Influence of Implant Design and Under-Preparation of the Implant Site on Implant Primary Stability. An In Vitro Study

被引:24
|
作者
Herrero-Climent, Mariano [1 ]
Lemos, Bernardo Ferreira [1 ,2 ]
Herrero-Climent, Federico [3 ]
Falcao, Carlos [1 ,2 ]
Oliveira, Helder [2 ]
Herrera, Manuela [4 ]
Javier Gil, Francisco [5 ]
Rios-Carrasco, Blanca [6 ]
Rios-Santos, Jose-Vicente [6 ]
机构
[1] Porto Dent Inst, P-4150518 Porto, Portugal
[2] Fernando Pessoa Univ, Fac Hlth Sci, P-4249004 Porto, Portugal
[3] Univ Complutense Madrid, Dept Periodontol, Madrid 28040, Spain
[4] Univ Seville, Dept Stomatol, Seville 41009, Spain
[5] Univ Int Catalunya, Fac Dent, Barcelona 08017, Spain
[6] Univ Seville, Dept Periodontol, Seville 41009, Spain
关键词
dental implant; tapered; under-preparation; implant preparation; implant stability; insertion torque; ISQ; RFA; RESONANCE FREQUENCY-ANALYSIS; LOW-DENSITY BONE; DENTAL IMPLANTS; SURGICAL TECHNIQUE; SURFACE-ROUGHNESS; STEPPED OSTEOTOMY; INSERTION TORQUE; HUMAN CADAVERS; OSSEOINTEGRATION; RELIABILITY;
D O I
10.3390/ijerph17124436
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The aim of this study was to evaluate the effects of different implant sites an under-preparation sequence associated with two different implant designs on implant primary stability measured by two parameters: insertion torque (IT) and implant stability quotient (ISQ). It used two different implants: one cylindrical as a control and another one with a tapered design. The implants were inserted in type III fresh humid bovine bone and four drilling sequences were used: one control, the one proposed by the implant company (P1), and three different undersized (P2, P3 and P4). P2 was the same as P1 without the cortical drill, P3 was without the last pilot drill and P4 was without both of them. The sample size wasn= 40 for each of the eight groups. Final IT was measured with a torquemeter and the ISQ was measured with Penguin resonance frequency analysis. Results showed that both ISQ and IT have a tendency to increase as the preparation technique reduces the implant site diameter when compared with the standard preparation, P1. The preparations without cortical drill, P2 and P4, showed the best results when compared with the ones with a cortical drill. Tapered implants always showed higher or the same ISQ and IT values when compared with the cylindrical implants. Giving the limitations of this study, it can be concluded that reducing implant preparation can increase IT and ISQ values. Removing the cortical drill and the use of a tapered design implant are also effective methods of increasing primary implant stability.
引用
收藏
页码:1 / 13
页数:13
相关论文
共 50 条
  • [41] Compromised Primary Implant Stability
    Queiroz, Thallita Pereira
    Souza, Francisley Avila
    Okamoto, Roberta
    Luvizuto, Eloa Rodrigues
    Margonar, Rogerio
    Garcia, Idelmo Rangel, Jr.
    Vieira, Eduardo Hochuli
    JOURNAL OF CRANIOFACIAL SURGERY, 2012, 23 (05) : E524 - E528
  • [42] Influence of peri-implant bone quality on implant stability
    Schiuma, Damiano
    Plecko, Michael
    Kloub, Martin
    Rothstock, Stephan
    Windolf, Markus
    Gueorguiev, Boyko
    MEDICAL ENGINEERING & PHYSICS, 2013, 35 (01) : 82 - 87
  • [43] Prosthetic Surgical Templates and Dental Implant Site Time Preparation: An In Vitro Study
    Zadrozny, Lukasz
    Czajkowska, Marta
    Tallarico, Marco
    Wagner, Leopold
    Markowski, Jaroslaw
    Mijiritsky, Eitan
    Cicciu, Marco
    PROSTHESIS, 2022, 4 (01): : 25 - 37
  • [44] A new implant design: Implant stability and success at uncovering.
    Kanaan, A
    Morris, H
    Ochi, S
    Plezia, R
    Barnes, D
    Solomon, R
    Howe, A
    JOURNAL OF DENTAL RESEARCH, 1998, 77 : 661 - 661
  • [45] Influence of Implant Thread Morphology on Primary Stability: A Prospective Clinical Study
    Menini, Maria
    Bagnasco, Francesco
    Calimodio, Ivan
    Di Tullio, Nicolo
    Delucchi, Francesca
    Baldi, Domenico
    Pera, Francesco
    BIOMED RESEARCH INTERNATIONAL, 2020, 2020
  • [46] Influence of implant neck and abutment characteristics on peri-implant tissue health and stability. Oral reconstruction foundation consensus report
    Schwarz, Frank
    Messias, Ana
    Sanz-Sanchez, Ignacio
    Carrillo de Albornoz, Ana
    Nicolau, Pedro
    Taylor, Tom
    Beuer, Florian
    Schaer, Alex
    Sader, Robert
    Guerra, Fernando
    Sanz, Mariano
    CLINICAL ORAL IMPLANTS RESEARCH, 2019, 30 (06) : 588 - 593
  • [47] Effect of Guiding Sleeve Design on Intraosseous Heat Generation During Implant Site Preparation (In Vitro Study)
    Ashry, Amal
    Elattar, Mohamed Sherine
    Elsamni, Osama Ahmed
    Soliman, Ingy Saied
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (02): : 147 - 154
  • [48] Use of Osteotomes for Implant Bed Preparation-Effect on Material Properties of Bone and Primary Implant Stability
    Krafft, Tim
    Graef, Friedrich
    Winter, Werner
    Wichmann, Manfred
    Karl, Matthias
    JOURNAL OF ORAL IMPLANTOLOGY, 2013, 39 : 241 - 247
  • [49] Correlation Between Implant Geometry, Implant Surface, Insertion Torque, and Primary Stability: In Vitro Biomechanical Analysis
    Falco, Antonello
    Berardini, Marco
    Trisi, Paolo
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (04) : 824 - 830
  • [50] Influence of acetabular cup design on the primary implant stability - An experimental and numerical analysis
    Zietz, C.
    Fritsche, A.
    Kluess, D.
    Mittelmeier, W.
    Bader, R.
    ORTHOPADE, 2009, 38 (11): : 1097 - +