Cost-optimum analysis of building fabric renovation in a Swedish multi-story residential building

被引:46
|
作者
Bonakdar, Farshid [1 ]
Dodoo, Ambrose [1 ]
Gustavsson, Leif [1 ]
机构
[1] Linnaeus Univ, Fac Technol, SE-35195 Vaxjo, Sweden
关键词
Building renovation; Building fabric; Energy simulation; Space heating; Insulation; Energy efficiency; Cost-optimum renovation; Sustainability; Windows; LIFE-CYCLE; ENERGY;
D O I
10.1016/j.enbuild.2014.09.003
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this study, we analysed the cost-optimum level of building fabric elements renovation in a multi-story residential building. We calculated final energy use for space heating of the building considering a wide range of energy efficiency measures, for exterior walls, basement walls, attic floor and windows. Different extra insulation thicknesses for considered opaque elements and different U-values for new windows were used as energy efficiency measures. We calculated difference between the marginal saving of energy cost for space heating and the investment cost of implemented energy efficiency measures, in order to find the cost-optimum measure for each element. The implications of building lifespans, annual energy price increase and discount rate on the optimum measure were also analysed. The results of the analysis indicate that the contribution of energy efficiency measures to the final energy use reduces, significantly, by increasing the thickness of extra insulation and by reducing the U-value of new windows. We considered three scenarios of business as usual (BAU), intermediate and sustainability, considering different discount rates and energy price increase. The results of this analysis suggest that the sustainability scenario may offer, approximately, 100% increase in the optimum thickness of extra insulation compared to BAU scenario. However, the implication of different lifespans of 40, 50 or 60 years, on the optimum measure appears to be either negligible or very small, depending on the chosen scenario. We also calculated the corresponding U-value of the optimum measures in order to compare them with the current Swedish building code requirements and passive house criteria. The results indicate that all optimum measures meet the Swedish building code. None of the optimum measures, however, meet the passive house criteria in BAU scenario. This study suggests that the employed method of building renovation cost-optimum analyses can be also applied on new building construction to find the cost-optimum design from energy conservation point of view. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:662 / 673
页数:12
相关论文
共 50 条
  • [1] Economic analysis of multi-story light-gauge steel residential building
    Qin, Weihong
    Wang, Qunyi
    Liu, Lingli
    Wang, Henghua
    ISISS 2005: Innovation & Sustainability of Structures, Vol 1-3, 2005, : 663 - 674
  • [2] Settlement Response of a Multi-Story Building
    Bhutto, Amjad Hussain
    Bhurgri, Ghulam Shabir
    Zardari, Shahnawaz
    Zardari, Muhammad Auchar
    Memon, Bashir Ahmed
    Babar, Muhammad Munir
    ENGINEERING TECHNOLOGY & APPLIED SCIENCE RESEARCH, 2020, 10 (05) : 6220 - 6223
  • [3] RSSI Evaluation for Multi-story Building
    Dama, Y. A. S.
    Masri, Ahmed
    Ghannam, Hidaya
    Shuaieb, W.
    Alhassan, H.
    Obeidat, H. A.
    Abd-Alhameed, R. A.
    2015 INTERNET TECHNOLOGIES AND APPLICATIONS (ITA) PROCEEDINGS OF THE SIXTH INTERNATIONAL CONFERENCE (ITA 15), 2015, : 414 - 416
  • [4] Comparative Cost Analysis of Possible Seismic Retrofitting Schemes for Multi-Story Unreinforced Masonry Building
    Roy, Sushanta
    Khan, Md. Shahriar Rahman
    Ahmad, Syed Ishtiaq
    2ND INTERNATIONAL CONFERENCE ON REHABILITATION AND MAINTENANCE IN CIVIL ENGINEERING (ICRMCE), 2013, 54 : 584 - 590
  • [5] Floor Determination for Positioning in Multi-story Building
    Abd Rahman, Mohd Amiruddin
    Dashti, Marzieh
    Zhang, Jie
    2014 IEEE WIRELESS COMMUNICATIONS AND NETWORKING CONFERENCE (WCNC), 2014, : 2540 - 2545
  • [6] Analysis of a multi-story reinforced concrete residential building damaged under its self-weight
    Korkmaz, Hasan Husnu
    Yakut, Ahmet
    Bayraktar, Atilla
    ENGINEERING FAILURE ANALYSIS, 2019, 98 : 38 - 48
  • [7] Applying steel eccentrically braced frame with long links in multi-story residential building
    Liu, GQ
    Shi, YJ
    Wang, YQ
    Hong, C
    Yong, Z
    PROCEEDINGS OF THE SEVENTH INTERNATIONAL SYMPOSIUM ON STRUCTURAL ENGINEERING FOR YOUNG EXPERTS, VOLS 1 AND 2, 2002, : 220 - 223
  • [8] Multi-objective optimization of the multi-story residential building with passive design strategy in South Korea
    Jung, Yujun
    Heo, Yeonsook
    Lee, Hoseong
    BUILDING AND ENVIRONMENT, 2021, 203
  • [9] Analysis on the Exhaust Air Recirculation of the Ventilation System in Multi-Story Building
    Park, Seonghyun
    Park, Hyungyu
    Seo, Janghoo
    APPLIED SCIENCES-BASEL, 2021, 11 (10):
  • [10] Seismic Design and Analysis of a Cold-Formed Steel Exoskeleton for the Retrofit of an RC Multi-Story Residential Building
    Meglio, Emilia
    Formisano, Antonio
    APPLIED SCIENCES-BASEL, 2024, 14 (19):