Load characteristics and operation strategies of building integrated with multi-story double skin facade

被引:46
|
作者
Joe, Jaewan [1 ]
Choi, Wonjun [1 ]
Kwon, Hansol [1 ]
Huh, Jung-Ho [1 ]
机构
[1] Univ Seoul, Dept Architectural Engn, Seoul 130743, South Korea
关键词
Multi-story double skin facades; Airflow network; Measurement and verification; EnergyPlus; BEMS; Operation strategies; NATURAL VENTILATION;
D O I
10.1016/j.enbuild.2013.01.015
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study measured an actual behavior of a multi-story double skin facade (DSF) in South Korea. The verification of simulation model was made against measured data, and a case study was conducted based on the verified model. Seasonal load characteristics of the DSF building were examined in comparison with the single skin facade (SSF) building, and seasonal operation strategies of the DSF were proposed. The DSF building resulted in 15.8% and 7.2% reductions in heating and cooling energy consumption respectively, compared to the SSF building. In the proposed model of heating seasons, heated air in the cavity was introduced to an outdoor air (OA) mixing box of a HVAC system. In the proposed model of cooling seasons, air in the cavity was flowed into an indoor space through inner layer openings for natural ventilation, and outdoor air supply in a AHU was controlled based on the amount of the natural ventilation. These seasonal proposed models resulted in 28.2% and 2.3% reductions in heating and cooling energy consumption respectively, compared to the DSF model to which operation strategies were not applied. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:185 / 198
页数:14
相关论文
共 50 条
  • [31] Earthquake disaster prediction of multi-story masonry building in Yinchuan City
    Tang, Shaorong
    PROGRESS IN INDUSTRIAL AND CIVIL ENGINEERING, PTS. 1-5, 2012, 204-208 : 2524 - 2527
  • [32] MODAL CHARACTERISTICS. OF PLANAR MULTI-STORY FRAME STRUCTURES
    Lin, H-P.
    Chang, S-C.
    Chu, C.
    JOURNAL OF MECHANICS, 2016, 32 (05) : 501 - 514
  • [33] Multi-zone simulation of outdoor particle penetration and transport in a multi-story building
    Lee, Byung Hee
    Yee, Su Whan
    Kang, Dong Hwa
    Yeo, Myoung Souk
    Kim, Kwang Woo
    BUILDING SIMULATION, 2017, 10 (04) : 525 - 534
  • [34] Climatic based consideration of Double Skin Facade system-comparative analysis of energy performance of a Double Skin Facade Building in Boston
    Azarbayjani, Mona
    Mehta, Jigisha
    SYMPOSIUM ON SIMULATION FOR ARCHITECTURE AND URBAN DESIGN 2012 (SIMAUD 2012), 2012, 44 (08): : 106 - 113
  • [35] Multi-zone simulation of outdoor particle penetration and transport in a multi-story building
    Byung Hee Lee
    Su Whan Yee
    Dong Hwa Kang
    Myoung Souk Yeo
    Kwang Woo Kim
    Building Simulation, 2017, 10 : 525 - 534
  • [36] Modal response characteristics of a seismic control multi-Story shear building using a tuned viscous mass damper
    Ikago, K.
    Sugimura, Y.
    Saito, K.
    Inoue, N.
    Civil-Comp Proceedings, 2013, 102
  • [37] Experimental research of the thermal characteristics of a multi-storey naturally ventilated double skin facade
    Andelkovic, Aleksandar S.
    Gvozdenac-Urosevic, Branka
    Kljajic, Miroslav
    Ignjatovic, Marko G.
    ENERGY AND BUILDINGS, 2015, 86 : 766 - 781
  • [38] Blast-load-induced interaction between adjacent multi-story buildings
    Mahmoud, Sayed
    EARTHQUAKES AND STRUCTURES, 2019, 17 (01) : 17 - 29
  • [39] Multi-story building damage localization based on sensitivity analysis of modal parameters
    Zhu, Hongping
    Zhou, Jianfeng
    Zhendong Ceshi Yu Zhenduan/Journal of Vibration, Measurement and Diagnosis, 2005, 25 (04): : 256 - 259
  • [40] Cost-optimum analysis of building fabric renovation in a Swedish multi-story residential building
    Bonakdar, Farshid
    Dodoo, Ambrose
    Gustavsson, Leif
    ENERGY AND BUILDINGS, 2014, 84 : 662 - 673