Capsule contraction after continuous curvilinear capsulorhexis: Poly(methyl methacrylate) versus silicone intraocular lenses

被引:53
|
作者
Cochener, B [1 ]
Jacq, PL [1 ]
Colin, J [1 ]
机构
[1] Univ Brest, Dept Ophthalmol, Brest, France
来源
JOURNAL OF CATARACT AND REFRACTIVE SURGERY | 1999年 / 25卷 / 10期
关键词
D O I
10.1016/S0886-3350(99)00227-8
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the progressive contraction of the anterior capsule opening after in the-bag implantation of 2 types of intraocular lenses (IOLs). Setting: Department of Ophthalmology, University of Brest, Brest, France. Methods: in this prospective study, 32 single-piece poly(methyl methacrylate) (PMMA) (Pharmacia 812 C) and 30 3-piece silicone IOLs with PMMA haptics (Allergan SI-40NB) were implanted in the bag after standardized phacoemulsification performed by the same surgeon. Aii patients were older than 70 years, and none had zonular weakness. The surface of continuous curvilinear capsulorhexis (CCC) was measured 1, 30, and 150 days postoperatively using a 3 charge-coupled device camera and a digitized computer analysis system, Results: A significant progressive constriction was observed at 150 days in 70% in the silicone group and 32% in the PMMA group. In addition, CCC contraction was greater in silicone group (P < .05). The mean surface decrease was 4.20 mm(2) in the silicone group and 1.53 mm(2) in the PMMA group. There was no correlation between sex, age, initial capsulorhexis area, and final capsule shrinkage. In some eyes, especially in those with a single-piece PMMA IOL (41 %), there was no constriction, but fine changes in the capsule opening were seen. Conclusion: Evolutive anterior capsulorhexis modifications were observed in all patients; however, the contraction rate was statistically higher in the silicone group. These results suggest that silicone IOL implantation should be avoided in eyes at risk for CCC constriction. (C) 1999 ASCRS and ESCRS.
引用
收藏
页码:1362 / 1369
页数:8
相关论文
共 50 条
  • [31] Biocompatibility of poly(methyl methacrylate), silicone, and AcrySof intraocular lenses: Randomized comparison of the cellular reaction on the anterior lens surface
    Hollick, EJ
    Spalton, DJ
    Ursell, PG
    Pande, MV
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (03): : 361 - 366
  • [32] INFLAMMATORY RESPONSE IN THE RABBIT EYE AFTER INTRAOCULAR IMPLANTATION WITH POLY(METHYL METHACRYLATE) AND HEPARIN SURFACE MODIFIED INTRAOCULAR LENSES
    LUNDGREN, B
    OCKLIND, A
    HOLST, A
    HARFSTRAND, A
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1992, 18 (01): : 65 - 70
  • [33] Anterior capsule stability in eyes with intraocular lenses made of poly(methylmethacrylate), silicone, and AcrySof
    Ursell, PG
    Spalton, DJ
    Pande, MV
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1997, 23 (10): : 1532 - 1538
  • [34] Posterior capsule opacification: Silicone plate-haptic versus AcrySof intraocular lenses
    Missier, KAA
    Nuijts, RMMA
    Tjia, KF
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (08): : 1569 - 1574
  • [35] 12 year results of a prospective trial comparing poly(methyl methacrylate) and poly(hydroxyethyl methacrylate) intraocular lenses
    Khan, AJ
    Percival, SPB
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1999, 25 (10): : 1404 - +
  • [36] Inflammation after phacoemulsification in diabetic retinopathy - Foldable acrylic versus heparin-surface-modified poly(methyl methacrylate) intraocular lenses
    Krepler, K
    Ries, E
    Derbolav, A
    Nepp, J
    Wedrich, A
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (02): : 233 - 238
  • [37] Effect of vancomycin on Staphylococcus epidermidis adherence to poly(methyl methacrylate) intraocular lenses
    Das, T
    Sharma, S
    Muralidhar, AV
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (04): : 703 - 708
  • [38] HAPTIC BREAKAGE IN ONE-PIECE POLY(METHYL METHACRYLATE) INTRAOCULAR LENSES
    AINSWORTH, JR
    SPENCER, AF
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1991, 17 (06): : 863 - 864
  • [39] Effect of AcrySof versus silicone or polymethyl methacrylate intraocular lens on posterior capsule opacification
    Li, Ni
    Chen, Xiaoming
    Zhang, Junjun
    Zhou, Yong
    Yao, Xun
    Du, Liang
    Wei, Maoling
    Liu, Yi
    OPHTHALMOLOGY, 2008, 115 (05) : 830 - 838
  • [40] KERATOMETRIC CYLINDER AND VISUAL PERFORMANCE FOLLOWING PHACOEMULSIFICATION AND IMPLANTATION WITH SILICONE SMALL-INCISION OR POLY(METHYL METHACRYLATE) INTRAOCULAR LENSES
    BRINT, SF
    OSTRICK, DM
    BRYAN, JE
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1991, 17 (01): : 32 - 36