Voltammetric sensing performances of a carbon ionic liquid electrode modified with black phosphorene and hemin

被引:28
|
作者
Li, Xiaoyan [1 ]
Luo, Guiling [1 ]
Xie, Hui [1 ]
Niu, Yanyan [1 ]
Li, Xiaobao [1 ]
Zou, Ruyi [1 ]
Xi, Yaru [1 ]
Xiong, Yi [1 ]
Sun, Wei [1 ]
Li, Guangjiu [2 ]
机构
[1] Hainan Normal Univ, Coll Chem & Chem Engn, Key Lab Funct Mat & Photoelectrochem Haikou, Key Lab Laser Technol & Optoelect Funct Mat Haina, Haikou 571158, Hainan, Peoples R China
[2] Qingdao Univ Sci & Technol, Coll Chem & Mol Engn, Minist Educ, Key Lab Opt Elect Sensing & Analyt Chem Life Sci, Qingdao 266042, Shandong, Peoples R China
基金
中国国家自然科学基金;
关键词
Black phosphorene; Hemin; Electrochemical biosensor; Electrocatalytic effect; Poly(3; 4-ethylenedioxythiophene)-poly(styrenesulfonate); Carbon ionic liquid electrode; Direct electrochemistry; Trichloroacetic acid; Nitrite; Hydrogen peroxide; NANOCOMPOSITE MODIFIED ELECTRODE; DIRECT ELECTROCHEMISTRY; HORSERADISH-PEROXIDASE; GRAPHENE OXIDE; ELECTROCATALYSIS; MYOGLOBIN; HEMOGLOBIN; BIOSENSOR; TRANSISTORS; FILM;
D O I
10.1007/s00604-019-3421-x
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A black phosphorene (BPE) and poly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate) (PEDOT:PSS) hybrid was used for the immobilization of hemin on acarbon ionic liquid electrode (CILE). BPE inside thePEDOT:PSS film was stable without adverse effects of water and oxygen. The hemin-modified electrode facilitates electrochemical communication with a couple of well-shaped and enhanced redox waves. Therefore BPE exhibits an accelerating function to the electron movement. This sensor exhibits excellent electrocatalytic effects on the reduction of various substrates including trichloroacetic acid (TCA), nitrite and H2O2. As for TCA, the reduction current at -0.36V (vs. Ag/AgCl) increases linearly in the concentrationrange from 2.0 to 180mmolL(-1) with a detection limit of 0.67mmolL(-1) (at 3 sigma). As for nitrite, the reduction current at -0.59Vis linear in the1.0 to 10.5mmolL(-1) concentration range,and the detection limit is 0.33mmolL(-1) (at 3 sigma). As for H2O2, the reduction current at -0.033V (vs. Ag/AgCl) is linear in the concentration rangefrom 4.0 to 35.0mmolL(-1) and the detection limit is 1.3mmolL(-1) (at 3 sigma). The real sample was analyzed with satisfactory results, which indicated that BPE had potential applications in the field of electrochemical biosensor.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Sensitive Voltammetric Determination of Cadmium(II) with 8-Hydroxyquinoline and Ionic Liquid Modified Carbon Paste Electrode
    Jia, Shaohui
    Gong, Shixing
    Cheng, Yong
    Wang, Huiyun
    Liu, Hejian
    Zhang, Bo
    Sun, Wei
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2014, 61 (11) : 1217 - 1222
  • [32] Sensitive Voltammetric Detection of Indomethacin Using TiO2 Nanoparticle Modified Carbon Ionic Liquid Electrode
    Baezzat, Mohammad Reza
    Banavand, Fatemeh
    Hakkani, Sedigheh Kamran
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY RESEARCH, 2020, 7 (01): : 89 - 98
  • [33] Sensitive voltammetric determination of epinephrine in the presence of acetaminophen at a novel ionic liquid modified carbon nanotubes paste electrode
    Tavana, Toktam
    Khalilzadeh, Mohammad A.
    Karimi-Maleh, Hassan
    Ensafi, Ali A.
    Beitollahi, Hadi
    Zareyee, Daryoush
    JOURNAL OF MOLECULAR LIQUIDS, 2012, 168 : 69 - 74
  • [34] Voltammetric Determination of Metrafenone Using an Iridium Oxide Nanoparticle - Ionic Liquid Nanocomposite Modified Glassy Carbon Electrode
    Celik, Murat
    Bozal-Palabiyik, Burcin
    Kanbes Dindar, Cigdem
    Uslu, Bengi
    ANALYTICAL LETTERS, 2024,
  • [35] Voltammetric determination of xanthine with a single-walled carbon nanotube-ionic liquid paste modified glassy carbon electrode
    Xiao, Fei
    Ruan, Changping
    Li, Jiangwen
    Liu, Lihong
    Zhao, Faqiong
    Zeng, Baizhao
    ELECTROANALYSIS, 2008, 20 (04) : 361 - 366
  • [36] Sensitive voltammetric method for the determination of naproxen at the surface of carbon nanofiber/gold/polyaniline nanocomposite modified carbon ionic liquid electrode
    Afzali, Moslem
    Jahromi, Zahra
    Nekooie, Reyhaneh
    MICROCHEMICAL JOURNAL, 2019, 145 : 373 - 379
  • [37] Enhanced voltammetric determination of dopamine using a glassy carbon electrode modified with ionic liquid-functionalized graphene and carbon dots
    Xuming Zhuang
    Haihua Wang
    Tao He
    Lingxin Chen
    Microchimica Acta, 2016, 183 : 3177 - 3182
  • [38] Simultaneous Voltammetric Determination of Theophylline and Guaifenesin Using a Multiwalled Carbon Nanotube-Ionic Liquid Modified Glassy Carbon Electrode
    Gholivand, Mohammad Bagher
    Khodadadian, Mehdi
    ELECTROANALYSIS, 2014, 26 (09) : 1975 - 1983
  • [39] Enhanced voltammetric determination of dopamine using a glassy carbon electrode modified with ionic liquid-functionalized graphene and carbon dots
    Zhuang, Xuming
    Wang, Haihua
    He, Tao
    Chen, Lingxin
    MICROCHIMICA ACTA, 2016, 183 (12) : 3177 - 3182
  • [40] Reinforced Rubber with Ionic Liquid Modified Carbon Black
    Lei, Yanda
    Guo, Baochun
    Liu, Xiaoliang
    Jia, Demin
    POLYMERS & POLYMER COMPOSITES, 2011, 19 (07): : 593 - 601