, 2012, 21 (05) : 394 - 398
  • [33] Histomorphometrical analysis of the bone-implant interface: Comparison of microradiography and brightfield microscopy
    Parr, JA
    Young, T
    DunnJena, P
    Garetto, LP
    BIOMATERIALS, 1996, 17 (19) : 1921 - 1926
  • [34] The bone-implant interface - nanoscale analysis of clinically retrieved dental implants
    Shah, Furqan Ali
    Nilson, Bengt
    Branemark, Rickard
    Thomsen, Peter
    Palmquist, Anders
    NANOMEDICINE-NANOTECHNOLOGY BIOLOGY AND MEDICINE, 2014, 10 (08) : 1729 - 1737
  • [35] Evaluation of the Transfemoral Bone-Implant Interface Properties Using Vibration Analysis
    Mohamed, Mostafa
    Beaudry, Eric
    Shehata, Ahmed W.
    Raboud, Donald
    Hebert, Jacqueline S.
    Westover, Lindsey
    ANNALS OF BIOMEDICAL ENGINEERING, 2024, 52 (11) : 2987 - 3008
  • [36] Bone Response to Static Compressive Stress at Bone-Implant Interface: A Pilot Study of Critical Static Compressive Stress
    Ikumi, Noriharu
    Suzawa, Tetsuo
    Yoshimura, Kentaro
    Kamijo, Ryutaro
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2015, 30 (04) : 827 - 833
  • [37] Biomechanical Analysis of Mandibular Bone-Implant Construct With Three Implant Screw Design: A Finite Element Study
    Banerjee, Anik
    Choudhury, Sandeep
    Rana, Masud
    Chakraborty, Arindam
    Gupta, Abhisek
    Chowdhury, Amit Roy
    Journal of Engineering and Science in Medical Diagnostics and Therapy, 2023, 6 (03)
  • [38] Effects of Biomechanical Properties of the Bone-Implant Interface on Dental Implant Stability: From In Silico Approaches to the Patient's Mouth
    Haiat, Guillaume
    Wang, Hom-Lay
    Brunski, John
    ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, VOL 16, 2014, 16 : 187 - 213
  • [39] ELECTRON-MICROSCOPIC STUDY OF THE BONE-IMPLANT INTERFACE
    ROLAND, K
    DUFIEF, MP
    SHERIDAN, R
    HEUSON, JA
    MICRON AND MICROSCOPICA ACTA, 1987, 18 (03): : 209 - 209
  • [40] Study with speckle interferometry of bone-implant interface conditions
    Simoes, J
    Monteiro, J
    Vaz, M
    Taylor, M
    Blatcher, S
    EXPERIMENTAL MECHANICS, VOLS 1 AND 2: ADVANCES IN DESIGN, TESTING AND ANALYSIS, 1998, : 851 - 855