Comparison of the NucliSENS EasyQ HIV-1 v2.0 with Abbott m2000rt RealTime HIV-1 assay for plasma RNA quantitation in different HIV-1 subtypes

被引:10
|
作者
Gomes, Perpetua [1 ,2 ,3 ]
Carvalho, Ana Patricia [1 ]
Diogo, Isabel [1 ]
Goncalves, Fatima [1 ]
Costa, Ines [1 ]
Cabanas, Joaquim [1 ]
Camacho, Ricardo Jorge [1 ,3 ]
机构
[1] Hosp Egas Moniz, Ctr Hosp Lisboa Ocidental, Mol Biol Lab, Serv Med Transfus, P-1349019 Lisbon, Portugal
[2] Inst Super Ciencias Saude Egas Moniz, Ctr Invest Interdisciplinar Egas Moniz, Monte De Caparica, Portugal
[3] Univ Nova Lisboa, Inst Higiene & Med Trop, Ctr Malaria & Outras Doencas Tropicais, P-1200 Lisbon, Portugal
关键词
HIV-1; EasyQ HIV-1; m2000; Subtypes; AMPLIPREP/COBAS TAQMAN HIV-1; NON-B SUBTYPES; VIRAL LOAD ASSAYS; VIRUS; RECOMBINANT; PERFORMANCE; INFECTION; CHINA; PANEL; V1.2;
D O I
10.1016/j.jviromet.2013.05.001
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Quantitation of HIV-1 RNA levels in plasma has significant prognostic value since high viral load concentrations in plasma are associated with a faster disease progression. Viral load testing became one the most important tools for monitoring HIV patients. New real time methodologies to quantify HIV viral load had arisen in the last decade. HIV is a virus with a high genetic variability, with the potential to negatively affect the performance of the viral load assays. Consequently, any new assay should be challenged against, at least, the most prevalent HIV-1 genetic variants. In the present study, the new version of NucliSENS EasyQ (R) HIV-1 (Version 2.0) quantitative assay was compared with another ultra-sensitive test - Abbott RealTime HIV-1 - using 175 plasma samples from patients infected with several HIV-1 subtypes and recombinant forms: subtype B (41, 23%), subtype C (19, 11%), subtype G (76, 44%), and CRF02_AG (39, 22%). Overall, there was agreement between the assays in 95.43% of the samples. Both assays have a very good dynamic range [1.4-6.9] and [1.60-7.0] log(10) copies/mL and excellent correlation in samples with various subtypes. Based on the fact that no clinically significant differences were observed in the viral load measurements by these two assays, HIV-1 subtypes are quantified equally by both assays. However due to HIV diversity, mainly in regions were non B subtypes are predominant more evaluations are needed, so we do not recommend to switch platform during longitudinal viral load monitoring. (c) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:18 / 22
页数:5
相关论文
共 50 条
  • [31] Comparative RNA Quantification of HIV-1 Group M and Non-M With the Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 v2.0 and Abbott Real-Time HIV-1 PCR Assays
    Sire, Jean-Marie
    Vray, Muriel
    Merzouk, Mourad
    Plantier, Jean-Christophe
    Pavie, Juliette
    Maylin, Sarah
    Timsit, Julie
    Lascoux-Combe, Caroline
    Molina, Jean-Michel
    Simon, Francois
    Delaugerre, Constance
    JAIDS-JOURNAL OF ACQUIRED IMMUNE DEFICIENCY SYNDROMES, 2011, 56 (03) : 239 - 243
  • [32] Efficient Quantification of HIV-1 in Heparin Plasma Spiked with Cultured HIV-1 by the Roche Cobas TaqMan and Abbott RealTime HIV-1 Tests
    Jagodzinski, Linda L.
    Weston, Holly R.
    Liu, Ying
    O'Connell, Robert J.
    Peel, Sheila A.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2012, 50 (08) : 2804 - 2806
  • [33] Comparison of Abbott RealTime HIV-1 and Roche COBAS® AmpliPrep/COBAS® TaqMan® HIV-1 Assays
    Abravaya, K.
    Hackett, J.
    Swanson, P.
    Huang, S.
    Tang, N.
    Robinson, J.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2008, 10 (06): : 587 - 587
  • [34] Evaluation of the Abbott m2000rt RealTime™ HIV-1 assay with manual sample preparation compared with the ROCHE COBAS® AmpliPrep™/AMPLICOR™ HIV-1 MONITOR® v1.5 using specimens from East Africa
    Crump, John A.
    Scott, Lesley E.
    Msuya, Emma
    Morrissey, Anne B.
    Kimaro, Ekyafyose E.
    Shao, John F.
    Stevens, Wendy S.
    JOURNAL OF VIROLOGICAL METHODS, 2009, 162 (1-2) : 218 - 222
  • [35] Evaluation of the Abbott m2000 RealTime Human Immunodeficiency Virus Type 1 (HIV-1) Assay for HIV Load Monitoring in South Africa Compared to the Roche Cobas AmpliPrep-Cobas Amplicor, Roche Cobas AmpliPrep-Cobas TaqMan HIV-1, and BioMerieux NucliSENS EasyQ HIV-1 Assays
    Scott, Lesley E.
    Noble, Lara D.
    Moloi, Jackie
    Erasmus, Linda
    Venter, Willem D. F.
    Stevens, Wendy
    JOURNAL OF CLINICAL MICROBIOLOGY, 2009, 47 (07) : 2209 - 2217
  • [36] RNA versus DNA (NucliSENS EasyQ HIV-1 v1.2 versus Amplicor HIV-1 DNA Test v1.5) for Early Diagnosis of HIV-1 Infection in Infants in Senegal
    Kebe, K.
    Ndiaye, O.
    Ndiaye, H. Diop
    Mengue, P. Mbakob
    Guindo, P. M. M.
    Diallo, S.
    Leye, N.
    Gueye, S. B.
    Diallo, A. Gaye
    Kane, C. Toure
    Mboup, S.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2011, 49 (07) : 2590 - 2593
  • [37] Field evaluation of an open and polyvalent universal HIV-1/SIVcpz/SIVgor quantitative RT-PCR assay for HIV-1 viral load monitoring in comparison to Abbott RealTime HIV-1 in Cameroon
    Guichet, Emilande
    Aghokeng, Avelin
    Eymard-Duvernay, Sabrina
    Vidal, Nicole
    Ayouba, Ahidjo
    Ngole, Eitel Mpoudi
    Delaporte, Eric
    Ciaffi, Laura
    Peeters, Martine
    JOURNAL OF VIROLOGICAL METHODS, 2016, 237 : 121 - 126
  • [38] Validation of Abbott Realtime HIV-1 Assay on Serum Samples
    Patel, M.
    Baltadjieva, B.
    Mihalov, M.
    Mazur, L.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2014, 16 (06): : 731 - 731
  • [39] Comparison between the automated Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 test version 2.0 assay and its version 1 and Nuclisens HIV-1 EasyQ version 2.0 assays when measuring diverse HIV-1 genotypes in China
    Xu, Sihong
    Song, Aijing
    Nie, Jianhui
    Li, Xiuhua
    Meng, Shufang
    Zhang, Chuntao
    Wang, Youchun
    JOURNAL OF CLINICAL VIROLOGY, 2012, 53 (01) : 33 - 37
  • [40] Dried blood spots versus plasma for the quantitation of HIV-1 RNA using a real-Time PCR, m2000rt assay
    Vidya, Madhavan
    Saravanan, Shanmugam
    Rifkin, Samara
    Solomon, Sunil S.
    Waldrop, Greer
    Mayer, Kenneth H.
    Solomon, Suniti
    Balakrishnan, Pachamuthu
    JOURNAL OF VIROLOGICAL METHODS, 2012, 181 (02) : 177 - 181